{"product_id":"intelect-legend-2-combo","title":"Chattanooga Intelect Legend 2 Combo | 2- or 4-Channel E-Stim + Ultrasound","description":"\u003ch2\u003eChattanooga® Intelect® Legend 2 Combination Therapy System\u003c\/h2\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/products\/intelect-legend-2-combo\"\u003eChattanooga Intelect Legend 2 Combo\u003c\/a\u003e is a professional clinical therapy system that combines electrical stimulation, therapeutic ultrasound, and ultrasound-plus-electrotherapy combination treatment into one modern platform.\u003c\/p\u003e\n\u003cp\u003eChoose a \u003cstrong\u003etwo-channel\u003c\/strong\u003e configuration for standard clinical stimulation and combination-therapy workflows, or a four-channel configuration when the practice needs more electrotherapy outputs for broader, bilateral, or multiple treatment setups.\u003c\/p\u003e\n\u003cp\u003eBoth systems come with 12 electrotherapy waveforms, dual-frequency therapeutic ultrasound, a high-resolution 7-inch color touchscreen, suggested protocol settings, customizable parameters, and space for up to 12 home-screen treatment shortcuts. Chattanooga’s app-like interface is designed to help clinicians move quickly between treatment setup, protocol selection, anatomical education, and real-time treatment monitoring. \u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional-use notice:\u003c\/strong\u003e The Intelect Legend 2 is intended for use only under the prescription and supervision of a licensed medical practitioner. Treatment selection, waveform parameters, ultrasound dosage, electrode placement and patient monitoring must follow the current device manual, clinician training and facility procedures.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eFor compatible sound heads, carts, replacement lead wires, and probe accessories, shop \u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eIntelect Legend 2 Accessories\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eProduct highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo- or four-channel clinical electrotherapy options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTherapeutic ultrasound\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound and electrical-stimulation combination therapy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 electrotherapy waveform choices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChattanooga proprietary VMS waveform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterferential and premodulated stimulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRussian stimulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-volt stimulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicrocurrent and direct-current options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 MHz and 3.3 MHz ultrasound\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard 5 cm² ultrasound applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional 1, 2 and 10 cm² applicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproved ultrasound coupling detection and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution 7-inch color touchscreen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuggested Protocol Settings menu\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2\u0026amp;Go home-screen shortcuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSave as many as 12 preset or custom protocols to the home screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution anatomical library\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCustom waveform and parameter controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time treatment display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnboard memory and software-update capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional rechargeable battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated carrying handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional magnetic therapy cart\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible standard and XL lead-wire kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional high-volt probe kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e12 waveforms, a 7-inch touchscreen, SPS and 2\u0026amp;Go features, an optional battery and cart, dual-frequency ultrasound, and multiple applicator choices.\u003c\/p\u003e\n\u003ch1\u003eQuick specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eIntelect Legend 2 Combo\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChattanooga \/ Enovis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eProfessional electrotherapy, ultrasound and combination-therapy system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel choices\u003c\/td\u003e\n\u003ctd\u003eTwo-channel or four-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-channel SKU\u003c\/td\u003e\n\u003ctd\u003e81-5010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFour-channel SKU\u003c\/td\u003e\n\u003ctd\u003e81-5011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy waveforms\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound frequencies\u003c\/td\u003e\n\u003ctd\u003e1 MHz and 3.3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard ultrasound applicator\u003c\/td\u003e\n\u003ctd\u003e5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional applicators\u003c\/td\u003e\n\u003ctd\u003e1, 2 and 10 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch high-resolution color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHome-screen shortcuts\u003c\/td\u003e\n\u003ctd\u003eUp to 12 preset or custom protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Protocol Settings\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnatomical library\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound coupling monitoring\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination therapy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains input\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz, 1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTherapy cart\u003c\/td\u003e\n\u003ctd\u003eOptional, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU.S. use\u003c\/td\u003e\n\u003ctd\u003eProfessional use under prescription and supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eTwo-channel vs. four-channel Intelect Legend 2\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth align=\"right\"\u003e2-Channel Combo\u003c\/th\u003e\n\u003cth align=\"right\"\u003e4-Channel Combo\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer SKU\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e81-5010\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e81-5011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy channels\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination therapy\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-stim waveforms\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e7-inch touchscreen\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e7-inch touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard sound head\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 cm²\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate weight\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e6.8 lb\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e8.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate size\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e14\" × 13.4\" × 5.9\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e14\" × 13.4\" × 7.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eStandard treatment rooms and clinics where two e-stim channels are sufficient\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eHigher-volume clinics needing additional outputs or larger placement flexibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-wire requirement\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChannels 1 and 2\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChannels 1–4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative cost\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eLower\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eHigher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe primary difference is electrotherapy channel capacity. Both configurations retain the Legend 2 software, waveform library, ultrasound system, and workflow tools. \u003c\/p\u003e\n\u003ch2\u003eChoose the two-channel system when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMost clinic treatments use one or two electrode pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe device will frequently be used for ultrasound or combination therapy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour simultaneous electrotherapy outputs are not routinely required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA lower equipment cost is more important than maximum channel capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic is replacing a conventional two-channel combo system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment-room space and equipment weight are priorities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose the four-channel system when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic regularly uses more than two electrotherapy channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarger, bilateral or multi-region setups are common.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA high-volume rehabilitation department may share the device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe additional channel capacity justifies the higher cost and larger enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour-channel IFC, NMES, or other multi-output workflows are part of the practice.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants to avoid replacing a two-channel unit later as treatment volume grows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eThe 12 electrotherapy waveforms\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveform\u003c\/th\u003e\n\u003cth\u003eGeneral professional workflow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMS\u003c\/td\u003e\n\u003ctd\u003eChattanooga muscle-stimulation waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMS Burst\u003c\/td\u003e\n\u003ctd\u003eBurst-format VMS stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVMS FR\u003c\/td\u003e\n\u003ctd\u003eVMS variation with additional frequency-related controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterferential\u003c\/td\u003e\n\u003ctd\u003eTraditional interferential-current workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePremodulated\u003c\/td\u003e\n\u003ctd\u003eTwo-electrode interferential-style stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAsymmetric Biphasic\u003c\/td\u003e\n\u003ctd\u003eSensory or motor stimulation depending on selected parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSymmetric Biphasic\u003c\/td\u003e\n\u003ctd\u003eBiphasic stimulation with balanced phase geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh voltage\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage pulsed-current workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicrocurrent\u003c\/td\u003e\n\u003ctd\u003eVery-low-current professional protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRussian\u003c\/td\u003e\n\u003ctd\u003eMedium-frequency burst muscle stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHAN\u003c\/td\u003e\n\u003ctd\u003eAlternating-frequency stimulation waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Current\u003c\/td\u003e\n\u003ctd\u003eContinuous direct-current applications permitted by the labeling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis table identifies product capabilities rather than treatment recommendations. A qualified professional must select the waveform, intensity, frequency, pulse duration, duty cycle, polarity, and electrode placement. \u003c\/p\u003e\n\u003ch2\u003eChattanooga VMS waveform\u003c\/h2\u003e\n\u003cp\u003eThe VMS waveform is a muscle-stimulation option designed to support stronger contractions, reduced neural fatigue, and improved comfort compared with traditional Russian stimulation.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eChattanooga’s proprietary VMS waveform is designed to support efficient, comfortable muscle contractions while helping clinicians manage stimulation parameters and fatigue during professionally directed muscle-reeducation programs.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch1\u003eTherapeutic ultrasound\u003c\/h1\u003e\n\u003cp\u003eThe Legend 2 Combo provides \u003cstrong\u003e1 MHz and 3.3 MHz therapeutic ultrasound\u003c\/strong\u003e through compatible pre-calibrated applicators.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eUltrasound feature\u003c\/th\u003e\n\u003cth\u003ePractical value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 MHz frequency\u003c\/td\u003e\n\u003ctd\u003eProfessional ultrasound option generally associated with deeper treatment targets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.3 MHz frequency\u003c\/td\u003e\n\u003ctd\u003eHigher-frequency options are generally selected for more superficial treatment targets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 cm² applicator included\u003c\/td\u003e\n\u003ctd\u003eVersatile standard size for many routine treatment areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 cm² applicator\u003c\/td\u003e\n\u003ctd\u003eOptional choice for small, focused regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 cm² applicator\u003c\/td\u003e\n\u003ctd\u003eOptional small-to-medium sound head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 cm² applicator\u003c\/td\u003e\n\u003ctd\u003eOptional choice for broader treatment regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling detection\u003c\/td\u003e\n\u003ctd\u003eHelps identify inadequate sound-head contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eErgonomic applicator\u003c\/td\u003e\n\u003ctd\u003eDesigned for routine clinician handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination mode\u003c\/td\u003e\n\u003ctd\u003eAllows compatible ultrasound and e-stim workflows within one system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Legend 2 sound heads are specific to the Legend 2 platform. Do not substitute an applicator for the Transport 2 merely because the size and frequency appear similar.\u003c\/p\u003e\n\u003cp\u003eShop compatible options on our \u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eIntelect Legend 2 accessories page\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch1\u003eWhat does “combination therapy” mean?\u003c\/h1\u003e\n\u003cp\u003eThe system can be used in three principal ways:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTreatment format\u003c\/th\u003e\n\u003cth\u003eDevice function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy alone\u003c\/td\u003e\n\u003ctd\u003eElectrical stimulation is delivered through compatible electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound alone\u003c\/td\u003e\n\u003ctd\u003eTherapeutic ultrasound is delivered through the selected applicator and ultrasound coupling gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination therapy\u003c\/td\u003e\n\u003ctd\u003eCompatible electrical stimulation and ultrasound are delivered in a coordinated professional workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eUltrasound and electrotherapy may be used independently or in combination. This capability distinguishes the Legend 2 Combo from an electrotherapy-only console such as the \u003ca href=\"https:\/\/www.balego.com\/products\/richmar-quattro-2-5\"\u003eRichmar Quattro 2.5\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch1\u003eWorkflow features\u003c\/h1\u003e\n\u003ch2\u003e2\u0026amp;Go treatments\u003c\/h2\u003e\n\u003cp\u003eThe clinician can place up to 12 preset or custom treatments directly on the home screen. Chattanooga describes the feature as allowing selected treatments to begin within two button presses.\u003c\/p\u003e\n\u003cp\u003eThis feature is best positioned as a shortcut system—not as a claim that every treatment requires only two actions from power-on to patient connection.\u003c\/p\u003e\n\u003ch2\u003eSuggested Protocol Settings\u003c\/h2\u003e\n\u003cp\u003eThe SPS menu allows the clinician to select an indication and view suggested parameters without manually constructing every setting from the beginning.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eSuggested Protocol Settings provide a structured starting point based on the selected indication. The treating professional remains responsible for reviewing and modifying every parameter based on the patient, prescription, treatment goal and response.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eAnatomical library\u003c\/h2\u003e\n\u003cp\u003eThe high-resolution anatomical library can support patient education and help clinicians explain treatment areas and selected pathologies.\u003c\/p\u003e\n\u003cp\u003eIt should not be described as\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA diagnostic system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA replacement for medical imaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAn automated treatment recommendation engine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProof that a displayed protocol is appropriate for every patient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSoftware updates\u003c\/h2\u003e\n\u003cp\u003eThe system includes onboard memory and software-update capability. Free updates or new functionality should be described only when currently offered by Chattanooga and subject to its update policies. \u003c\/p\u003e\n\u003ch1\u003eStandard package\u003c\/h1\u003e\n\u003cp\u003eCurrent distributor information verifies the following for the \u003cstrong\u003etwo-channel model, SKU 81-5010\u003c\/strong\u003e:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded item\u003c\/th\u003e\n\u003cth\u003eQuantity or description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelect Legend 2 two-channel unit\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNylatex wrap\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 1\/2 stimulation lead-wire kit\u003c\/td\u003e\n\u003ctd\u003e1 kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon electrodes\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDURA-STICK PLUS 5 cm square electrodes\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegend 2 -  5 cm² ultrasound applicator\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB drive\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cord\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003ePackage contents depend on the selected two- or four-channel configuration. Each system includes the Legend 2 console, a standard 5 cm² ultrasound applicator, electrotherapy accessories and power components. Confirm the current manufacturer packing list for exact accessory quantities.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch1\u003eProduct comparison\u003c\/h1\u003e\n\u003ch2\u003eIntelect Legend 2 vs. related Balego clinical systems\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIntelect Legend 2 Combo\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport-2\"\u003eIntelect Transport 2 Combo\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/combocare-professional-e-stim-ultrasound-device\"\u003eRichmar ComboCare\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/richmar-quattro-2-5\"\u003eRichmar Quattro 2.5\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormat\u003c\/td\u003e\n\u003ctd\u003eAdvanced clinical combo console\u003c\/td\u003e\n\u003ctd\u003eCompact portable combo\u003c\/td\u003e\n\u003ctd\u003eCompact clinical combo\u003c\/td\u003e\n\u003ctd\u003eClinical e-stim only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-stim channels\u003c\/td\u003e\n\u003ctd\u003e2 or 4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound + e-stim combo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-stim waveforms\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e5 principal waveform families\u003c\/td\u003e\n\u003ctd\u003e5 waveform families\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound frequencies\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003ctd\u003e1 and 3 MHz\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e7-inch color touchscreen\u003c\/td\u003e\n\u003ctd\u003eColor clinical interface\u003c\/td\u003e\n\u003ctd\u003eGraphical LCD\u003c\/td\u003e\n\u003ctd\u003eGraphical LCD with knobs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHome-screen shortcuts\u003c\/td\u003e\n\u003ctd\u003eUp to 12\u003c\/td\u003e\n\u003ctd\u003eProtocol memory\u003c\/td\u003e\n\u003ctd\u003ePresets and custom memory\u003c\/td\u003e\n\u003ctd\u003ePresets and custom programs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSPS indication menu\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eMore streamlined workflow\u003c\/td\u003e\n\u003ctd\u003eNo equivalent Legend 2 SPS\u003c\/td\u003e\n\u003ctd\u003eNo equivalent Legend 2 SPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnatomical library\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eMore limited\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo internal battery listed\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional cart\u003c\/td\u003e\n\u003ctd\u003eMagnetic Legend 2 cart\u003c\/td\u003e\n\u003ctd\u003eTransport 2 carts.\u003c\/td\u003e\n\u003ctd\u003eGeneric cart use\u003c\/td\u003e\n\u003ctd\u003eGeneric cart use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eClinics wanting the broadest waveform selection and modern touchscreen workflow\u003c\/td\u003e\n\u003ctd\u003eMobile clinics and training rooms prioritizing portability\u003c\/td\u003e\n\u003ctd\u003eClinics seeking strong value in a two-channel combo\u003c\/td\u003e\n\u003ctd\u003eClinics needing four-channel e-stim without ultrasound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Legend 2 provides 12 waveforms, while the Transport 2 Combo provides five core stimulation waveforms. ComboCare offers two-channel stimulation, ultrasound and combination therapy at a lower equipment cost, while Quattro 2.5 is intended for clinics that need four-channel stimulation but not therapeutic ultrasound. \u003c\/p\u003e\n\u003ch2\u003eChoose the Intelect Legend 2 when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYour clinic needs electrotherapy and therapeutic ultrasound in one system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 7-inch touchscreen and modern clinical interface are priorities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwelve electrotherapy waveforms are useful.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuggested protocol settings will improve workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe anatomical library is useful for patient education.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo- and four-channel configurations need to be available within one platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional cart and battery use are valuable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple ultrasound applicator sizes are required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe practice expects to use both routine and specialized waveforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eElectrodes, gel and replacement accessories\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eWhen it is needed\u003c\/th\u003e\n\u003cth\u003eBalego link\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegend 2 ultrasound applicators\u003c\/td\u003e\n\u003ctd\u003eReplace or add another treatment-head size\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eLegend 2 Accessories\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel lead-wire kits\u003c\/td\u003e\n\u003ctd\u003eReplacement or backup stimulation leads\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eLegend 2 Accessories\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic therapy cart\u003c\/td\u003e\n\u003ctd\u003eRoom-to-room movement and storage\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eLegend 2 Accessories\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHV probe kit\u003c\/td\u003e\n\u003ctd\u003eCompatible high-volt probe treatments\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eLegend 2 Accessories\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic electrode supply\u003c\/td\u003e\n\u003ctd\u003eRoutine adhesive-pad replacement\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/dura-stick-plus-tens-electrodes\"\u003eDURA-STICK PLUS Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternative electrodes\u003c\/td\u003e\n\u003ctd\u003eCompare sizes, shapes and backing materials\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound contact medium\u003c\/td\u003e\n\u003ctd\u003eRequired for acoustic coupling\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/ultrasound-therapy-and-deep-oscillation\"\u003eUltrasound Therapy and Contact Media\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not add conductive electrode gel to pre-gelled self-adhering pads unless the electrode instructions expressly permit it. Therapeutic ultrasound requires an appropriate acoustic coupling gel; electrode gels and ultrasound gels should not automatically be treated as interchangeable.\u003c\/p\u003e\n\u003ch1\u003eBasic clinical setup overview\u003c\/h1\u003e\n\u003cp\u003eKeep this concise on the product page and rely on the current manual for operational detail.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the prescription, selected modality, and patient suitability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the system, power components, applicator, lead wires, and electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the required accessories before beginning treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect the two- or four-channel electrotherapy configuration being used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChoose electrotherapy, ultrasound, or combination mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse an SPS protocol, a saved shortcut, or manually selected parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReview and modify all suggested parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrepare the skin or ultrasound treatment area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply appropriately sized electrodes or ultrasound coupling gel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBegin at the prescribed output and monitor the patient throughout treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStop treatment immediately for pain, burning, unexpected contraction, dizziness, poor ultrasound coupling, or another adverse response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the skin and equipment after treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean and store accessories according to the manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch1\u003eProfessional-use and safety notes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety topic\u003c\/th\u003e\n\u003cth\u003ePage guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfessional supervision\u003c\/td\u003e\n\u003ctd\u003eUse only under prescription and licensed supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested protocols\u003c\/td\u003e\n\u003ctd\u003eStarting points only; clinician review is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrodes\u003c\/td\u003e\n\u003ctd\u003eUse compatible sizes, complete contact and intact lead wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound gel\u003c\/td\u003e\n\u003ctd\u003eUse an approved coupling medium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator movement\u003c\/td\u003e\n\u003ctd\u003eFollow the manual for movement, contact and treatment technique\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling detection\u003c\/td\u003e\n\u003ctd\u003eRespond to poor-coupling alerts rather than bypassing them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImplanted devices\u003c\/td\u003e\n\u003ctd\u003eFollow all contraindications and precautions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePregnancy\u003c\/td\u003e\n\u003ctd\u003eFollow all electrotherapy and ultrasound restrictions in the manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThrombosis risk\u003c\/td\u003e\n\u003ctd\u003eUse only according to the labeled indication and medical direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin integrity\u003c\/td\u003e\n\u003ctd\u003eInspect before, during and after stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexplained pain\u003c\/td\u003e\n\u003ctd\u003eDo not use to independently diagnose or treat an undiagnosed condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning\u003c\/td\u003e\n\u003ctd\u003eFollow manufacturer-compatible cleaning and disinfection procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eUse the correct Legend 2 sound heads, leads and power accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the Intelect Legend 2 Combo?\u003c\/h2\u003e\n\u003cp\u003eIt is a professional combination-therapy system providing clinical electrical stimulation, therapeutic ultrasound, and compatible ultrasound-plus-e-stim treatment.\u003c\/p\u003e\n\u003ch2\u003eIs it available with two or four channels?\u003c\/h2\u003e\n\u003cp\u003eYes. The two-channel system is SKU 81-5010, and the four-channel system is SKU 81-5011. \u003c\/p\u003e\n\u003ch2\u003eDo both versions include ultrasound?\u003c\/h2\u003e\n\u003cp\u003eYes. Both configurations provide therapeutic ultrasound and electrotherapy\/ultrasound combination capability.\u003c\/p\u003e\n\u003ch2\u003eHow many electrotherapy waveforms are included?\u003c\/h2\u003e\n\u003cp\u003eTwelve: VMS, VMS Burst, VMS FR, Interferential, Premodulated, Asymmetric Biphasic, Symmetric Biphasic, High Volt, Microcurrent, Russian, HAN, and Direct Current. \u003c\/p\u003e\n\u003ch2\u003eWhat ultrasound frequencies are available?\u003c\/h2\u003e\n\u003cp\u003e1 MHz and 3.3 MHz operation. \u003c\/p\u003e\n\u003ch2\u003eWhich ultrasound applicator is included?\u003c\/h2\u003e\n\u003cp\u003eThe standard package includes a 5 cm² Legend 2 ultrasound applicator. Optional 1, 2, and 10 cm² sound heads are available. \u003c\/p\u003e\n\u003ch2\u003eAre Legend 2 and Transport 2 applicators interchangeable?\u003c\/h2\u003e\n\u003cp\u003eNo. They are separate accessory families. Order a sound head specifically identified for the Legend 2. \u003c\/p\u003e\n\u003ch2\u003eWhat is 2\u0026amp;Go?\u003c\/h2\u003e\n\u003cp\u003eIt is a home-screen shortcut feature that lets the clinician save as many as 12 preset or custom protocols for faster access. Chattanooga describes selected treatments as accessible within two button presses. \u003c\/p\u003e\n\u003ch2\u003eWhat is SPS?\u003c\/h2\u003e\n\u003cp\u003eSuggested Protocol Settings provides a starting setup based on a selected indication. The clinician must still review every parameter and confirm that it is suitable for the patient.\u003c\/p\u003e\n\u003ch2\u003eDoes SPS prescribe or diagnose a condition?\u003c\/h2\u003e\n\u003cp\u003eNo. It is a clinical setup aid, not an autonomous diagnostic or prescribing system.\u003c\/p\u003e\n\u003ch2\u003eWhat does the anatomical library do?\u003c\/h2\u003e\n\u003cp\u003eIt provides visual information that can help clinicians explain anatomy, pathologies, and treatments. It does not replace diagnosis, imaging, or professional judgment.\u003c\/p\u003e\n\u003ch2\u003eCan ultrasound and electrical stimulation be used together?\u003c\/h2\u003e\n\u003cp\u003eYes. The system supports independent electrotherapy, independent ultrasound, and compatible combination treatment.\u003c\/p\u003e\n\u003ch2\u003eIs an optional battery available?\u003c\/h2\u003e\n\u003cp\u003eBattery-powered operation as an available option. The battery is not included in the standard system.\u003c\/p\u003e\n\u003ch2\u003eIs the therapy cart included?\u003c\/h2\u003e\n\u003cp\u003eNo. The magnetic Legend 2 cart is optional and can be purchased through our \u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-accessories\"\u003eLegend 2 Accessories page\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat is the difference between the 2CH and 4CH systems?\u003c\/h2\u003e\n\u003cp\u003eThe four-channel version provides two additional stimulation outputs and has a larger, heavier enclosure. The ultrasound capabilities, waveform library, and principal interface features remain consistent.\u003c\/p\u003e\n\u003ch2\u003eIs it suitable for home use?\u003c\/h2\u003e\n\u003cp\u003eIt is a professional system intended for prescription and licensed supervision, not a home electrotherapy product for general consumers.\u003c\/p\u003e\n\u003ch2\u003eDoes it include TENS and NMES?\u003c\/h2\u003e\n\u003cp\u003eIt includes multiple sensory- and motor-level electrical-stimulation waveforms that support TENS- and NMES-type workflows directed by professionals.\u003c\/p\u003e\n\u003ch2\u003eDoes it include interferential stimulation?\u003c\/h2\u003e\n\u003cp\u003eYes. It includes both traditional interferential and premodulated waveforms.\u003c\/p\u003e\n\u003ch2\u003eDoes it include Russian stimulation?\u003c\/h2\u003e\n\u003cp\u003eYes.\u003c\/p\u003e\n\u003ch2\u003eDoes it include microcurrent?\u003c\/h2\u003e\n\u003cp\u003eYes.\u003c\/p\u003e\n\u003ch2\u003eDoes it include direct current?\u003c\/h2\u003e\n\u003cp\u003eYes. Direct-current applications should be performed only according to the manual, labeling, and appropriate professional protocols.\u003c\/p\u003e\n\u003ch2\u003eWhich model is best for a small clinic?\u003c\/h2\u003e\n\u003cp\u003eThe two-channel model is generally the better value when two outputs are sufficient. The four-channel model is appropriate when the practice regularly needs additional stimulation channels.\u003c\/p\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003ca href=\"https:\/\/www.balego.com\/products\/dura-stick-plus-tens-electrodes\"\u003e\u003c\/a\u003e\n\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/which-modalities-to-use\"\u003eWhich Therapy Modality to Use\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/price-guarantee\"\u003eBalego Best Price Guarantee\u003c\/a\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Chattanooga Group","offers":[{"title":"Two-Channel Combo — SKU 81-5010","offer_id":48658594595071,"sku":"81-5010","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"Four-Channel Combo — SKU 81-5011","offer_id":48658594627839,"sku":"81-5011","price":3900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Chattanooga_Intelect_Legend_2_electrotherapy_and_ultrasound_combo_system.jpg?v=1784912157","url":"https:\/\/balego-stores.myshopify.com\/products\/intelect-legend-2-combo","provider":"Balego","version":"1.0","type":"link"}