{"product_id":"chemobloc-vial-venting-syringe-system","title":"ChemoBloc \/ ChemoPlus Vial Venting Pin \u0026 Luer-Lock Syringe Kit","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_949fbdbe33c7219d\" dir=\"ltr\"\u003e\n\u003ch2\u003eCardinal Health ChemoPlus™ Vial Venting Pin and Luer-Lock Syringe Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/products\/chemobloc-vial-venting-syringe-system\"\u003eChemoBloc \/ ChemoPlus Vial Venting and Syringe Kit\u003c\/a\u003e includes one Cardinal Health DP5201V filtered vial-access pin and one needle-free Luer-lock syringe for clinician-directed medication preparation.\u003c\/p\u003e\n\u003cp\u003eThe vial-venting pin pierces a compatible medication-vial stopper and provides a secure Luer-lock connection for the syringe. Its built-in 0.22-micron hydrophobic filter helps control vial pressure and reduce aerosolized medication release during withdrawal or reconstitution.\u003c\/p\u003e\n\u003cp\u003eFor iontophoresis workflows, the kit may help a trained healthcare professional withdraw the prescribed volume of compatible medication or solution from a vial and transfer it into the reservoir of an \u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH®\u003c\/a\u003e, \u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch®,\u003c\/a\u003e or another compatible drug-delivery system.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional-use notice:\u003c\/strong\u003e Medication selection, concentration, volume, polarity, dosing and patch compatibility must be determined by the prescriber and handled according to medication labeling, facility policy and the instructions supplied with every component.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eMedication and iontophoresis patches are sold separately.\u003c\/p\u003e\n\u003cp\u003eDP5201V is a sterile, single-use, needleless vial-venting product with a Luer-lock connection and a nonpyrogenic fluid path. \u003c\/p\u003e\n\u003ch2\u003eProduct highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne Cardinal Health DP5201V vial-venting pin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne needle-free Luer-lock syringe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFiltered vial access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0.22-micron hydrophobic air filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeedleless syringe connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure Luer-lock interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned to help reduce aerosol release during vial access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSterile, nonpyrogenic fluid path in the vial-venting component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilitates withdrawal and transfer of liquid medication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-use components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVial-venting pin not made with natural rubber latex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUseful for professional medication-preparation workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMay be used when filling compatible iontophoresis reservoirs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedication not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIontophoresis patch not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot intended for direct patient injection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot automatically equivalent to a closed-system drug-transfer device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFiltered, needleless vial access and rapid solution transfer.\u003c\/p\u003e\n\u003ch1\u003eQuick specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eProduct detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct name\u003c\/td\u003e\n\u003ctd\u003eVial venting pin and Luer-lock syringe kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial-vent brand\u003c\/td\u003e\n\u003ctd\u003eCardinal Health ChemoPlus™; formerly marketed as ChemoBloc™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial-vent model\u003c\/td\u003e\n\u003ctd\u003eDP5201V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter\u003c\/td\u003e\n\u003ctd\u003e0.22-micron hydrophobic filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial connection\u003c\/td\u003e\n\u003ctd\u003ePiercing cannula\/spike\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe connection\u003c\/td\u003e\n\u003ctd\u003eLuer lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle required\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid path\u003c\/td\u003e\n\u003ctd\u003eThe vial vent is sterile and nonpyrogenic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural rubber latex\u003c\/td\u003e\n\u003ctd\u003eThe vial vent is not made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReuse\u003c\/td\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial vents included\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringes included\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe size\u003c\/td\u003e\n\u003ctd\u003eVerify before publishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatch included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary original application\u003c\/td\u003e\n\u003ctd\u003eReconstitution and withdrawal of chemotherapy and other hazardous drugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego positioning\u003c\/td\u003e\n\u003ctd\u003eProfessional medication transfer and iontophoresis patch preparation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect injection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSTD classification\u003c\/td\u003e\n\u003ctd\u003eNot established by the sources reviewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eImportant iontophoresis fill-volume correction\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIontophoresis product\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePublished reservoir volume\u003c\/th\u003e\n\u003cth\u003eBalego link\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIontoPATCH STAT\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.0 mL\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH products\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIontoPATCH 80\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.3 mL\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH products\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIontoPATCH Extra Strength\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.0 mL\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH products\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACTIVApatch IontoGo 4.0\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch products\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACTIVApatch IontoGo 12.0\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch products\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompanion 80\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.1 cc\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/5000044\"\u003eCompanion 80\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhat the filtered vial vent does\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent feature\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiercing cannula\u003c\/td\u003e\n\u003ctd\u003eAccesses the vial through its stopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrophobic filter\u003c\/td\u003e\n\u003ctd\u003eAllows pressure equalization while helping filter aerosolized droplets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuer-lock port\u003c\/td\u003e\n\u003ctd\u003eProvides a threaded connection for a compatible syringe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedleless design\u003c\/td\u003e\n\u003ctd\u003eAvoids the use of a conventional sharp needle for withdrawal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile fluid path\u003c\/td\u003e\n\u003ctd\u003eSupports preparation when packaging and handling remain intact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective covers\u003c\/td\u003e\n\u003ctd\u003eProtect the spike and connection before use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe filter and needleless design may reduce certain exposure risks, but they do not eliminate the need for proper technique, personal protective equipment, engineering controls, or facility procedures. \u003c\/p\u003e\n\u003ch1\u003eIs this a closed-system transfer device?\u003c\/h1\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThe DP5201V is a filtered vial-venting device designed to help reduce aerosolization during medication withdrawal. It should not be represented as a complete closed-system drug-transfer device unless the facility has documentation establishing that classification and intended use.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch1\u003eProduct comparison\u003c\/h1\u003e\n\u003ch2\u003eVial venting kit vs. other medication-withdrawal options\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eChemoPlus\/ChemoBloc vent + syringe\u003c\/th\u003e\n\u003cth\u003eStandard needle and syringe\u003c\/th\u003e\n\u003cth\u003eBlunt-fill needle\u003c\/th\u003e\n\u003cth\u003eNeedleless vial-access cannula\u003c\/th\u003e\n\u003cth\u003eFDA-classified CSTD\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharp metal needle\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltered pressure vent\u003c\/td\u003e\n\u003ctd\u003eYes, 0.22 micron\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUsually not.\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLuer-lock syringe connection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003eCommon\u003c\/td\u003e\n\u003ctd\u003eProprietary or Luer-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelps manage vial pressure\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eManual air exchange\u003c\/td\u003e\n\u003ctd\u003eManual air exchange\u003c\/td\u003e\n\u003ctd\u003eDevice-dependent\u003c\/td\u003e\n\u003ctd\u003eYes, by system design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesigned to help reduce aerosolization\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo specific feature\u003c\/td\u003e\n\u003ctd\u003eNo specific feature\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrevents needlestick from fill needle\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eReduced but not eliminated\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSTD classification\u003c\/td\u003e\n\u003ctd\u003eNot established\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eFiltered, needleless vial access\u003c\/td\u003e\n\u003ctd\u003eGeneral medication withdrawal when permitted\u003c\/td\u003e\n\u003ctd\u003eSafer alternative to conventional sharp-fill needle\u003c\/td\u003e\n\u003ctd\u003eRoutine needleless vial access\u003c\/td\u003e\n\u003ctd\u003eHazardous-drug workflows requiring a verified CSTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative complexity\u003c\/td\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003eLow\u003c\/td\u003e\n\u003ctd\u003eHigher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eIontophoresis medication-transfer workflow\u003c\/h1\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/collections\/iontophoresis\"\u003eBalego Iontophoresis collection\u003c\/a\u003e notes that medication selection, polarity, dose, and treatment instructions remain the responsibility of the prescribing clinician. \u003c\/p\u003e\n\u003ch1\u003eWhat is included?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded component\u003c\/th\u003e\n\u003cth align=\"right\"\u003eQuantity\u003c\/th\u003e\n\u003cth\u003eImportant note\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardinal Health DP5201V vial-venting pin\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle-free Luer-lock syringe\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eAdd exact capacity and product number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0\u003c\/td\u003e\n\u003ctd\u003eObtained separately under appropriate order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/shop?page=1\u0026amp;amp;searchTerm=Iontophoresis+patch\"\u003eIontophoresis patch\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0\u003c\/td\u003e\n\u003ctd\u003ePurchased separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/sterile-alcohol-prep\"\u003eAlcohol prep\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0\u003c\/td\u003e\n\u003ctd\u003eNot currently listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.balego.com\/collections\/medical-gloves\"\u003eGloves \u003c\/a\u003eor PPE\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0\u003c\/td\u003e\n\u003ctd\u003eSelected according to medication and facility policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.balego.com\/collections\/sharps-containers\"\u003eSharps\u003c\/a\u003e or hazardous-waste container\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0\u003c\/td\u003e\n\u003ctd\u003eDisposal depends on the preparation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eSafety and handling\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety issue\u003c\/th\u003e\n\u003cth\u003eRecommended guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamaged packaging\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreviously opened component\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReuse\u003c\/td\u003e\n\u003ctd\u003eDo not reuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe or vent contamination\u003c\/td\u003e\n\u003ctd\u003eDiscard immediately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouching the Luer or spike\u003c\/td\u003e\n\u003ctd\u003eAvoid contact with critical surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication compatibility\u003c\/td\u003e\n\u003ctd\u003eVerify before use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatch fill volume\u003c\/td\u003e\n\u003ctd\u003eFollow the exact patch instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous drugs\u003c\/td\u003e\n\u003ctd\u003eFollow USP \u003ccode\u003e\u0026lt;800\u0026gt;\u003c\/code\u003e, NIOSH, and facility controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSTD requirement\u003c\/td\u003e\n\u003ctd\u003eUse a verified CSTD whenever required by policy or regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect injection\u003c\/td\u003e\n\u003ctd\u003eThis Balego kit is positioned for transfer, not patient injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eFollow medication-specific and facility waste requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHome use\u003c\/td\u003e\n\u003ctd\u003eNot appropriate for unsupervised medication preparation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the ChemoBloc vial venting system?\u003c\/h2\u003e\n\u003cp\u003eIt is a filtered, needleless vial-access device currently marketed by Cardinal Health as the ChemoPlus vial venting system. The manufacturer number is DP5201V.\u003c\/p\u003e\n\u003ch2\u003eWhat does the kit include?\u003c\/h2\u003e\n\u003cp\u003eThe listing includes one DP5201V vial-venting pin and one needle-free Luer-lock syringe.\u003c\/p\u003e\n\u003ch2\u003eDoes the kit include medication?\u003c\/h2\u003e\n\u003cp\u003eNo.\u003c\/p\u003e\n\u003ch2\u003eDoes it include an iontophoresis patch?\u003c\/h2\u003e\n\u003cp\u003eNo. Compare \u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH\u003c\/a\u003e and \u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch\u003c\/a\u003e products separately.\u003c\/p\u003e\n\u003ch2\u003eIs the vial vent sterile?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health describes the DP5201V fluid path as sterile and nonpyrogenic. The bundle should not be described as one sterile kit unless both components remain individually packaged and the claim is supported. \u003c\/p\u003e\n\u003ch2\u003eIs it reusable?\u003c\/h2\u003e\n\u003cp\u003eNo. DP5201V is a single-use product.\u003c\/p\u003e\n\u003ch2\u003eIs it latex-free?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health states that the vial-venting product is not made with natural rubber latex. Verify the syringe separately.\u003c\/p\u003e\n\u003ch2\u003eIs it a closed-system transfer device?\u003c\/h2\u003e\n\u003cp\u003eThe sources reviewed identify it as a filtered vial-venting system, not as an FDA ONB-classified CSTD. Do not use the terms interchangeably.\u003c\/p\u003e\n\u003ch2\u003eDoes the filter sterilize medication?\u003c\/h2\u003e\n\u003cp\u003eNo. The hydrophobic vent filter is part of the air-pressure management system. It does not sterilize the medication or correct contamination caused by improper technique.\u003c\/p\u003e\n\u003ch2\u003eDoes the system guarantee that medication cannot spill or aerosolize?\u003c\/h2\u003e\n\u003cp\u003eNo. Cardinal Health says it is designed to help prevent aerosolization. Proper technique and facility controls remain necessary.\u003c\/p\u003e\n\u003ch2\u003eHow much medication should be withdrawn?\u003c\/h2\u003e\n\u003cp\u003eWithdraw the exact amount prescribed by the clinician and specified in the patch instructions. Do not use 1.0 mL as a universal rule.\u003c\/p\u003e\n\u003ch2\u003eCan it be used with IontoPATCH 80?\u003c\/h2\u003e\n\u003cp\u003eYes, when the medication, vial, syringe, and facility protocol are compatible. \u003c\/p\u003e\n\u003ch2\u003eCan it be used with IontoGo?\u003c\/h2\u003e\n\u003cp\u003eYes. Specifications list a 2.0 cc reservoir for IontoGo 4.0 and IontoGo 12.0. \u003c\/p\u003e\n\u003ch2\u003eCan patients use this kit to prepare medication at home?\u003c\/h2\u003e\n\u003cp\u003ePrescription medication selection and transfer should follow prescriber, pharmacy, and facility directions.\u003c\/p\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/iontophoresis\"\u003eIontophoresis Patches, Electrodes and Dose Controllers\u003c\/a\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iogel-iontophoresis-electrodes\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\"\u003eIontophoresis Electrode Directions\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e\n\u003c\/div\u003e","brand":"Balego","offers":[{"title":"Default Title","offer_id":47299515777279,"sku":"DP5201V","price":6.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Cardinal_Health_DP5201V_ChemoPlus_vial_venting_pin.webp?v=1784914970","url":"https:\/\/balego-stores.myshopify.com\/products\/chemobloc-vial-venting-syringe-system","provider":"Balego","version":"1.0","type":"link"}