{"product_id":"hydrocollator-heating-units","title":"Chattanooga Hydrocollator Heating Units | E-1, SS-2, M-2 \u0026 M-4","description":"\u003ch1\u003eChattanooga Hydrocollator HotPac Heating Units\u003c\/h1\u003e\n\u003cp\u003eChattanooga® Hydrocollator® Heating Units are a centralized hot-water system that stores and heats reusable \u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-moist-heat-hot-pac\" target=\"_blank\" rel=\"noopener\"\u003eHydrocollator Moist Heat HotPacs\u003c\/a\u003e for physical therapy, rehabilitation, sports medicine, and other professional treatment environments.\u003c\/p\u003e\n\u003cp\u003eChoose from four Balego configurations ranging from the compact \u003cstrong\u003eE-1 stationary unit with four Standard HotPacs\u003c\/strong\u003e to the high-capacity \u003cstrong\u003eM-4 mobile unit with 24 Standard HotPacs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAll four models use stainless-steel tanks, thermostatically controlled water heating, and 110–120 V electrical power. Chattanooga’s current U.S. specifications list a normal HotPac water-temperature range of \u003cstrong\u003e160–165°F (71–74°C)\u003c\/strong\u003e. \u003c\/p\u003e\n\u003ch2\u003eWhich Hydrocollator model should I choose?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth align=\"right\"\u003eIncluded HotPacs\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCurrent tank capacity\u003c\/th\u003e\n\u003cth\u003eFootprint\u003c\/th\u003e\n\u003cth\u003eBest general fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE-1 — 2102\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStationary\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4 Standard\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3 gal \/ 11 L\u003c\/td\u003e\n\u003ctd\u003e13\" × 8\" × 16\"\u003c\/td\u003e\n\u003ctd\u003eIndividual treatment room, small clinic or low-volume heat station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSS-2 — 2302\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMobile\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e8 Standard\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 gal \/ 37 L\u003c\/td\u003e\n\u003ctd\u003e21\" × 16\" × 33\"\u003c\/td\u003e\n\u003ctd\u003eClinic needing mobility without the footprint of an M-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM-2 — 2402\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMobile\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 Standard\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e14 gal \/ 52 L*\u003c\/td\u003e\n\u003ctd\u003e27\" × 16\" × 33\"\u003c\/td\u003e\n\u003ctd\u003eModerate-to-high treatment volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM-4 — 2502\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMobile\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e24 Standard\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e27 gal \/ 102 L\u003c\/td\u003e\n\u003ctd\u003e35\" × 20\" × 33\"\u003c\/td\u003e\n\u003ctd\u003eLarge rehab department or high-throughput facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFast selection guide\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eYour priority\u003c\/th\u003e\n\u003cth\u003eModel to consider\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest footprint\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eE-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountertop \/ stationary setup\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eE-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest mobile Hydrocollator\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSS-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMore HotPacs without moving to the largest tank\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eM-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHighest included HotPac count\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eM-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEight-pack mobile workflow\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSS-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwelve-pack mobile workflow\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eM-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge multi-room department\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eM-4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eComplete model comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"right\"\u003eE-1\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSS-2\u003c\/th\u003e\n\u003cth align=\"right\"\u003eM-2\u003c\/th\u003e\n\u003cth align=\"right\"\u003eM-4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2102\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2302\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2402\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStyle\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eStationary\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMobile\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMobile\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMobile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard HotPacs included\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e8\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e110–120 V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e110–120 V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e110–120 V\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e110–120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1000 W\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1000 W\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1000 W\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater temperature\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160–165°F\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160–165°F\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160–165°F\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160–165°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank capacity, current U.S. listing\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3 gal\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 gal\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e14 gal*\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e27 gal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat-up to 160°F\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 2 hr\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 4 hr\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 8 hr*\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 8 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct dimensions\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e13\" L × 8\" W × 16\" H\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e21\" L × 16\" W × 33\" H\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e27\" L × 16\" W × 33\" H\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e35\" L × 20\" W × 33\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasters\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermanent plumbing required\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStainless-steel construction\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eE-1: compact stationary Hydrocollator\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eE-1\u003c\/strong\u003e is the smallest option in this product family. It measures approximately 13 × 8 × 16 inches and comes with four standard HotPacs.\u003c\/p\u003e\n\u003cp\u003eIt is best suited for a treatment room or smaller practice where:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFour Standard HotPacs provide enough ready inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFloor space is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA mobile tank is unnecessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStaff can place the unit on an appropriate stable surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants the lowest-capacity entry into the professional Hydrocollator line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe E-1 is stationary, so its placement deserves more consideration than simply finding available counter space. The manufacturer requires a smooth, level surface capable of supporting the \u003cstrong\u003efilled weight\u003c\/strong\u003e, not merely the dry unit.\u003c\/p\u003e\n\u003ch2\u003eSS-2: compact mobile model\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSS-2\u003c\/strong\u003e adds a floor-standing mobile chassis and eight included standard HotPacs while remaining considerably smaller than the M-4. It has an approximate operating capacity of 10 gallons and a footprint of 21 × 16 × 33 inches. \u003c\/p\u003e\n\u003cp\u003eChoose the SS-2 when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEight ready Standard HotPacs fit better than four HotPacs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountertop space is unavailable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA floor-standing unit is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants casters for positioning an \u003cstrong\u003eempty or safely prepared unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eM-2 or M-4 capacity would be unnecessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe mobile chassis should not be confused with permission to wheel around a tank full of 160°F water. Chattanooga specifically warns not to move a Hydrocollator while it is filled with heated water because tipping creates a burn hazard.\u003c\/p\u003e\n\u003ch2\u003eM-2: mid-capacity clinic workhorse\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eM-2\u003c\/strong\u003e is the middle choice for facilities that routinely use more HotPacs but do not require the footprint or 24-pack inventory of the M-4. Includes 12 Standard HotPacs and has dimensions of 27 × 16 × 33 inches. \u003c\/p\u003e\n\u003cp\u003eThe M-2 generally makes the most sense when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSeveral treatment tables share one heat station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwelve included Standard HotPacs better match the daily turnover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMobile floor placement is preferable to a stationary tank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe SS-2 would require excessive pack cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe M-4 would consume more floor space than the clinic needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eM-4: highest-capacity Balego option\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eM-4\u003c\/strong\u003e is the largest Hydrocollator in this four-model selector. 27-gallon approximate operating capacity, 35 × 20 × 33-inch dimensions, and 24 included standard hot packs. \u003c\/p\u003e\n\u003cp\u003eIt is designed for facilities where the limiting factor is less likely to be tank size and more likely to be the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of concurrent treatment rooms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePack turnover throughout the day\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable floor space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFilled equipment weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStartup planning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy model capacity matters more than the thermostat\u003c\/h2\u003e\n\u003cp\u003eAll four models are intended to keep compatible HotPacs in the same general temperature range. Buying a larger Hydrocollator does not mean receiving “hotter” therapy; it primarily means gaining \u003cstrong\u003emore tank volume and HotPac capacity\u003c\/strong\u003e. \u003c\/p\u003e\n\u003cp\u003eThat means clinic selection can be approached as a throughput problem:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinic characteristic\u003c\/th\u003e\n\u003cth\u003eMore likely choice\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne treatment room with occasional moist heat\u003c\/td\u003e\n\u003ctd\u003eE-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall multi-table clinic\u003c\/td\u003e\n\u003ctd\u003eSS-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegular moist heat use across several tables\u003c\/td\u003e\n\u003ctd\u003eM-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge PT department or athletic training facility\u003c\/td\u003e\n\u003ctd\u003eM-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimited floor space\u003c\/td\u003e\n\u003ctd\u003eE-1 or SS-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequent simultaneous HotPac demand\u003c\/td\u003e\n\u003ctd\u003eM-2 or M-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeed for oversize\/specialty HotPacs in addition to standard inventory\u003c\/td\u003e\n\u003ctd\u003eConsider larger tank capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eActual capacity for mixed HotPac shapes will vary because a standard, neck contour, spinal, and oversize pack occupy different amounts of tank space. We offer those shapes separately on the \u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-moist-heat-hot-pac\"\u003eHydrocollator Moist Heat HotPac page\u003c\/a\u003e. The HotPac line currently includes multiple anatomical shapes and sizes. \u003c\/p\u003e\n\u003ch2\u003eWhat comes with each model?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHeating unit\u003c\/th\u003e\n\u003cth align=\"right\"\u003eIncluded Standard HotPacs\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-1\u003c\/td\u003e\n\u003ctd\u003eChattanooga Hydrocollator 2102\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSS-2\u003c\/td\u003e\n\u003ctd\u003eChattanooga Hydrocollator 2302\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM-2\u003c\/td\u003e\n\u003ctd\u003eChattanooga Hydrocollator 2402\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM-4\u003c\/td\u003e\n\u003ctd\u003eChattanooga Hydrocollator 2502\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe included packs let a clinic start with a baseline standard HotPac inventory. Additional sizes—including Half Size, Spinal, Knee\/Shoulder, Neck Contour, and Oversize—can be ordered from our \u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-moist-heat-hot-pac\"\u003eHydrocollator HotPac selection\u003c\/a\u003e. \u003c\/p\u003e\n\u003ch2\u003eHotPacs and covers are separate parts of the system\u003c\/h2\u003e\n\u003cp\u003eA Hydrocollator unit heats and stores the packs; it is not itself the patient-contact treatment surface.\u003c\/p\u003e\n\u003cp\u003eA complete clinical workflow usually involves:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydrocollator heating unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintains HotPacs in heated water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-moist-heat-hot-pac\"\u003eHydrocollator Moist Heat HotPac\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eReusable heat-retaining treatment pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-all-terry-covers\"\u003eHydrocollator All-Terry Cover\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides insulating layers between heated HotPac and the patient.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTowels \/ facility linens as directed\u003c\/td\u003e\n\u003ctd\u003eAdditional insulation where required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermometer \/ unit controls\u003c\/td\u003e\n\u003ctd\u003eVerifies proper tank operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo \u003cstrong\u003enot apply a Hydrocollator HotPac directly to the skin,\u003c\/strong\u003e and continually monitor the skin during use.\u003c\/p\u003e\n\u003cp\u003eThat safety information is more useful here than duplicating a full moist-heat protocol already covered by associated HotPac literature.\u003c\/p\u003e\n\u003ch2\u003eHydrocollator versus microwave-heated reusable packs\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eHydrocollator + HotPacs\u003c\/th\u003e\n\u003cth\u003eMicrowave-style reusable pack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating method\u003c\/td\u003e\n\u003ctd\u003eContinuously heated water bath\u003c\/td\u003e\n\u003ctd\u003eIndividually reheated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReady inventory\u003c\/td\u003e\n\u003ctd\u003eMultiple packs remain available\u003c\/td\u003e\n\u003ctd\u003eEach pack requires separate heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest environment\u003c\/td\u003e\n\u003ctd\u003eProfessional recurring use\u003c\/td\u003e\n\u003ctd\u003eLower-volume or individual use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup time\u003c\/td\u003e\n\u003ctd\u003eThe unit must reach operating temperature\u003c\/td\u003e\n\u003ctd\u003eUsually shorter per individual pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily water maintenance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank cleaning\u003c\/td\u003e\n\u003ctd\u003eRequired\u003c\/td\u003e\n\u003ctd\u003eNo tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-room throughput\u003c\/td\u003e\n\u003ctd\u003eStrong advantage\u003c\/td\u003e\n\u003ctd\u003eMore manual reheating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment footprint\u003c\/td\u003e\n\u003ctd\u003eLarger\u003c\/td\u003e\n\u003ctd\u003eMinimal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack temperature consistency\u003c\/td\u003e\n\u003ctd\u003eControlled by thermostatic water bath\u003c\/td\u003e\n\u003ctd\u003eIt depends on reheating method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary purchasing reason\u003c\/td\u003e\n\u003ctd\u003eWorkflow and repeat availability\u003c\/td\u003e\n\u003ctd\u003eSimplicity and low infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor clinics needing only occasional hot\/cold applications rather than a continuously maintained HotPac inventory, we also carry \u003ca href=\"https:\/\/www.balego.com\/products\/reusable-hot-cold-gel-packs\"\u003ereusable hot and cold gel packs\u003c\/a\u003e. These products solve a different workflow problem and should not be represented as identical to the Hydrocollator system.\u003c\/p\u003e\n\u003ch2\u003eStationary versus mobile Hydrocollator units\u003c\/h2\u003e\n\u003cp\u003eThe word \u003cstrong\u003e\"mobile\"\u003c\/strong\u003e refers to the castered chassis on the SS-2, M-2, and M-4. It does not mean the unit should be transported around a clinic while filled with hot water.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eE-1\u003c\/th\u003e\n\u003cth\u003eSS-2 \/ M-2 \/ M-4\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eStationary\u003c\/td\u003e\n\u003ctd\u003eFloor-standing mobile chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasters\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical placement\u003c\/td\u003e\n\u003ctd\u003eStable counter or dedicated support\u003c\/td\u003e\n\u003ctd\u003eFloor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEasier to reposition when safely emptied\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafe to roll while full of hot water\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor-space requirement\u003c\/td\u003e\n\u003ctd\u003eLowest\u003c\/td\u003e\n\u003ctd\u003eIncreases by model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eElectrical and installation planning\u003c\/h2\u003e\n\u003cp\u003eThe current U.S. models are rated at \u003cstrong\u003e110–120 V and 1000 W\u003c\/strong\u003e. They do not require a permanent water line, but they do require routine manual filling because evaporation lowers the water level during operation. \u003c\/p\u003e\n\u003cp\u003eBefore choosing the installation location, confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA properly grounded electrical outlet is available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe surface or floor is level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe installation area can tolerate incidental water exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe selected location can support the filled weight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStaff can access the tank safely for filling and drainage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe drain location and cleaning workflow are practical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMobile units have enough surrounding clearance to service and clean them.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer manual calls for a grounded outlet, level support, and adequate load capacity for the filled unit.\u003c\/p\u003e\n\u003ch2\u003eDaily water level matters\u003c\/h2\u003e\n\u003cp\u003eA Hydrocollator continuously loses water through evaporation. Chattanooga instructs users to monitor and replenish the water \u003cstrong\u003edaily\u003c\/strong\u003e and to keep the HotPacs fully submerged. Allowing the water level to fall below the packs can damage both the packs and the equipment.\u003c\/p\u003e\n\u003cp\u003eA useful opening checklist is the following:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the tank and electrical cord.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the water covers the HotPacs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the unit has reached its prescribed operating range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect packs for deterioration or leaking filler.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep unsuitable metal objects and contaminants away from the tank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eChattanooga recommends replacing HotPacs when the fabric or filling begins to deteriorate.\u003c\/p\u003e\n\u003ch2\u003eCleaning and maintenance\u003c\/h2\u003e\n\u003cp\u003eHydrocollator ownership involves more maintenance than simply adding water.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer calls for the tank to be drained, cleaned, and inspected at least \u003cstrong\u003eevery two weeks\u003c\/strong\u003e, with more frequent cleaning potentially necessary in hard-water conditions. Water should be replenished daily.\u003c\/p\u003e\n\u003ch3\u003eManufacturer maintenance essentials\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMaintenance item\u003c\/th\u003e\n\u003cth\u003eManufacturer guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck\/add water\u003c\/td\u003e\n\u003ctd\u003eDaily\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeep packs submerged\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrain and clean the tank.\u003c\/td\u003e\n\u003ctd\u003eAt least every 2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard-water areas\u003c\/td\u003e\n\u003ctd\u003eMay require more frequent cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBleach\/high-chlorine cleaners\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon-steel wool\/brush\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForeign additives or essential oils\u003c\/td\u003e\n\u003ctd\u003eDo not add\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInspect heating element\u003c\/td\u003e\n\u003ctd\u003eDuring regular cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInspect power cord\u003c\/td\u003e\n\u003ctd\u003eDuring regular cleaning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003ctd\u003eNon-abrasive stainless-steel care\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eExcessive chlorine can damage the stainless steel, prohibits bleach\/high-chlorine cleaners, and states that improper maintenance can void the warranty.\u003c\/p\u003e\n\u003ch3\u003eDo not add essential oils or other substances\u003c\/h3\u003e\n\u003cp\u003eThe Hydrocollator is designed to heat \u003cstrong\u003ewater and HotPacs\u003c\/strong\u003e. The manufacturer specifically warns that substances such as essential oils, herbal preparations, and other foreign additives can damage the HotPacs and heating unit and may void warranty coverage.\u003c\/p\u003e\n\u003cp\u003eThat point is worth including because it addresses a real ownership question without repeating generic heat-therapy information found elsewhere on Balego.\u003c\/p\u003e\n\u003ch2\u003eWhat is the warm-up time?\u003c\/h2\u003e\n\u003cp\u003eWarm-up is an equipment-planning specification, not a treatment time.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCurrent manufacturer warm-up specification to 160°F\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-1\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 2 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSS-2\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM-2\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 8 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM-4\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApprox. 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor a clinic that opens at 8:00 a.m., this means a large Hydrocollator should generally be thought of as equipment that is brought to operating condition as part of facility startup—not something switched on immediately before the first patient. Exact operational procedures should follow the current unit manual.\u003c\/p\u003e\n\u003ch2\u003eDoes a bigger Hydrocollator make HotPacs hotter?\u003c\/h2\u003e\n\u003cp\u003eNo. The current four units share the same specified \u003cstrong\u003e160–165°F operating range\u003c\/strong\u003e. The main advantages of a larger model are additional tank capacity and HotPac inventory, not a higher therapeutic temperature.\u003c\/p\u003e\n\u003ch2\u003eProfessional moist heat safety\u003c\/h2\u003e\n\u003cp\u003eHydrocollator water is much hotter than the temperature normally tolerated directly on human skin. Chattanooga notes that the tank operates around 160°F, while scalding can occur at far lower temperatures, and the manufacturer specifically prohibits applying a HotPac directly against the skin.\u003c\/p\u003e\n\u003cp\u003eUse appropriate insulation such as a compatible \u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-all-terry-covers\"\u003eHydrocollator All-Terry Cover\u003c\/a\u003e, follow the current HotPac instructions, and monitor the treatment area.\u003c\/p\u003e\n\u003cp\u003eWarns against HotPac use over insensitive skin, poor circulation, cuts, abrasions, or wounds and instructs clinicians to exercise particular caution with people unable to communicate excessive heat.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is a Hydrocollator?\u003c\/h3\u003e\n\u003cp\u003eHydrocollator® is Chattanooga’s registered name for its thermostatically controlled HotPac heating-unit system. The tanks maintain reusable Hydrocollator HotPacs in heated water for professional moist-heat workflows.\u003c\/p\u003e\n\u003ch3\u003eWhich Hydrocollator is the smallest?\u003c\/h3\u003e\n\u003cp\u003eThe E-1 is the smallest model offered on this Balego page. Chattanooga currently lists dimensions of approximately 13 × 8 × 16 inches and includes four standard HotPacs. \u003c\/p\u003e\n\u003ch3\u003eWhich model holds the most HotPacs?\u003c\/h3\u003e\n\u003cp\u003eThe M-4 package includes 24 Standard HotPacs and is the highest-capacity model.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between SS-2 and M-2?\u003c\/h3\u003e\n\u003cp\u003eBoth are mobile floor units. The SS-2 comes with eight Standard HotPacs, while the M-2 comes with 12 and has a longer footprint and greater listed tank capacity. \u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between M-2 and M-4?\u003c\/h3\u003e\n\u003cp\u003eThe M-4 is substantially larger. It includes 24 Standard HotPacs versus 12 with the M-2 and has approximately twice the currently listed water capacity. \u003c\/p\u003e\n\u003ch3\u003eDo the units require plumbing?\u003c\/h3\u003e\n\u003cp\u003eNo permanent plumbing is required. Water is added manually, and the unit must be periodically drained and cleaned.\u003c\/p\u003e\n\u003ch3\u003eHow hot does a Hydrocollator get?\u003c\/h3\u003e\n\u003cp\u003eThe normal manufacturer-specified operating range is approximately 160–165°F (71–74°C). That temperature refers to the tank water, not a safe direct-to-skin application temperature. \u003c\/p\u003e\n\u003ch3\u003eCan a HotPac be applied directly to the skin?\u003c\/h3\u003e\n\u003cp\u003eNo. Chattanooga specifically states not to apply a Hydrocollator HotPac directly to skin. Use appropriate insulation and follow current application instructions.\u003c\/p\u003e\n\u003ch3\u003eCan I wheel an SS-2, M-2, or M-4 into another room while it is full?\u003c\/h3\u003e\n\u003cp\u003eNot while it contains heated water. The manufacturer warns against moving a filled Hydrocollator because tipping can cause burns.\u003c\/p\u003e\n\u003ch3\u003eHow often should the Hydrocollator be cleaned?\u003c\/h3\u003e\n\u003cp\u003eChattanooga recommends draining and cleaning at least every two weeks, with more frequent cleaning potentially needed in challenging water conditions.\u003c\/p\u003e\n\u003ch3\u003eDoes the water need to be changed daily?\u003c\/h3\u003e\n\u003cp\u003eThe manual specifically requires checking and adding water daily because of evaporation, while the tank itself should be regularly drained and cleaned.\u003c\/p\u003e\n\u003ch3\u003eCan bleach be used to disinfect the tank?\u003c\/h3\u003e\n\u003cp\u003eNo. The manufacturer says not to use bleach or cleaners with high chlorine content because they can damage the stainless steel.\u003c\/p\u003e\n\u003ch3\u003eCan essential oils be added to the water?\u003c\/h3\u003e\n\u003cp\u003eNo. Chattanooga states that substances such as essential oils and herbal preparations can damage the tank and HotPacs and may void the warranty.\u003c\/p\u003e\n\u003ch3\u003eDo all four models operate at the same temperature?\u003c\/h3\u003e\n\u003cp\u003eYes. Chattanooga’s current U.S. specifications list 160–165°F for E-1, SS-2, M-2, and M-4. \u003c\/p\u003e\n\u003ch3\u003eAre HotPacs included?\u003c\/h3\u003e\n\u003cp\u003eYes, our current configurations include four with E-1, eight with SS-2, 12 with M-2, and 24 with M-4. \u003c\/p\u003e\n\u003ch3\u003eCan other HotPac sizes be purchased?\u003c\/h3\u003e\n\u003cp\u003eYes. We offer \u003ca href=\"https:\/\/www.balego.com\/products\/hydrocollator-moist-heat-hot-pac\"\u003eHydrocollator HotPacs\u003c\/a\u003e in standard, half-size, spinal, knee\/shoulder, neck contour, and oversize configurations. \u003c\/p\u003e\n\u003ch3\u003eWhat is the manufacturer warranty?\u003c\/h3\u003e\n\u003cp\u003eThe available Chattanooga Hydrocollator manual documents a one-year warranty against defects in materials and workmanship, subject to its conditions and exclusions. Balego should link or supply the current warranty documentation with the product rather than paraphrasing it as an unconditional guarantee.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional equipment notice:\u003c\/strong\u003e Hydrocollator Heating Units contain water maintained at temperatures capable of causing burns. Install, operate, maintain and service the unit according to the current Chattanooga instructions. Do not apply heated HotPacs directly to skin, do not move a unit while it contains heated water, and monitor patients during moist-heat application.\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Chattanooga Group","offers":[{"title":"E-1 Stationary - Includes (4) Standard HotPacs","offer_id":48973825016063,"sku":"2102","price":729.65,"currency_code":"USD","in_stock":true},{"title":"SS-2 Mobile - Includes (8) Standard HotPacs","offer_id":48973825048831,"sku":"2302","price":2205.31,"currency_code":"USD","in_stock":true},{"title":"M-2 Mobile - Includes (12) Standard HotPacs","offer_id":48973825081599,"sku":"2402","price":2445.8,"currency_code":"USD","in_stock":true},{"title":"M-4 - Mobile Includes (24) Standard HotPacs","offer_id":48973825114367,"sku":"2502","price":4174.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Hydrocollator_Heating_Units_Hi_1.jpg?v=1786119384","url":"https:\/\/balego-stores.myshopify.com\/products\/hydrocollator-heating-units","provider":"Balego","version":"1.0","type":"link"}