{"product_id":"activadose-ii-dose-controller-system","title":"ActivaDose II Iontophoresis Dose Controller | 0–80 mA·min","description":"\u003ch2\u003eActivaDose® II Professional Iontophoresis Dose Controller\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eActivaDose II Iontophoresis Delivery Unit\u003c\/strong\u003e is a reusable, prescription dose controller designed for clinician-directed administration of soluble salts and other appropriate medications through intact skin using controlled direct current.\u003c\/p\u003e\n\u003cp\u003eThe practitioner selects the prescribed dose in milliampere-minutes, or mA·min, and sets the treatment current. ActivaDose II then calculates the required treatment time automatically and adjusts the remaining time if the current is changed or treatment is paused.\u003c\/p\u003e\n\u003cp\u003eA high-contrast display shows dose, actual current, and time remaining. Automatic current ramp-up and ramp-down, resistance monitoring, electrode-reject protection, limit indicators, and audible alerts help support a controlled professional treatment workflow.\u003c\/p\u003e\n\u003cp\u003eThe controller operates on one replaceable 9V alkaline battery and is supplied with two lead wires, two 9V batteries, and an operating manual. Disposable iontophoresis electrodes and medication are sold separately. \u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThis device to sale by or on the order of a physician or appropriately licensed practitioner. Medication selection, polarity, dose, current, electrode choice, placement, and patient monitoring require professional direction.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eProfessional single-channel iontophoresis controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActivaTek model 001-48\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNorth Coast Medical item NC89186\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFDA-cleared prescription medical device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable dose from 0–80 mA·min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFine 0.1 mA·min dose increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable current up to 4.0 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent adjustments in 0.1 mA increments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum output of 80 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic treatment-time calculation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic time recalculation after current changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePause-and-resume function retains delivered dose\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGradual automatic current ramp-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic ramp-down at treatment completion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManual current-ramp option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-contrast dose, current, and time display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance-limit monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent- and dose-limit alerts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode-reject safety function\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-battery warnings and battery-reject protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic shutoff after approximately one minute of inactivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLightweight 0.4-pound design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne-year manufacturer device warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for use with compatible professional iontophoresis electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActivaTek lists the 0–80 mA·min dose range, 0.1 mA·min increments, automatic ramping, 80 V maximum output, visual and audible alerts, and one-year warranty. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eQuick specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eActivaDose II detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eActivaDose® II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eActivaTek, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e001-48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth Coast Medical SKU\u003c\/td\u003e\n\u003ctd\u003eNC89186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego reference\u003c\/td\u003e\n\u003ctd\u003eII-DOSE-CONTROLLER-SYSTEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePrescription iontophoresis delivery unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel format\u003c\/td\u003e\n\u003ctd\u003eSingle channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eDirect current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose range\u003c\/td\u003e\n\u003ctd\u003e0–80 mA·min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose adjustment\u003c\/td\u003e\n\u003ctd\u003e0.1 mA·min increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault startup dose\u003c\/td\u003e\n\u003ctd\u003e40.0 mA·min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range\u003c\/td\u003e\n\u003ctd\u003e0–4.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent adjustment\u003c\/td\u003e\n\u003ctd\u003e0.1 mA increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e80 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime calculation\u003c\/td\u003e\n\u003ctd\u003eAutomatic from selected dose and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDose, current, and remaining treatment time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePause function\u003c\/td\u003e\n\u003ctd\u003eYes, it retains delivered dose and recalculates time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent ramp-up\u003c\/td\u003e\n\u003ctd\u003eAutomatic, with manual adjustment available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent ramp-down\u003c\/td\u003e\n\u003ctd\u003eAutomatic at completion or certain stop conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety monitoring\u003c\/td\u003e\n\u003ctd\u003eResistance, dose, current, electrode circuit, and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical classification\u003c\/td\u003e\n\u003ctd\u003eType BF applied part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating mode\u003c\/td\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.1 × 3.5 × 1.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetric dimensions\u003c\/td\u003e\n\u003ctd\u003e15.5 × 8.9 × 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 lb \/ 0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eOne 9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable battery permitted\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater protection\u003c\/td\u003e\n\u003ctd\u003eNot protected against water ingress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eOne year on controller; accessories excluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposable electrodes included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhat comes with ActivaDose II?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded item\u003c\/th\u003e\n\u003cth align=\"right\"\u003eQuantity\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eActivaDose II controller\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eControls current, dose, and treatment time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIontophoresis lead wires\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eConnect the controller to compatible active and return electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9V alkaline batteries\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eOne operating battery plus a replacement\/spare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstruction manual\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eSetup, operation, safety, and troubleshooting guidance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe controller uses one 9V alkaline battery at a time. The manual specifically says not to use rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePrescription medication or solution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive drug-delivery electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispersive or return electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlcohol prep pads, except when supplied with a separately purchased electrode kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCarrying case unless specifically included in the current Balego package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePair the controller with \u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion Iontophoresis Delivery Kits\u003c\/a\u003e or another compatible controller-based electrode system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow ActivaDose II calculates an iontophoresis dose\u003c\/h1\u003e\n\u003cp\u003eAn iontophoresis dose is expressed in \u003cstrong\u003emA·min\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent in milliamps × treatment time in minutes = dose in mA·min\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAfter the clinician selects the dose and current, ActivaDose II calculates the treatment time automatically.\u003c\/p\u003e\n\u003ch2\u003eExample treatment-time calculations\u003c\/h2\u003e\n\u003ch3\u003e40 mA·min dose\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eSelected current\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCalculated time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.5 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e16 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e3.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e13 minutes 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e80 mA·min dose\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eSelected current\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCalculated time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e80 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.5 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e32 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e3.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e26 minutes 40 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4.0 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese examples illustrate the mathematics only. The correct dose and current must come from the medication order, electrode instructions, treatment location, skin condition, patient tolerance, and clinical protocol. The manufacturer recommends lower current for sensitive anatomical sites, current-sensitive patients, and thin or fragile skin.\u003c\/p\u003e\n\u003ch2\u003eWhat happens when the current is reduced?\u003c\/h2\u003e\n\u003cp\u003eReducing current increases the remaining treatment time so the selected dose can still be delivered. For example, changing from 4 mA to 2 mA approximately doubles the time needed to deliver the same remaining mA·min dose.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eAutomatic treatment and safety functions\u003c\/h1\u003e\n\u003ch2\u003eAutomatic current ramp-up\u003c\/h2\u003e\n\u003cp\u003eWhen treatment begins, the current rises gradually toward the selected setting. The clinician can lower the current at any point if the patient reports discomfort.\u003c\/p\u003e\n\u003ch2\u003eAutomatic ramp-down\u003c\/h2\u003e\n\u003cp\u003eAfter the prescribed dose has been delivered, the controller gradually reduces current to zero and sounds an end-of-treatment alert.\u003c\/p\u003e\n\u003cp\u003eThe controller also ramps down before shutdown and during certain low-battery conditions.\u003c\/p\u003e\n\u003ch2\u003ePause and resume\u003c\/h2\u003e\n\u003cp\u003ePressing the current control—or reducing current to zero—pauses treatment. The device retains the dose already delivered.\u003c\/p\u003e\n\u003cp\u003eWhen treatment restarts, ActivaDose II recalculates the remaining time and ramps the current up again.\u003c\/p\u003e\n\u003ch2\u003eResistance limit\u003c\/h2\u003e\n\u003cp\u003eA high-resistance treatment site may prevent the device from reaching the selected current. The controller displays a resistance-limit warning while continuing at the highest achievable output and adjusting time as needed.\u003c\/p\u003e\n\u003ch2\u003eElectrode reject\u003c\/h2\u003e\n\u003cp\u003eThe electrode-reject system stops current if the device detects a break or unsuitable condition in the treatment circuit.\u003c\/p\u003e\n\u003cp\u003ePossible causes include the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLoose lead-wire connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode lifting from the skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry or poorly prepared skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsufficient medication or hydration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInappropriate medication formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncorrect electrode setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBroken or interrupted circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit beeps, flashes the reject indicator, displays an electrode-reject message, and turns off current.\u003c\/p\u003e\n\u003ch2\u003eBattery monitoring\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay or alert\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery indicator during treatment\u003c\/td\u003e\n\u003ctd\u003eThe battery is weakening but treatment may continue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery at startup\u003c\/td\u003e\n\u003ctd\u003eThe battery is too weak to begin treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Reject\u003c\/td\u003e\n\u003ctd\u003eThe battery cannot safely continue the current session\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo power\u003c\/td\u003e\n\u003ctd\u003eThe battery may be depleted, reversed, or improperly installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eTypical professional workflow\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer summarizes operation as three main actions:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eSelect dose.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSet current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStart treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA complete clinical workflow includes several additional safety steps:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eStep\u003c\/th\u003e\n\u003cth\u003eClinical action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eConfirm medication order, concentration, polarity, dose, current, and treatment site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eScreen for contraindications, allergies, implanted systems, and skin problems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd\u003eInspect the active- and return-electrode sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003ctd\u003ePrepare the drug electrode using its exact fill-volume instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e5\u003c\/td\u003e\n\u003ctd\u003eClean both skin sites and allow them to dry thoroughly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e6\u003c\/td\u003e\n\u003ctd\u003ePosition the active electrode over the prescribed treatment area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e7\u003c\/td\u003e\n\u003ctd\u003ePosition the return electrode over a suitable nearby muscle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e8\u003c\/td\u003e\n\u003ctd\u003eKeep the return electrode away from thin tissue and bony prominences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e9\u003c\/td\u003e\n\u003ctd\u003eConnect the leads and confirm correct medication polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e10\u003c\/td\u003e\n\u003ctd\u003eSelect dose and current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e11\u003c\/td\u003e\n\u003ctd\u003eStart treatment and monitor patient comfort, skin response, and display status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003ctd\u003ePause immediately if burning, sharp pain, or unusual discomfort occurs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e13\u003c\/td\u003e\n\u003ctd\u003eAllow the unit to ramp down when the dose is complete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e14\u003c\/td\u003e\n\u003ctd\u003eDisconnect, remove, and discard both single-use electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e15\u003c\/td\u003e\n\u003ctd\u003eDocument dose, current, time, medication, polarity, placement, and skin response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manual calls for intact skin, correct electrode fill volume, alcohol preparation followed by complete drying, and approximately 4–6 inches between the drug and dispersive electrodes when allowed by the electrode instructions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCompatible iontophoresis electrodes\u003c\/h1\u003e\n\u003cp\u003eThe controller must be paired with a compatible active drug electrode and return electrode. The disposable electrode instructions determine:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum permitted dose\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedication fill volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode polarity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydration requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSite preparation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode spacing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment-area suitability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eBalego electrode options\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePackage\u003c\/th\u003e\n\u003cth\u003eMain distinction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion Iontophoresis Delivery Kits\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eForm-fitting design for curved or uneven treatment areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ionto4-iontophoresis-electrodes\"\u003eIonto4 Iontophoresis Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eCarbon-Ag\/AgCl active and return electrode kits in four shapes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontophoresis-electrodes\"\u003eBalego Iontophoresis Electrode Kits\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMultiple sizes\u003c\/td\u003e\n\u003ctd\u003eAg\/AgCl drug electrode with buffered return electrode and prep pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iogel-iontophoresis-electrodes\"\u003eIOGEL Iontophoresis Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eTraditional controller-based IOMED electrode workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTrivarion is specifically designed for ActivaDose II and is available in small, medium, butterfly, and large formats. Ionto4 is designed for FDA-cleared constant-current iontophoresis devices and likewise provides multiple fill-volume and shape options. \u003c\/p\u003e\n\u003ch3\u003eTrivarion size guide\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth align=\"right\"\u003eFill volume\u003c\/th\u003e\n\u003cth\u003ePotential placement advantage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5 cc\u003c\/td\u003e\n\u003ctd\u003eSmaller, targeted, or narrow areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose treatment sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003eCurved, irregular, tendon, or joint contours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3.5 cc\u003c\/td\u003e\n\u003ctd\u003eBroader treatment areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe clinician must choose the electrode using the prescribed medication volume, anatomical site, dose, and electrode instructions—not size alone.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eActivaDose II vs. wearable iontophoresis patches\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\"\u003eActivaDose II\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eReusable external controller\u003c\/td\u003e\n\u003ctd\u003eSelf-contained disposable patch\u003c\/td\u003e\n\u003ctd\u003eSelf-contained disposable patch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead wires required\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate electrodes required\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo external electrode kit\u003c\/td\u003e\n\u003ctd\u003eNo external controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent selected by clinician\u003c\/td\u003e\n\u003ctd\u003eYes, up to 4 mA\u003c\/td\u003e\n\u003ctd\u003eControlled by patch design\u003c\/td\u003e\n\u003ctd\u003eControlled by patch design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose entered by clinician\u003c\/td\u003e\n\u003ctd\u003eYes, up to 80 mA·min\u003c\/td\u003e\n\u003ctd\u003eModel-specific 80 or 120 mA·min\u003c\/td\u003e\n\u003ctd\u003eModel-specific\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment time\u003c\/td\u003e\n\u003ctd\u003eCalculated from selected dose and current\u003c\/td\u003e\n\u003ctd\u003eLonger wearable delivery, model-dependent\u003c\/td\u003e\n\u003ctd\u003eWearable delivery, model-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe patient remains connected to the controller.\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic supervision during active, connected treatment\u003c\/td\u003e\n\u003ctd\u003eNormally, yes.\u003c\/td\u003e\n\u003ctd\u003ePatch can continue outside the clinic when directed\u003c\/td\u003e\n\u003ctd\u003ePatch can continue outside the clinic when directed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable equipment cost\u003c\/td\u003e\n\u003ctd\u003eController reused\u003c\/td\u003e\n\u003ctd\u003eNo controller investment\u003c\/td\u003e\n\u003ctd\u003eNo controller investment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumable cost\u003c\/td\u003e\n\u003ctd\u003eElectrode kit per treatment\u003c\/td\u003e\n\u003ctd\u003eComplete patch per treatment\u003c\/td\u003e\n\u003ctd\u003eComplete patch per treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eDirect current and dose control in a clinic\u003c\/td\u003e\n\u003ctd\u003eWearable, wire-free workflow\u003c\/td\u003e\n\u003ctd\u003eWearable options with different treatment-time profiles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe ActivaDose II gives the clinician direct control over current and dose while the patient remains connected to the unit. IontoPATCH and ACTIVApatch integrate the power source into a disposable patch and require no external controller or lead wires. \u003c\/p\u003e\n\u003ch2\u003eChoose ActivaDose II when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDirect clinician control of current is important.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants to set and document a precise mA·min dose.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA shorter connected treatment is preferred over extended patch wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe facility already uses controller-based electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA reusable controller is more economical for repeated clinic treatments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStaff are familiar with traditional Phoresor-style iontophoresis workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode shape and fill volume need to be selected for each treatment area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eActivaDose II vs. legacy IOMED Phoresor II\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eActivaDose II\u003c\/th\u003e\n\u003cth\u003eIOMED Phoresor II Auto PM850\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent market role\u003c\/td\u003e\n\u003ctd\u003eCurrent commercially distributed controller\u003c\/td\u003e\n\u003ctd\u003eLegacy\/discontinued controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA·min dose workflow\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable current\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic time calculation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eLegacy controller feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Balego availability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eReplacement rather than new sale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eClinics maintaining controller-based iontophoresis\u003c\/td\u003e\n\u003ctd\u003eExisting legacy installed base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe ActivaDose II is a \u003cstrong\u003ereplacement option for clinics transitioning from a Phoresor II workflow\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eOperating and storage conditions\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003cth\u003eManufacturer specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e41–104°F \/ 5–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport and storage\u003c\/td\u003e\n\u003ctd\u003e50–131°F \/ 10–55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003eLess than 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating altitude\u003c\/td\u003e\n\u003ctd\u003eApproximately 9,842 ft \/ 3,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater ingress protection\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammable environment\u003c\/td\u003e\n\u003ctd\u003eDo not use around flammable gases, liquids, or materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eAlcohol-moistened cloth on case and lead clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion\u003c\/td\u003e\n\u003ctd\u003eDo not immerse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eRemove the battery when the unit will not be used for an extended period.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTroubleshooting guide\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMessage or problem\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe unit does not turn on\u003c\/td\u003e\n\u003ctd\u003eDepleted, reversed, or improperly installed battery\u003c\/td\u003e\n\u003ctd\u003eInstall a fresh 9V alkaline battery with correct polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery\u003c\/td\u003e\n\u003ctd\u003eInsufficient battery voltage\u003c\/td\u003e\n\u003ctd\u003eReplace battery before treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Battery Reject\u003c\/td\u003e\n\u003ctd\u003eThe battery became too weak during treatment\u003c\/td\u003e\n\u003ctd\u003eReplace battery; the unit will not resume until corrected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Reject\u003c\/td\u003e\n\u003ctd\u003eLoose lead, lifting pad, dry skin, improper hydration, or unsuitable circuit\u003c\/td\u003e\n\u003ctd\u003ePause, inspect every connection and electrode, correct the cause, and restart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Limit\u003c\/td\u003e\n\u003ctd\u003eSkin or treatment-site resistance is too high\u003c\/td\u003e\n\u003ctd\u003eConfirm skin preparation and electrode contact; the unit adjusts current and time automatically\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose Limit\u003c\/td\u003e\n\u003ctd\u003eAttempt to exceed 80 mA·min\u003c\/td\u003e\n\u003ctd\u003eConfirm the prescribed dose and electrode IFU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limit\u003c\/td\u003e\n\u003ctd\u003eAttempt to exceed 4.0 mA\u003c\/td\u003e\n\u003ctd\u003eUse an allowed current and permit the device to recalculate time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient reports burning\u003c\/td\u003e\n\u003ctd\u003eHigh current density, poor contact, compression, damaged pad, or sensitive skin\u003c\/td\u003e\n\u003ctd\u003ePause immediately, inspect skin and electrodes, and discontinue when necessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe remaining time increases\u003c\/td\u003e\n\u003ctd\u003eThe current was lowered or the treatment was paused\u003c\/td\u003e\n\u003ctd\u003eNormal automatic recalculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent does not reach the setting.\u003c\/td\u003e\n\u003ctd\u003eHigh resistance or inadequate circuit\u003c\/td\u003e\n\u003ctd\u003eInspect skin, electrodes, medication hydration, leads, and placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeated rejects with fresh electrodes\u003c\/td\u003e\n\u003ctd\u003eLead-wire, device, medication, or setup issue\u003c\/td\u003e\n\u003ctd\u003eFollow the manual and contact qualified service if unresolved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe manufacturer’s troubleshooting section identifies loose connections, electrode lift, insufficient medication, improper hydration, inappropriate medication, high resistance, and low battery as common causes of alerts.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eImportant safety information\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNever reuse single-use electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not tape, bind, or compress electrodes against the skin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not use damaged or altered electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove jewelry that could contact either electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not disconnect electrodes while current is flowing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse lower current for fragile skin, sensitive sites, or current-sensitive patients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not exceed the limits specified by the controller, medication order, or electrode IFU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not immerse the controller or connect it to unauthorized external devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect and document the skin after treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is ActivaDose II?\u003c\/h2\u003e\n\u003cp\u003eActivaDose II is a reusable, microprocessor-controlled iontophoresis delivery unit that provides clinician-selected direct current and mA·min dose control for administration of appropriate soluble medications through intact skin.\u003c\/p\u003e\n\u003ch2\u003eIs ActivaDose II FDA-approved?\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/accessgudid.nlm.nih.gov\/devices\/00859975005011\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003eFDA cleared\u003c\/strong\u003e\u003c\/a\u003e. FDA records identify ActivaDose II as an iontophoresis device, model 001-48, currently in commercial distribution. \u003c\/p\u003e\n\u003ch2\u003eIs a prescription required?\u003c\/h2\u003e\n\u003cp\u003eYes. The manual states that federal law restricts the device to sale by or on the order of a physician.\u003c\/p\u003e\n\u003ch2\u003eWhat is the Balego SKU?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNC89186\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer model number?\u003c\/h2\u003e\n\u003cp\u003eThe ActivaTek model number is \u003ca href=\"https:\/\/accessgudid.nlm.nih.gov\/devices\/00859975005011\" target=\"_blank\" rel=\"noopener\"\u003e\u003cstrong\u003e001-48\u003c\/strong\u003e\u003c\/a\u003e. \u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum dose?\u003c\/h2\u003e\n\u003cp\u003eThe controller can be set from 0–80 mA·min in 0.1 mA·min increments. The disposable electrode instructions may specify a lower maximum for a particular electrode or setup. \u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum current?\u003c\/h2\u003e\n\u003cp\u003eMaximum current is 4.0 mA. Lower settings may be required for sensitive sites, fragile skin, current-sensitive patients, or particular electrodes.\u003c\/p\u003e\n\u003ch2\u003eWhat is the maximum voltage?\u003c\/h2\u003e\n\u003cp\u003eThe maximum output is 80 V DC.\u003c\/p\u003e\n\u003ch2\u003eDoes it calculate treatment time?\u003c\/h2\u003e\n\u003cp\u003eYes. Once dose and current are selected, the controller calculates treatment time automatically. It recalculates the remaining time after a pause or current adjustment.\u003c\/p\u003e\n\u003ch2\u003eDoes the unit use constant current?\u003c\/h2\u003e\n\u003cp\u003eIt is a controller-based direct-current iontophoresis device. It attempts to maintain the selected current but may operate below that setting when skin or circuit resistance prevents the requested level while adjusting treatment time to deliver the selected dose when possible.\u003c\/p\u003e\n\u003ch2\u003eWhat batteries does it use?\u003c\/h2\u003e\n\u003cp\u003eIt operates on one standard 9V alkaline battery. Rechargeable batteries should not be used. The current package is described as including two 9V batteries.\u003c\/p\u003e\n\u003ch2\u003eAre electrodes included?\u003c\/h2\u003e\n\u003cp\u003eNo disposable iontophoresis electrode kits are included with the standard controller package. Compatible active and return electrodes must be ordered separately.\u003c\/p\u003e\n\u003ch2\u003eIs medication included?\u003c\/h2\u003e\n\u003cp\u003eNo. Medication or solution must be separately prescribed, supplied, and prepared according to applicable professional requirements.\u003c\/p\u003e\n\u003ch2\u003eWhich Balego electrodes are designed for ActivaDose II?\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion Iontophoresis Delivery Kits\u003c\/a\u003e are specifically described as designed for use with ActivaDose II. Other controller-based electrode kits may be appropriate when their labeling and connectors permit use. \u003c\/p\u003e\n\u003ch2\u003eCan the same electrodes be reused?\u003c\/h2\u003e\n\u003cp\u003eNo. The manual specifically prohibits reusing single-use drug and dispersive electrodes.\u003c\/p\u003e\n\u003ch2\u003eWhat does \"electrode reject\" mean?\u003c\/h2\u003e\n\u003cp\u003eIt means the controller has detected an interrupted or unsuitable circuit. Causes may include loose connections, electrode lift, dry skin, insufficient medication, improper hydration, or an unsuitable medication\/setup. Current stops automatically.\u003c\/p\u003e\n\u003ch2\u003eCan treatment be paused?\u003c\/h2\u003e\n\u003cp\u003eYes. The delivered dose is retained, and the unit recalculates remaining time when treatment restarts.\u003c\/p\u003e\n\u003ch2\u003eIs ActivaDose II the same as IontoPATCH?\u003c\/h2\u003e\n\u003cp\u003eNo. ActivaDose II is a reusable external controller used with separate wired electrodes. \u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH\u003c\/a\u003e is a disposable, self-contained wearable system with no external controller or wires.\u003c\/p\u003e\n\u003ch2\u003eCan ActivaDose II be used for TENS or NMES?\u003c\/h2\u003e\n\u003cp\u003eNo. It is an iontophoresis medication-delivery controller. TENS and NMES devices use different output characteristics and are intended for different clinical purposes.\u003c\/p\u003e\n\u003ch2\u003eIs it a direct replacement for the Phoresor II?\u003c\/h2\u003e\n\u003cp\u003eIt is a reasonable current option for clinics replacing a legacy controller-based Phoresor II workflow, but compatibility with existing leads, electrodes, and procedures must be verified rather than assumed.\u003c\/p\u003e\n\u003ch2\u003eWhat is the warranty?\u003c\/h2\u003e\n\u003cp\u003eThe manual specifies a one-year warranty on the controller. Batteries, electrodes, cables, and other accessories are excluded from that warranty.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/device-user-manual-setup-safety-and-specs\/activadose%C2%AE-ii-iontophoresis-delivery-unit-product-manual\"\u003eActivaDose II Product Manual and Setup Guide\u003c\/a\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/iontophoresis\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\"\u003eIontophoresis FAQ Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-evaluation-and-treatment\/iontophoresis-protocol-tennis-elbow-lateral-humeral-epicondylitis\"\u003eIontophoresis Protocol for Tennis Elbow\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"North Coast Medical","offers":[{"title":"Default Title","offer_id":47114743939327,"sku":"NC89186","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/ActivaDose_II_professional_iontophoresis_dose_controller.jpg?v=1784764792","url":"https:\/\/balego-stores.myshopify.com\/products\/activadose-ii-dose-controller-system","provider":"Balego","version":"1.0","type":"link"}