{"product_id":"intelect-transport-2","title":"Chattanooga Intelect Transport 2 | Ultrasound \u0026 Combo Therapy Systems","description":"\u003ch2\u003eChattanooga® Intelect® Transport 2 – Ultrasound or Electrotherapy Combo\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eChattanooga Intelect Transport 2\u003c\/strong\u003e family gives rehabilitation professionals a compact platform for therapeutic ultrasound, electrotherapy, or combined stimulation and ultrasound treatment.\u003c\/p\u003e\n\u003cp\u003eChoose the \u003cstrong\u003eIntelect Transport 2 Ultrasound, model 4782\u003c\/strong\u003e, for a dedicated portable ultrasound system, or select the \u003cstrong\u003eIntelect Transport 2 Combo, model 4738\u003c\/strong\u003e, to add two electrotherapy channels, five stimulation waveforms, and combination-therapy capability.\u003c\/p\u003e\n\u003cp\u003eBoth configurations include dual-frequency ultrasound, a high-resolution color LCD, an integrated carrying handle, coupling-detection options, an optional rechargeable lithium-ion battery, and compatibility with the optional magnetic therapy cart. The systems are intended for professional clinical use under the supervision of qualified healthcare personnel. \u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional-use device:\u003c\/strong\u003e The Intelect Transport 2 is intended for use under the prescription and supervision of a licensed practitioner. Treatment selection, parameters, applicator use, electrode placement, and safety procedures should follow the current manufacturer instructions. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003eChoose your Intelect Transport 2 model\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e4782 Ultrasound\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e4738 Combo\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTherapeutic ultrasound\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy channels\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination ultrasound + stimulation\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy waveforms\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eVMS, Interferential, Premodulated, High Volt and Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound frequencies\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulsed ultrasound\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous ultrasound\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard applicator size\u003c\/td\u003e\n\u003ctd\u003e5 cm²\u003c\/td\u003e\n\u003ctd\u003e5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional applicators\u003c\/td\u003e\n\u003ctd\u003e2 and 10 cm²\u003c\/td\u003e\n\u003ctd\u003e2 and 10 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser-protocol storage\u003c\/td\u003e\n\u003ctd\u003eUp to 15 protocols\u003c\/td\u003e\n\u003ctd\u003eUp to 15 protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional magnetic cart\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight\u003c\/td\u003e\n\u003ctd\u003e4.2 lb \/ 1.9 kg\u003c\/td\u003e\n\u003ctd\u003e4.9 lb \/ 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer SKU\u003c\/td\u003e\n\u003ctd\u003e4782\u003c\/td\u003e\n\u003ctd\u003e4738\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eClinics needing dedicated portable ultrasound\u003c\/td\u003e\n\u003ctd\u003eClinics needing ultrasound, electrotherapy and combination therapy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eProduct highlights\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo professional therapy configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortable tabletop design with integrated handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution color LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time treatment information\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-frequency therapeutic ultrasound\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 MHz and 3.3 MHz ultrasound operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulsed and continuous ultrasound\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10%, 20%, 50% and 100% duty-cycle options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard 5 cm² ultrasound applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional 2 cm² and 10 cm² applicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound coupling detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAudible alert and treatment-timer response when coupling is interrupted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 15 user-defined protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional 18V lithium-ion battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic battery charging while connected to mains power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional cart with tool-free magnetic mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-channel electrotherapy on the 4738 Combo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFive electrotherapy waveforms on the Combo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrotherapy-ultrasound combination treatment on the Combo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-year manufacturer device warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for professional physical therapy, rehabilitation, chiropractic and athletic-training environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLightweight and durable, with optional battery-powered operation, an ergonomic handle, a color display, improved coupling detection, and a magnetically mounted cart. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eQuick technical specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth align=\"right\"\u003e4782 Ultrasound\u003c\/th\u003e\n\u003cth align=\"right\"\u003e4738 Combo\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem type\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eTherapeutic ultrasound\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eTwo-channel electrotherapy, ultrasound and combination therapy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e13.6\" L × 9.8\" W × 4.7\" H\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e13.6\" L × 9.8\" W × 4.7\" H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetric dimensions\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e34.6 × 25 × 11.9 cm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e34.6 × 25 × 11.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit weight\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.2 lb \/ 1.9 kg\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.9 lb \/ 2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains input\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100–240 VAC, 50\/60 Hz, 1.0 A\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100–240 VAC, 50\/60 Hz, 1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound frequencies\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound modes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003ePulsed and continuous\u003c\/td\u003e\n\u003ctd align=\"right\"\u003ePulsed and continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycles\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10%, 20%, 50% and 100%\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10%, 20%, 50% and 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard applicator\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 cm²\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional applicators\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 and 10 cm²\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 and 10 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy channels\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNone\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy waveforms\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNone\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eFive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom protocols\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUp to 15\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUp to 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional battery\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e18V, 3350 mAh lithium-ion\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e18V, 3350 mAh lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated battery operation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApproximately 1.5–3 hours depending on treatment\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApproximately 1.5–3 hours depending on treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical safety class\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eClass I, ultrasound Type B\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eClass I, electrotherapy Type BF, ultrasound Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eUltrasound therapy capabilities\u003c\/h1\u003e\n\u003cp\u003eBoth Transport 2 configurations include fully functional therapeutic ultrasound.\u003c\/p\u003e\n\u003ch2\u003eDual-frequency operation\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eGeneral workflow consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommonly selected when the treatment plan calls for ultrasound energy at greater tissue depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3.3 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommonly selected for more superficial treatment regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe treating professional must select the frequency, intensity, duty cycle, applicator size, movement rate, and treatment duration. The product page should not assign a fixed depth or treatment protocol to every patient.\u003c\/p\u003e\n\u003ch2\u003ePulsed and continuous output\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eDuty cycle\u003c\/th\u003e\n\u003cth\u003eOutput pattern\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e10%\u003c\/td\u003e\n\u003ctd\u003eShort ultrasound pulses with longer non-output intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e20%\u003c\/td\u003e\n\u003ctd\u003ePulsed output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e50%\u003c\/td\u003e\n\u003ctd\u003eEqual output and non-output portions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e100%\u003c\/td\u003e\n\u003ctd\u003eContinuous ultrasound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe available duty-cycle options are 10%, 20%, 50%, and continuous operation. \u003c\/p\u003e\n\u003ch2\u003eUltrasound coupling detection\u003c\/h2\u003e\n\u003cp\u003eThe system can monitor whether the applicator maintains suitable coupling with the patient. Depending on the selected setting, interrupted contact can trigger an audible alert and stop or pause treatment-time progression. This helps the clinician recognize when the intended ultrasound delivery has been interrupted. \u003c\/p\u003e\n\u003cp\u003eCoupling detection does not remove the need to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eApply an appropriate ultrasound coupling medium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep the sound head moving as required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor patient comfort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the treatment area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow the applicator and device instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBrowse our \u003ca href=\"https:\/\/www.balego.com\/collections\/conductivity-gels-lotions\"\u003econductive gels, lotions, and contact media\u003c\/a\u003e for ultrasound coupling products.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eChoosing an ultrasound applicator\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplicator\u003c\/th\u003e\n\u003cth\u003eRelative treatment footprint\u003c\/th\u003e\n\u003cth\u003eCommon workflow consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd\u003eMore focused or compact anatomical regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral purpose\u003c\/td\u003e\n\u003ctd\u003eStandard applicator supplied with the system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10 cm²\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge\u003c\/td\u003e\n\u003ctd\u003eBroader treatment regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe applicators operate at both supported ultrasound frequencies and incorporate the system’s coupling-monitoring capabilities. \u003c\/p\u003e\n\u003cp\u003eReplacement and optional applicators are available on our \u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport%C2%AE-2-accessories\"\u003eIntelect Transport 2 Accessories\u003c\/a\u003e page.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eElectrotherapy on the 4738 Combo\u003c\/h1\u003e\n\u003cp\u003eThe Combo model adds two stimulation channels and five electrotherapy waveforms.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWaveform\u003c\/th\u003e\n\u003cth\u003eGeneral clinical role\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVMS™\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChattanooga’s proprietary neuromuscular-stimulation waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterferential\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFour-electrode interferential-current treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePremodulated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-electrode premodulated interferential treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Volt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage pulsed-current treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRussian\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurst-modulated medium-frequency muscle stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eVMS is a proprietary symmetrical biphasic waveform designed to elicit efficient muscle contractions. Manufacturer-cited research compares it with Russian stimulation in relation to contraction force, comfort, and fatigue; those benefits should be attributed to Chattanooga rather than presented as guaranteed outcomes for every patient. \u003c\/p\u003e\n\u003ch2\u003eWhy two channels matter\u003c\/h2\u003e\n\u003cp\u003eTwo electrotherapy channels allow the clinician to\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eUse a standard four-electrode interferential setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply two electrode pairs over one treatment region\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreat two compatible regions during a session\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure paired or bilateral muscle-stimulation arrangements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse electrotherapy with therapeutic ultrasound in a combination treatment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe appropriate setup depends on the waveform, clinical indication, and manufacturer instructions.\u003c\/p\u003e\n\u003cp\u003eBrowse our \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eelectrotherapy electrodes\u003c\/a\u003e or compare \u003ca href=\"https:\/\/www.balego.com\/products\/dura-stick-plus-tens-electrodes\"\u003eDURA-STICK Plus Electrodes\u003c\/a\u003e for compatible stimulation supplies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCombination therapy\u003c\/h1\u003e\n\u003cp\u003eThe 4738 Combo can deliver electrotherapy and ultrasound during the same treatment workflow. In a combination setup, the ultrasound applicator functions as part of the stimulation circuit while ultrasound energy is also being delivered.\u003c\/p\u003e\n\u003cp\u003eCombination treatment should be performed only by trained clinicians who understand:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStimulation-current settings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplicator movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContraindications for both modalities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatient monitoring and skin response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Combo model is a system for electrotherapy, ultrasound, and combined electrotherapy-ultrasound treatment. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eClinical protocol library\u003c\/h1\u003e\n\u003cp\u003eThe Transport 2 can store up to \u003cstrong\u003e15 user-created protocols\u003c\/strong\u003e. Depending on the selected model, stored protocols may include the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrotherapy parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined electrotherapy and ultrasound parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA clinician can save a customized setup and retrieve it during a later session. Parameters should still be reviewed before treatment because a saved protocol does not replace patient evaluation or professional judgment. \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWorkflow benefit\u003c\/th\u003e\n\u003cth\u003eHow protocol storage helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequently repeated treatments\u003c\/td\u003e\n\u003ctd\u003eReduces repeated manual setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-provider clinics\u003c\/td\u003e\n\u003ctd\u003eSupports more consistent parameter entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAthletic-training environments\u003c\/td\u003e\n\u003ctd\u003eMakes recurring setups easier to retrieve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination treatment\u003c\/td\u003e\n\u003ctd\u003eSaves both stimulation and ultrasound parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound-only clinics\u003c\/td\u003e\n\u003ctd\u003eStores preferred ultrasound settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eOptional battery and cart\u003c\/h1\u003e\n\u003ch2\u003eOptional lithium-ion battery\u003c\/h2\u003e\n\u003cp\u003eThe compatible \u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport%C2%AE-2-accessories\"\u003eIntelect Transport 2 Battery\u003c\/a\u003e is a self-contained lithium-ion module that charges automatically while the unit is connected to mains power. Chattanooga identifies it as compatible with both Transport 2 and Legend 2 systems. \u003c\/p\u003e\n\u003cp\u003eThe battery is optional and should not be described as included with either base configuration unless Balego creates a specific battery-bundle variant.\u003c\/p\u003e\n\u003ch2\u003eOptional magnetic cart\u003c\/h2\u003e\n\u003cp\u003eThe optional cart uses magnetic positioning to secure the system without a separate mounting adapter. It adds drawers, accessory storage, large wheels, and locking casters for clinic mobility.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetup\u003c\/th\u003e\n\u003cth\u003eBest suited for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTabletop unit\u003c\/td\u003e\n\u003ctd\u003eTreatment rooms with an existing counter or equipment table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit with battery\u003c\/td\u003e\n\u003ctd\u003eRoom-to-room or field-side use where wall power is inconvenient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit with cart\u003c\/td\u003e\n\u003ctd\u003eShared clinic system requiring organized accessory storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit with battery and cart\u003c\/td\u003e\n\u003ctd\u003eMaximum in-clinic mobility and cable flexibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eExpected package contents\u003c\/h1\u003e\n\u003ch2\u003e4782 Ultrasound package\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIntelect Transport 2 ultrasound units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 cm² ultrasound applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains power cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e4738 Combo package\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIntelect Transport 2 Combo unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e5 cm² ultrasound applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel 1 and 2 stimulation lead-wire kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour DURA-STICK Plus electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains power cord\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA standard 5 cm² applicator; current U.S. package listings also identify the stimulation leads and four DURA-STICK Plus electrodes with SKU 4738. \u003c\/p\u003e\n\u003cp\u003eThe following are optional unless a specific Balego bundle says otherwise:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLithium-ion battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTherapy cart\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 cm² applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10 cm² applicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement stimulation leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eElectrotherapy indications for the Combo model\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRelaxation of muscle spasm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevention or retardation of disuse atrophy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncreasing local blood circulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMuscle re-education\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintaining or increasing range of motion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSymptomatic relief or management of chronic intractable pain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjunctive treatment of post-traumatic pain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjunctive treatment of postsurgical pain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTherapeutic-ultrasound indications\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer describes therapeutic ultrasound as a source of deep heat for selected subacute and chronic conditions, including pain, muscle spasm, and joint contracture associated with soft-tissue and musculoskeletal conditions.\u003c\/p\u003e\n\u003cp\u003eTreatment appropriateness, parameters, and contraindications must be determined by the treating healthcare professional.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct comparisons\u003c\/h1\u003e\n\u003ch2\u003eIntelect Transport 2 Ultrasound vs. Combo\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport-2\"\u003eTransport 2 Ultrasound\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport-2\"\u003eTransport 2 Combo\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e4782\u003c\/td\u003e\n\u003ctd\u003e4738\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eTwo channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombination treatment\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveforms\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eFive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.2 lb\u003c\/td\u003e\n\u003ctd\u003e4.9 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard applicator\u003c\/td\u003e\n\u003ctd\u003e5 cm²\u003c\/td\u003e\n\u003ctd\u003e5 cm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eDedicated ultrasound workflow\u003c\/td\u003e\n\u003ctd\u003eClinics wanting ultrasound and stimulation in one device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTransport 2 Combo vs. Intelect Legend 2 Combo\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport-2\"\u003eIntelect Transport 2 Combo\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect%C2%AE-legend-2-4ch-combo\"\u003eIntelect Legend 2 Combo\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain positioning\u003c\/td\u003e\n\u003ctd\u003eCompact, portable essential-modality system\u003c\/td\u003e\n\u003ctd\u003eMore advanced clinic platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable stimulation channels\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003ctd\u003eTwo or four, depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy waveforms\u003c\/td\u003e\n\u003ctd\u003eFive\u003c\/td\u003e\n\u003ctd\u003eTwelve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003ctd\u003e1 and 3.3 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment setup\u003c\/td\u003e\n\u003ctd\u003eTraditional waveform and parameter selection\u003c\/td\u003e\n\u003ctd\u003eIncludes indication-based SPS setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuick-start protocols\u003c\/td\u003e\n\u003ctd\u003eUp to 15 stored user protocols\u003c\/td\u003e\n\u003ctd\u003eUp to 12 home-screen 2 \u0026amp; Go protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.6\" × 9.8\" × 4.7\"\u003c\/td\u003e\n\u003ctd\u003eApproximately 14\" × 13.4\" × 7.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.9 lb\u003c\/td\u003e\n\u003ctd\u003eApproximately 8.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional battery\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional magnetic cart\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003ePortability, athletic training and smaller treatment rooms\u003c\/td\u003e\n\u003ctd\u003eClinics needing broader waveform selection or four channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Legend 2 offers 12 waveforms, two- or four-channel configurations, an indication-based SPS treatment setup, and 2\u0026amp;Go shortcuts. The Transport 2 emphasizes a smaller footprint, lower weight, and five essential waveforms. \u003c\/p\u003e\n\u003ch2\u003eTransport 2 vs. original Intelect TranSport\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIntelect Transport 2\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intelect-transport\"\u003eOriginal Intelect TranSport\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct generation\u003c\/td\u003e\n\u003ctd\u003eThe current generation launched commercially in 2024\u003c\/td\u003e\n\u003ctd\u003ePrevious-generation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution color LCD\u003c\/td\u003e\n\u003ctd\u003eEarlier graphical LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCart connection\u003c\/td\u003e\n\u003ctd\u003eDirect magnetic mounting\u003c\/td\u003e\n\u003ctd\u003eOlder cart\/adapter workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eUpdated lithium-ion option\u003c\/td\u003e\n\u003ctd\u003ePrevious battery technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound coupling\u003c\/td\u003e\n\u003ctd\u003eImproved detection and monitoring\u003c\/td\u003e\n\u003ctd\u003eEarlier coupling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo waveforms\u003c\/td\u003e\n\u003ctd\u003eFive\u003c\/td\u003e\n\u003ctd\u003eModel-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct availability\u003c\/td\u003e\n\u003ctd\u003eCurrent Transport 2 family\u003c\/td\u003e\n\u003ctd\u003eLegacy system and remaining configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eEnovis introduced Transport 2 commercially in 2024 as the successor to the original Intelect TranSport family. \u003c\/p\u003e\n\u003ch2\u003eTransport 2 Combo vs. Vectra Neo\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTransport 2 Combo\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/chattanooga-vectra-neo-clinical-therapy-system\"\u003eVectra Neo\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eCompact portable system\u003c\/td\u003e\n\u003ctd\u003eModular clinical platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrotherapy channels\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003ctd\u003eConfiguration-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eAdded through selected configuration\/module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esEMG\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eAvailable by configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eAvailable by configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCart\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eCommon console\/cart workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eEssential stimulation and ultrasound with portability\u003c\/td\u003e\n\u003ctd\u003eClinics needing modular expansion and additional modalities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eWhich configuration should a clinic choose?\u003c\/h1\u003e\n\u003ch2\u003eChoose the 4782 ultrasound when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic needs dedicated therapeutic ultrasound.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrotherapy is already available from another device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA lighter 4.2-pound system is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePortability is more important than adding stimulation waveforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 5 cm² standard applicator fits most routine workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional 2 or 10 cm² applicators provide enough additional flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose the 4738 Combo when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBoth electrotherapy and ultrasound are used regularly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo stimulation channels are sufficient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombination treatment is part of the clinic’s workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVMS, interferential, premodulated, high-volt, and Russian waveforms meet the clinic’s needs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne portable device is preferred over separate stimulation and ultrasound systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants to store repeatable electrotherapy, ultrasound, and combination protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConsider the Legend 2 when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMore than two stimulation channels may be required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA broader selection of 12 electrotherapy waveforms is important.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAn indication-based SPS setup is desired.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHome-screen quick-start protocols are a priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA larger clinic platform is acceptable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eBasic ultrasound setup workflow\u003c\/h1\u003e\n\u003cp\u003eThis overview does not replace the operating manual.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the prescribed ultrasound frequency, intensity, duty cycle, treatment time, and applicator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the treatment site and applicator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a compatible ultrasound coupling medium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect either 1 or 3.3 MHz and choose the prescribed pulsed or continuous setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlace the applicator in complete contact with the treatment area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBegin the treatment and move the applicator according to clinical protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor the patient, coupling indicator, and treatment timer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStop treatment if contact is lost, discomfort occurs, or an error is displayed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean the applicator according to the manufacturer’s instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArrange annual calibration and manufacturer-authorized service as required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manual instructs users to understand the modality-specific indications, contraindications, warnings, and precautions before treating a patient. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSafety and professional-use notice\u003c\/h1\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThe Chattanooga Intelect Transport 2 is a professional clinical therapy system intended for use under the prescription and supervision of a licensed practitioner. Read the complete operating manual before use. Follow all electrotherapy and ultrasound indications, contraindications, precautions, electrode-placement instructions and applicator procedures. Do not use unauthorized accessories or operate the device in wet, oxygen-rich or flammable-anesthetic environments. Inspect electrodes, lead wires, applicators and cables before each treatment.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003eThe manual also cautions against using contaminated electrodes, leads, or gel; sharing electrodes between patients; allowing stimulation electrodes to touch during treatment; or using stimulation while bathing, showering, or in a sauna. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWarranty recommendation\u003c\/h1\u003e\n\u003cp\u003eThe manufacturer’s manual states:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePublished warranty\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntelect Transport 2 device\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e24 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead wires and electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e90 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTherapy cart\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound applicators\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is the Intelect Transport 2?\u003c\/h2\u003e\n\u003cp\u003eIt is a portable professional therapy system family available as a dedicated therapeutic ultrasound unit or a two-channel electrotherapy and ultrasound combo system. \u003c\/p\u003e\n\u003ch2\u003eWhat is the difference between models 4738 and 4782?\u003c\/h2\u003e\n\u003cp\u003eModel 4782 provides therapeutic ultrasound only. Model 4738 adds two stimulation channels, five electrotherapy waveforms, and electrotherapy-ultrasound combination treatment.\u003c\/p\u003e\n\u003ch2\u003eDoes the Combo model include ultrasound?\u003c\/h2\u003e\n\u003cp\u003eYes. It includes the same dual-frequency ultrasound capability and the standard 5 cm² applicator category as the ultrasound model.\u003c\/p\u003e\n\u003ch2\u003eWhat electrotherapy waveforms are included?\u003c\/h2\u003e\n\u003cp\u003eThe combo includes VMS, interferential, premodulated, high-volt, and Russian stimulation. \u003c\/p\u003e\n\u003ch2\u003eIs TENS available?\u003c\/h2\u003e\n\u003cp\u003eTENS and NMES applications within the electrotherapy capabilities of the Combo. The user selects the appropriate waveform and parameters rather than choosing a single generic “TENS” button. \u003c\/p\u003e\n\u003ch2\u003eHow many stimulation channels does the Combo have?\u003c\/h2\u003e\n\u003cp\u003eTwo.\u003c\/p\u003e\n\u003ch2\u003eWhat ultrasound frequencies are available?\u003c\/h2\u003e\n\u003cp\u003eThe technical specifications identify 1 MHz and 3.3 MHz operation. \u003c\/p\u003e\n\u003ch2\u003eDoes it provide pulsed ultrasound?\u003c\/h2\u003e\n\u003cp\u003eYes. Available duty-cycle choices include 10%, 20%, 50%, and continuous output.\u003c\/p\u003e\n\u003ch2\u003eWhich applicator comes standard?\u003c\/h2\u003e\n\u003cp\u003eThe 5 cm² applicator is the standard general-purpose applicator. Optional 2 cm² and 10 cm² applicators are available.\u003c\/p\u003e\n\u003ch2\u003eDoes it detect poor ultrasound coupling?\u003c\/h2\u003e\n\u003cp\u003eYes. The coupling-detection settings can provide an audible alert and stop or pause timer progression when suitable applicator contact is interrupted. \u003c\/p\u003e\n\u003ch2\u003eIs the battery included?\u003c\/h2\u003e\n\u003cp\u003eThe rechargeable lithium-ion battery is optional unless Balego specifically creates a battery-included bundle.\u003c\/p\u003e\n\u003ch2\u003eHow long does the optional battery operate?\u003c\/h2\u003e\n\u003cp\u003eThe operating manual states approximately 1.5–3 hours per full charge, depending on the applicator and pulsed mode.\u003c\/p\u003e\n\u003ch2\u003eDoes the battery charge inside the device?\u003c\/h2\u003e\n\u003cp\u003eYes. It charges automatically while mains power is connected. The device defaults to mains power when plugged in.\u003c\/p\u003e\n\u003ch2\u003eIs a cart required?\u003c\/h2\u003e\n\u003cp\u003eNo. The device can be used on a suitable tabletop. The optional cart provides magnetic mounting, drawers, and room-to-room mobility.\u003c\/p\u003e\n\u003ch2\u003eHow many custom protocols can be saved?\u003c\/h2\u003e\n\u003cp\u003eUp to 15 user-created protocols. \u003c\/p\u003e\n\u003ch2\u003eCan ultrasound and electrotherapy be used together?\u003c\/h2\u003e\n\u003cp\u003eYes, but only on the 4738 Combo model and according to the combination treatment instructions.\u003c\/p\u003e\n\u003ch2\u003eIs this an at-home ultrasound machine?\u003c\/h2\u003e\n\u003cp\u003eNo. Chattanooga identifies it as professional equipment reserved for healthcare professionals and used under appropriate supervision. \u003c\/p\u003e\n\u003ch2\u003eDoes it include electrodes?\u003c\/h2\u003e\n\u003cp\u003eCurrent U.S. package listings for the 4738 Combo include stimulation lead wires and four DURA-STICK Plus electrodes. The 4782 ultrasound model does not require stimulation electrodes. Confirm current package contents before fulfillment. \u003c\/p\u003e\n\u003ch2\u003eWhat is the device warranty?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer manual specifies a two-year device warranty, with separate shorter periods for accessories, applicators, and the cart. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/which-modalities-to-use\"\u003eWhich therapy modality should you use?\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/device-user-manual-setup-safety-and-specs\"\u003eDevice Manuals, Setup, Safety and Specifications\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Chattanooga Group","offers":[{"title":"4782 – Intelect Transport 2 Ultrasound | Ultrasound Only","offer_id":48722383634687,"sku":"4782","price":1299.0,"currency_code":"USD","in_stock":true},{"title":"4738 – Intelect Transport 2 Combo | 2-Channel E-Stim + Ultrasound","offer_id":48722383601919,"sku":"4738","price":2699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Chattanooga_Intelect_Transport_2_Combo_electrotherapy_and_ultrasound_system.jpg?v=1784758429","url":"https:\/\/balego-stores.myshopify.com\/products\/intelect-transport-2","provider":"Balego","version":"1.0","type":"link"}