{"product_id":"intensity-2-inch-square-tens-electrodes","title":"Richmar InTENSity 2\" × 2\" White Cloth TENS Electrodes — 40 Pack","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_c7f6d42e7f3835d4\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003ch2\u003eRichmar InTENSity 2\" × 2\" White Cloth Electrodes — 40 Pack\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRichmar InTENSity 2\" × 2\" White Cloth Electrodes\u003c\/strong\u003e are reusable, self-adhering replacement pads for compatible TENS, EMS\/NMES, interferential, and related electrotherapy devices.\u003c\/p\u003e\n\u003cp\u003eEach electrode combines a flexible conductive carbon layer with self-adhering hydrogel, a soft white cloth backing, and a reinforced full-coverage wire connection. The square 2-inch profile provides a practical balance between focused placement and useful surface coverage, making it one of the most versatile electrode sizes for portable electrotherapy.\u003c\/p\u003e\n\u003cp\u003eThis product has \u003cstrong\u003e10 individually sealed packages of four electrodes\u003c\/strong\u003e, for a total of \u003cstrong\u003e40 reusable pads\u003c\/strong\u003e. The bulk configuration is useful for clinics, rehabilitation departments, chiropractic offices, sports-medicine programs, athletic-training rooms, and home users who want multiple replacement sets available.\u003c\/p\u003e\n\u003cp\u003eThe EP2020WC2-INTM electrode is a standard accessory with several InTENSity devices, including the \u003ca href=\"https:\/\/www.balego.com\/products\/intensity-10-tens-device\"\u003eInTENSity 10\u003c\/a\u003e, \u003ca href=\"https:\/\/www.balego.com\/products\/intensity-12-tens-device\"\u003eInTENSity 12\u003c\/a\u003e, \u003ca href=\"https:\/\/www.balego.com\/products\/twin-stim-iv-portable-tens-unit\"\u003eTwin Stim IV\u003c\/a\u003e, \u003ca href=\"https:\/\/www.balego.com\/products\/intensity-select-combo-ii\"\u003eSelect Combo II\u003c\/a\u003e, and \u003ca href=\"https:\/\/www.balego.com\/products\/if-combo-ii-portable-tens-device\"\u003eIF Combo II\u003c\/a\u003e. \u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e2\" × 2\" square electrotherapy electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e40 total electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10 separately sealed packs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e4 electrodes in each pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReusable, self-adhering construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible conductive carbon layer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductive hydrogel skin interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSoft white cloth backing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReinforced full-coverage wire connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with many TENS devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with qualifying EMS and NMES units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with qualifying interferential stimulators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard pin-style electrotherapy connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer-listed reuse of up to 15 applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for home and professional electrotherapy workflows\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe carbon layer supports broad current delivery across the pad and identifies the electrodes for TENS, EMS, interferential, and other compatible electrostimulation applications. \u003c\/p\u003e\n\u003ch2\u003eSpecifications at a glance\u003c\/h2\u003e\n\u003ctable style=\"width: 100.036%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 42.0712%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"width: 57.7131%;\"\u003eProduct detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eRichmar InTENSity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eProduct number\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eEP2020WC2 \u0026amp; EP2020WC2-INTM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eProduct type\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eReusable self-adhering electrotherapy electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eElectrode size\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003e2\" × 2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eMetric size\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eApproximately 5.1 × 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eShape\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eSquare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eBacking\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eWhite cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eConductive structure\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eFlexible carbon layer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eSkin interface\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eSelf-adhering conductive hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eConnection\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003ePigtail-style socket for compatible pin leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eBalego-listed electrode connection\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eStandard 2 mm female socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eCommon modalities\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eTENS, EMS\/NMES and interferential stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eElectrodes per pouch\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eNumber of pouches\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eTotal electrodes\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eManufacturer reuse statement\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eUp to 15 applications under suitable conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eExtra conductive gel needed\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eNormally no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eStorage\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eOn original liner inside sealed pouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 42.0712%;\"\u003eReusable between patients\u003c\/td\u003e\n\u003ctd style=\"width: 57.7131%;\"\u003eNo, assign each set to one person\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe pad connection is a standard 2 mm female pigtail socket. Pairs EP2020WC2-INTM electrodes with \u003ca href=\"https:\/\/www.balego.com\/products\/45-inch-tens-nmes-lead-wires\"\u003eWW3005 lead wires \u003c\/a\u003eon several InTENSity systems; those leads terminate in standard 2 mm electrode pins. \u003c\/p\u003e\n\u003ch1\u003eWhat comes in the 40-electrode package?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage level\u003c\/th\u003e\n\u003cth align=\"right\"\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrodes in each sealed pouch\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealed pouches supplied\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical dual-channel four-pad setups represented\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 fresh sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe separately packaged four-electrode sets allow unused pads to remain sealed until they are needed. This is particularly useful in clinical settings where each pouch can be assigned to one patient.\u003c\/p\u003e\n\u003ch1\u003eWhy choose a 2\" × 2\" electrode?\u003c\/h1\u003e\n\u003cp\u003eThe 2-inch square format is a common general-purpose size because it provides more surface area than a small targeted electrode without requiring the space of a long rectangular pad.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode size or shape\u003c\/th\u003e\n\u003cth align=\"right\"\u003eRelative coverage\u003c\/th\u003e\n\u003cth\u003ePractical fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.25\"–1.5\" square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSmall\u003c\/td\u003e\n\u003ctd\u003eCompact treatment sites and closely spaced placements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\" round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSmall to medium\u003c\/td\u003e\n\u003ctd\u003eCurved regions and smaller joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2\" × 2\" square\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003eMedium\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose TENS, NMES, and IFC placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\" × 3.5\" rectangle\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMedium to large\u003c\/td\u003e\n\u003ctd\u003eBroader muscles and treatment regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\" × 4\" rectangle or oval\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eLarge\u003c\/td\u003e\n\u003ctd\u003eLarger muscle groups and broad-area stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOversized back electrode\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eVery large\u003c\/td\u003e\n\u003ctd\u003eSpecialized lumbar or thoracic setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOur \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/buy-tens-electrodes-guide\"\u003eTENS electrode buying guide\u003c\/a\u003e identifies the 2\" square format as a useful starting point for many everyday replacement-electrode applications.\u003c\/p\u003e\n\u003ch2\u003eAdvantages of the square profile\u003c\/h2\u003e\n\u003cp\u003eA square electrode can be positioned\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBeside another pad in a two-electrode setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAround a painful region in a four-pad TENS arrangement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver a motor-point region for clinician-directed NMES\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIn a crossed interferential configuration when permitted by the device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOn many common arm, shoulder, back, hip, thigh, and leg treatment sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlacement must still follow the electrotherapy device instructions and any directions supplied by the treating healthcare professional. Richmar notes that electrode placement is an important treatment parameter and advises users to follow the prescribed location and device instructions.\u003c\/p\u003e\n\u003ch1\u003eHow the electrode layers work\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode component\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003ePractical benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhite cloth backing\u003c\/td\u003e\n\u003ctd\u003eProvides the outer support layer\u003c\/td\u003e\n\u003ctd\u003eFlexible, comfortable surface that follows ordinary contours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive carbon layer\u003c\/td\u003e\n\u003ctd\u003eDistributes electrical output through the pad\u003c\/td\u003e\n\u003ctd\u003eHelps avoid concentrating all output at the wire connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive hydrogel\u003c\/td\u003e\n\u003ctd\u003eTransfers current between the pad and skin\u003c\/td\u003e\n\u003ctd\u003eProvides both conductivity and adhesion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-coverage wire connection\u003c\/td\u003e\n\u003ctd\u003eConnects the pigtail lead across the conductive layer\u003c\/td\u003e\n\u003ctd\u003eHelps support durable, consistent connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePigtail socket\u003c\/td\u003e\n\u003ctd\u003eReceives the electrotherapy lead-wire pin\u003c\/td\u003e\n\u003ctd\u003eAllows connection to compatible standard-pin lead wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective liner\u003c\/td\u003e\n\u003ctd\u003eCovers the gel between treatments\u003c\/td\u003e\n\u003ctd\u003eHelps reduce contamination and premature drying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResealable pouch\u003c\/td\u003e\n\u003ctd\u003eProtects the stored set\u003c\/td\u003e\n\u003ctd\u003eHelps preserve gel moisture and cleanliness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe flexible carbon layer, premium white cloth backing, self-adhering construction, and full-coverage wire connector are the product’s principal design features. \u003c\/p\u003e\n\u003ch1\u003eCompatible electrotherapy modalities\u003c\/h1\u003e\n\u003ch2\u003eTENS\u003c\/h2\u003e\n\u003cp\u003eTENS generally uses sensory-level electrical stimulation for temporary pain modulation programs. The desired sensation is typically strong but comfortable tingling, pulsing, or buzzing without a forceful muscle contraction.\u003c\/p\u003e\n\u003cp\u003eBrowse Balego’s \u003ca href=\"https:\/\/www.balego.com\/collections\/tens\"\u003eTENS units, electrodes, and accessories\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eEMS and NMES\u003c\/h2\u003e\n\u003cp\u003eEMS and NMES use electrical pulses to activate motor nerves and produce a visible or palpable muscle contraction. These electrodes may be used when the stimulator accepts the connection and permits a 2\" square pad.\u003c\/p\u003e\n\u003cp\u003eCompare devices in our \u003ca href=\"https:\/\/www.balego.com\/collections\/neuromuscular-stimulation\"\u003eneuromuscular stimulation collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor a clearer explanation of treatment goals, read \u003ca href=\"https:\/\/www.balego.com\/blogs\/which-modalities-to-use\/tens-vs-nmes\"\u003eTENS vs. NMES: Differences, Uses, and Device Guide\u003c\/a\u003e. \u003c\/p\u003e\n\u003ch2\u003eInterferential stimulation\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer identifies these pads for compatible IF or interferential applications. Confirm that the clinical or portable interferential system uses the correct lead-wire connection and permits electrodes of this size. \u003c\/p\u003e\n\u003ch2\u003eOther electrostimulation devices\u003c\/h2\u003e\n\u003cp\u003eDo not assume that every electrical-stimulation system accepts these pads. Microcurrent, FES, Russian stimulation, combination systems, clinical stimulators, and specialized devices may have different electrode or connection requirements.\u003c\/p\u003e\n\u003ch1\u003eLead-wire compatibility\u003c\/h1\u003e\n\u003cp\u003eThe electrode does not connect directly to the stimulation unit. Its pigtail socket accepts the pin at the electrode end of a compatible lead wire.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility point\u003c\/th\u003e\n\u003cth\u003eWhat to verify\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode connection\u003c\/td\u003e\n\u003ctd\u003eThe lead wire terminates in a compatible 2 mm pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice connection\u003c\/td\u003e\n\u003ctd\u003eThe opposite plug fits the stimulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-wire condition\u003c\/td\u003e\n\u003ctd\u003eNo exposed wire, cracking, looseness or intermittent output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode size\u003c\/td\u003e\n\u003ctd\u003eThe stimulator or clinician permits a 2\" square electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment modality\u003c\/td\u003e\n\u003ctd\u003eThe electrode is appropriate for the selected stimulation mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel setup\u003c\/td\u003e\n\u003ctd\u003eThe correct number of electrodes is connected to each channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOur \u003ca href=\"https:\/\/www.balego.com\/products\/45-inch-tens-nmes-lead-wires\"\u003e45-inch TENS\/NMES lead wires\u003c\/a\u003e use a 2.35 mm device-side plug and standard 2 mm electrode pins. They fit many Richmar and portable electrotherapy devices.\u003c\/p\u003e\n\u003ch2\u003eThese electrodes generally will not directly fit:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSnap-style electrode cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTab or clip-style leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProprietary EMPI safety connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMagnetic connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWireless wearable TENS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOmron-style proprietary pad connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductive garments without the required adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems with permanently attached electrode pads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor additional connector guidance, read \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/tens-nmes-electrode-connectors-pigtail-vs-tab\"\u003eTENS and NMES Electrode Connectors: Pigtail vs. Tab\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch1\u003eHow to apply InTENSity electrodes\u003c\/h1\u003e\n\u003cp\u003eAlways follow the instructions supplied with the electrotherapy device.\u003c\/p\u003e\n\u003ch2\u003e1. Turn the stimulator off\u003c\/h2\u003e\n\u003cp\u003eSet the output intensity to zero and turn the unit off before connecting, applying, repositioning, or removing the electrodes.\u003c\/p\u003e\n\u003ch2\u003e2. Inspect the electrodes\u003c\/h2\u003e\n\u003cp\u003eDo not use a pad with the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDry or visibly damaged gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA torn backing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA loose pigtail connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA folded or permanently curled edge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposed conductive material\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirt, lint or hair covering the gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdhesion too weak to maintain complete skin contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe electrode instructions advise inspecting the wires and adhesive before every use and immediately discarding electrodes that are damaged or no longer adhere firmly. \u003c\/p\u003e\n\u003ch2\u003e3. Prepare the skin\u003c\/h2\u003e\n\u003cp\u003eApply electrodes to clean, dry, intact skin.\u003c\/p\u003e\n\u003cp\u003eRemove:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLotion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBody oil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSweat\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMakeup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTopical analgesic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoose debris\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClean, dry skin supports more complete adhesion and consistent contact. Richmar’s electrode-placement guidance specifically directs users to apply electrodes to clean and dry skin.\u003c\/p\u003e\n\u003ch2\u003e4. Connect the lead wire\u003c\/h2\u003e\n\u003cp\u003eInsert the compatible lead-wire pin completely into the pigtail socket.\u003c\/p\u003e\n\u003cp\u003eDo not pull, twist, or bend the pigtail excessively.\u003c\/p\u003e\n\u003ch2\u003e5. Remove the pad from its liner\u003c\/h2\u003e\n\u003cp\u003eLift the electrode by the cloth edge rather than pulling on the pigtail wire.\u003c\/p\u003e\n\u003cp\u003eAvoid touching the hydrogel more than necessary.\u003c\/p\u003e\n\u003ch2\u003e6. Apply the complete electrode\u003c\/h2\u003e\n\u003cp\u003ePosition the pad and smooth it from the center outward. Make sure the gel surface lies flat without:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAir pockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWrinkles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFolded corners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifted edges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHair trapped beneath the pad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e7. Begin at zero intensity\u003c\/h2\u003e\n\u003cp\u003eTurn on the device and gradually increase the output according to the treatment plan.\u003c\/p\u003e\n\u003cp\u003eStimulation should not feel sharply concentrated, burning, painful, or intolerable. Stop and inspect the electrode when one edge feels substantially stronger than the rest.\u003c\/p\u003e\n\u003ch2\u003e8. Turn the device off before removal\u003c\/h2\u003e\n\u003cp\u003eReduce intensity to zero and turn the stimulator off. Never pull an electrode from the skin while stimulation remains active. \u003c\/p\u003e\n\u003ch2\u003e9. Return the pad to the liner\u003c\/h2\u003e\n\u003cp\u003ePeel the electrode slowly from its cloth edge and place the gel side back onto its original protective liner.\u003c\/p\u003e\n\u003ch2\u003e10. Reseal the pouch\u003c\/h2\u003e\n\u003cp\u003eReturn all four electrodes to their pouch and close it securely.\u003c\/p\u003e\n\u003ch1\u003eElectrode life and reuse\u003c\/h1\u003e\n\u003cp\u003eThese electrodes may be reused up to 15 times. That is a maximum under suitable conditions—not a guarantee that every set will last for exactly 15 treatments. \u003c\/p\u003e\n\u003cp\u003eActual life varies according to the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSkin cleanliness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSkin oil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerspiration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBody hair\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency of use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment duration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandling of the hydrogel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExposure to air\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDust and lint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBody location\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEdge movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntensity and treatment setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReplace the electrodes when adhesion or electrical comfort declines, even when fewer than 15 applications have occurred.\u003c\/p\u003e\n\u003ch2\u003eWhen should the pads be replaced?\u003c\/h2\u003e\n\u003cp\u003eReplace a set when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAn electrode does not remain completely attached.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne or more corners repeatedly lift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe hydrogel has dried.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe gel is dirty, uneven, or contaminated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe backing is torn.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe pigtail connector is loose.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStimulation feels sharper or more concentrated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput becomes weak or intermittent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSkin irritation develops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe pad has been used by another person.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA worn pad may still look usable while providing incomplete contact. Poor contact can produce an uneven sensation and may increase the likelihood of skin irritation.\u003c\/p\u003e\n\u003ch1\u003eElectrode size safety\u003c\/h1\u003e\n\u003cp\u003eUse the same electrode size originally supplied with the device unless another size is approved by the clinician or device instructions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA smaller electrode can increase current concentration and the chance of irritation or burns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA substantially larger electrode may reduce perceived stimulation, prompting the user to increase intensity unnecessarily.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement electrodes should match the original size or the healthcare professional’s recommendation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhenever changing electrode size, brand, gel type, or placement, return the intensity to zero and readjust gradually.\u003c\/p\u003e\n\u003ch1\u003eShould additional electrode gel be used?\u003c\/h1\u003e\n\u003cp\u003eNormally, no.\u003c\/p\u003e\n\u003cp\u003eThese are self-adhering pre-gelled electrodes. Adding electrode gel, water, lotion, or another contact medium may:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eReduce adhesion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMake the electrode slide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContaminate the existing hydrogel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCause uneven contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShorten useful life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeparate conductive gel is more appropriate for non-gelled carbon-rubber electrodes. Customers who need that type of setup can compare our \u003ca href=\"https:\/\/www.balego.com\/products\/carbon-rubber-electrodes\"\u003enon-gelled carbon electrodes\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch1\u003eCare and storage\u003c\/h1\u003e\n\u003cp\u003eAfter each treatment:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eTurn off the stimulator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove each pad by its cloth edge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid pulling the pigtail connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReturn the pads to the original liner.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlace the complete set in its pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeal the pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStore according to the package directions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep the set assigned to one person.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eDo not:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWash or soak the pad.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScrape the hydrogel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean it with alcohol or solvent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeave it uncovered between treatments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStore it in direct sunlight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFold the electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCut the pad into another shape.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShare it between patients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eProduct comparison\u003c\/h1\u003e\n\u003ch2\u003eInTENSity vs. other 2\" square Balego electrodes\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intensity-2-inch-square-tens-electrodes\"\u003eInTENSity White Cloth Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tens-electrodes\"\u003eBalego TENS\/NMES\/FES Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/bulk-tens-electrodes\"\u003eEveryway KF5050 Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/starburst-electrodes\"\u003eStarburst Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard size\u003c\/td\u003e\n\u003ctd\u003e2\" × 2\"\u003c\/td\u003e\n\u003ctd\u003e2\" × 2\" plus other sizes\u003c\/td\u003e\n\u003ctd\u003e50 × 50 mm \/ about 2\" square\u003c\/td\u003e\n\u003ctd\u003e2\" square plus other shapes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e40 total\u003c\/td\u003e\n\u003ctd\u003e4 per package\u003c\/td\u003e\n\u003ctd\u003e16 or 200 total\u003c\/td\u003e\n\u003ctd\u003e4 per package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eWhite cloth\u003c\/td\u003e\n\u003ctd\u003eSpun-lace topcoat\u003c\/td\u003e\n\u003ctd\u003eWhite fabric\u003c\/td\u003e\n\u003ctd\u003eSoft electrode backing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive layer\u003c\/td\u003e\n\u003ctd\u003eFlexible carbon\u003c\/td\u003e\n\u003ctd\u003eConductive carbon film\u003c\/td\u003e\n\u003ctd\u003eConductive electrode body\u003c\/td\u003e\n\u003ctd\u003eSilver-gradient pattern over carbon film\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel\u003c\/td\u003e\n\u003ctd\u003eInTENSity hydrogel\u003c\/td\u003e\n\u003ctd\u003e0.040\" reusable hydrogel\u003c\/td\u003e\n\u003ctd\u003eSekisui Japanese gel\u003c\/td\u003e\n\u003ctd\u003e0.040\" aloe hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003ePigtail socket for 2 mm pin\u003c\/td\u003e\n\u003ctd\u003eSoft-molded pigtail socket\u003c\/td\u003e\n\u003ctd\u003ePigtail socket for 2 mm pin\u003c\/td\u003e\n\u003ctd\u003eSoft-molded pigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer reuse statement\u003c\/td\u003e\n\u003ctd\u003eUp to 15 applications\u003c\/td\u003e\n\u003ctd\u003eDepends on use and care\u003c\/td\u003e\n\u003ctd\u003eDepends on use and care\u003c\/td\u003e\n\u003ctd\u003eDepends on use and care\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry positioning\u003c\/td\u003e\n\u003ctd\u003eRichmar product\u003c\/td\u003e\n\u003ctd\u003eMade in USA with American raw materials\u003c\/td\u003e\n\u003ctd\u003eEveryway product\u003c\/td\u003e\n\u003ctd\u003eUni-Patch premium design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eCost-effective bulk stocking\u003c\/td\u003e\n\u003ctd\u003eEveryday USA-made replacement pad\u003c\/td\u003e\n\u003ctd\u003eSmall or high-volume clinic purchasing\u003c\/td\u003e\n\u003ctd\u003ePremium current-distribution design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChoose InTENSity electrodes when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou need 40 standard-size pads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA clinic wants 10 separately packaged four-pad sets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhite cloth construction is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe stimulator accepts standard 2 mm electrode pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTENS, EMS\/NMES, or interferential compatibility is needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-effective bulk replacement supply is the priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eInTENSity electrodes and compatible Richmar devices\u003c\/h1\u003e\n\u003cp\u003eThe EP2020WC2-INTM is the standard electrode supplied with several portable devices.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice\u003c\/th\u003e\n\u003cth\u003eModalities\u003c\/th\u003e\n\u003cth\u003eBalego link\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInTENSity Select Combo II\u003c\/td\u003e\n\u003ctd\u003eTENS, NMES, IFC, and Russian\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intensity-select-combo-ii\"\u003eView Select Combo II\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwin Stim IV\u003c\/td\u003e\n\u003ctd\u003eTENS and NMES\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/twin-stim-iv-portable-tens-unit\"\u003eView Twin Stim IV\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInTENSity IF Combo II\u003c\/td\u003e\n\u003ctd\u003eTENS and IFC\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/interferential\"\u003eBrowse TENS and IFC devices\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther portable pin-lead stimulators\u003c\/td\u003e\n\u003ctd\u003eDevice-dependent\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-devices\"\u003eBrowse electrotherapy devices\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eHow many electrodes are included?\u003c\/h2\u003e\n\u003cp\u003eThe package contains 40 electrodes: 10 sealed pouches with four pads in each pouch. \u003c\/p\u003e\n\u003ch2\u003eWhat size are the pads?\u003c\/h2\u003e\n\u003cp\u003eEach electrode measures 2\" × 2\", approximately 5.1 × 5.1 cm.\u003c\/p\u003e\n\u003ch2\u003eAre these reusable?\u003c\/h2\u003e\n\u003cp\u003eYes. They can be reused up to 15 times. Actual service life varies, and the pads should be replaced earlier when they are dirty, damaged, dry, uncomfortable, or unable to adhere completely. \u003c\/p\u003e\n\u003ch2\u003eWhy did the previous page say 5–10 uses?\u003c\/h2\u003e\n\u003cp\u003eThat was a conservative estimate in the Balego copy. The current manufacturer specification states up to 15 uses, so the product table and FAQ should be updated to reflect the documented maximum while explaining that results vary.\u003c\/p\u003e\n\u003ch2\u003eWhat connector do they use?\u003c\/h2\u003e\n\u003cp\u003eBalego lists a standard 2 mm female pigtail socket. It accepts a compatible male electrode pin at the end of the lead wire.\u003c\/p\u003e\n\u003ch2\u003eWill these fit every TENS unit?\u003c\/h2\u003e\n\u003cp\u003eNo. They fit many devices using standard 2 mm pin leads, but they will not directly fit proprietary snap, tab, magnetic, wireless, EMPI safety, or Omron-style connections.\u003c\/p\u003e\n\u003ch2\u003eCan they be used with the Balego TENS unit?\u003c\/h2\u003e\n\u003cp\u003eThey may be used when the Balego device and its lead wires terminate in compatible standard 2 mm electrode pins. Always check both the device-side and electrode-side connections.\u003c\/p\u003e\n\u003ch2\u003eCan they be used with NMES?\u003c\/h2\u003e\n\u003cp\u003eYes, when the NMES or EMS device accepts the connector and permits a 2\" square electrode. Richmar lists this electrode family for EMS applications. \u003c\/p\u003e\n\u003ch2\u003eCan they be used for interferential stimulation?\u003c\/h2\u003e\n\u003cp\u003eYes, with compatible interferential equipment and lead wires. The manufacturer includes IF among the supported applications.\u003c\/p\u003e\n\u003ch2\u003eAre these snap electrodes?\u003c\/h2\u003e\n\u003cp\u003eNo. They use a pigtail socket rather than a metal snap.\u003c\/p\u003e\n\u003ch2\u003eDo they require separate electrode gel?\u003c\/h2\u003e\n\u003cp\u003eNo additional gel is normally required. Conductive adhesive hydrogel is already incorporated into the pad.\u003c\/p\u003e\n\u003ch2\u003eCan the pads be cut?\u003c\/h2\u003e\n\u003cp\u003eNo. Cutting changes the conductive surface area and may create uneven current distribution or expose internal materials.\u003c\/p\u003e\n\u003ch2\u003eCan several patients share a pouch?\u003c\/h2\u003e\n\u003cp\u003eNo. Once opened and used, a reusable set should remain assigned to one patient.\u003c\/p\u003e\n\u003ch2\u003eWhy does stimulation sometimes feel sharper with an old pad?\u003c\/h2\u003e\n\u003cp\u003eDryness, contamination, lifted edges, or partial adhesion can reduce the effective contact area and concentrate the sensation. Turn off the device, inspect the electrode, and replace it when full contact cannot be restored.\u003c\/p\u003e\n\u003ch2\u003eWhy does a fresh electrode sometimes feel stronger?\u003c\/h2\u003e\n\u003cp\u003eA fresh hydrogel surface may provide more complete contact than an older pad. More consistent contact can make the same device setting feel more distinct.\u003c\/p\u003e\n\u003ch2\u003eShould the skin be cleaned with alcohol?\u003c\/h2\u003e\n\u003cp\u003eFollow the device and electrode instructions. The principal requirement is clean, dry, intact skin without lotion, oil, or sweat. Allow any permitted cleanser to evaporate fully before applying the pad.\u003c\/p\u003e\n\u003ch2\u003eCan the electrodes be applied over topical pain cream?\u003c\/h2\u003e\n\u003cp\u003eNo. Topical creams, oils, lotions, and analgesic products may interfere with adhesion and electrical contact.\u003c\/p\u003e\n\u003ch2\u003eCan the pads be used in water?\u003c\/h2\u003e\n\u003cp\u003eNo. Do not operate electrotherapy equipment in a shower, bath, swimming pool, or other wet environment.\u003c\/p\u003e\n\u003ch2\u003eWhat if the electrode will not stick?\u003c\/h2\u003e\n\u003cp\u003eClean and dry the skin, check for lotion or hair, and inspect the gel. Replace the pad when it remains loose or repeatedly lifts.\u003c\/p\u003e\n\u003ch2\u003eWhat if one channel does not work?\u003c\/h2\u003e\n\u003cp\u003eCheck:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eThe device intensity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-wire connection at the stimulator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoth electrode pins\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePad adhesion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-wire condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSubstitute a known-good lead or electrode set to identify whether the problem is the pad, wire, or device.\u003c\/p\u003e\n\u003ch1\u003eWhy purchase InTENSity electrodes from Balego?\u003c\/h1\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/products\/intensity-2-inch-square-tens-electrodes\"\u003eRichmar InTENSity 2\" × 2\" White Cloth Electrodes\u003c\/a\u003e provide 10 individually packaged sets for home users, clinics, physical therapy departments, chiropractic offices, sports medicine programs, and rehabilitation facilities.\u003c\/p\u003e\n\u003cp\u003eCustomers can also:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBrowse all \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/tens-electrodes\"\u003eBalego TENS\/NMES\/FES Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/bulk-tens-electrodes\"\u003eEveryway KF5050 2\" Square Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/starburst-electrodes\"\u003eStarburst Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShop \u003ca href=\"https:\/\/www.balego.com\/products\/45-inch-tens-nmes-lead-wires\"\u003e45-inch TENS and NMES lead wires\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead the \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/buy-tens-electrodes-guide\"\u003eTENS Electrode Buying Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead the \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/tens-nmes-electrode-connectors-pigtail-vs-tab\"\u003ePigtail vs. Tab Connector Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExplore the complete \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-guides\"\u003eTENS Education Library\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e for compatibility assistance\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Richmar","offers":[{"title":"Default Title","offer_id":47299515613439,"sku":"EP2020WC2","price":15.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Richmar_InTENSity_2_x_2_white_cloth_TENS_electrodes.jpg?v=1784601312","url":"https:\/\/balego-stores.myshopify.com\/products\/intensity-2-inch-square-tens-electrodes","provider":"Balego","version":"1.0","type":"link"}