{"product_id":"iogel-iontophoresis-electrodes","title":"Chattanooga IOGEL Iontophoresis Electrodes — 12 Treatment Kits","description":"\u003ch2\u003eIOGEL® Disposable Iontophoresis Electrodes — 12 Treatment Kits\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iogel-iontophoresis-electrodes\"\u003eIOGEL Iontophoresis Electrodes\u003c\/a\u003e are single-use drug-delivery electrode kits for professional iontophoresis treatments using a compatible external dose controller.\u003c\/p\u003e\n\u003cp\u003eThe elongated elliptical design helps clinicians position the active electrode along a tendon or other narrow treatment region. A clear adhesive border makes it easier to see the target site during placement, while the protected EZ Fill Window allows the GelSponge medication reservoir to be filled before the adhesive liner is removed.\u003c\/p\u003e\n\u003cp\u003eIOGEL uses a silver\/silver chloride conductive element designed to stabilize pH without a separate chemical buffer. Its GelSponge interface helps maintain complete contact between the medication reservoir and intact skin while providing a low-impedance conductive medium.\u003c\/p\u003e\n\u003cp\u003eEach box contains \u003cstrong\u003e12 individually packaged treatment kits\u003c\/strong\u003e. Every kit includes:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded component\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrug-delivery electrode\u003c\/td\u003e\n\u003ctd\u003eHolds the prescribed ionized medication or solution at the treatment site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposable dispersive electrode\u003c\/td\u003e\n\u003ctd\u003eCompletes the electrical circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol prep\u003c\/td\u003e\n\u003ctd\u003eCleans and prepares the two electrode sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMedication, a dose controller, controller lead wires, and any required snap adapters are not included. \u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional-use notice:\u003c\/strong\u003e Iontophoresis medication, polarity, current, total dose, treatment duration, and electrode placement must be determined by an appropriately qualified healthcare professional and used according to the medication, electrode, and dose-controller instructions.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDisposable iontophoresis drug-delivery electrode kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 complete treatment kits per box\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree fill-volume options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElliptical active-electrode shape\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned to follow the line of a tendon\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClear adhesive for accurate target-site placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSilver\/silver chloride conductive element\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003epH stabilization without a separate chemical buffer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGelSponge conductive skin interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEZ Fill Window protects the adhesive during filling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo-stick handling before placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrug electrode and dispersive electrode included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlcohol prep included with every kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStud or snap-style connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntended for compatible external iontophoresis controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-use only\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eIOGEL sizes and fill volumes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer number\u003c\/th\u003e\n\u003cth\u003eSize\u003c\/th\u003e\n\u003cth align=\"right\"\u003eFill volume\u003c\/th\u003e\n\u003cth align=\"right\"\u003eApproximate length\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePackage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5000021\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmall\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5 cc\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5 in.\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5000022\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5 cc\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5 in.\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5000023\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLarge\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3.5 cc\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3.5 in.\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhich IOGEL size should you choose?\u003c\/h1\u003e\n\u003cp\u003eThe appropriate size depends on the prescribed medication volume, treatment site dimensions, skin contour, and clinician’s intended current density and dosing plan.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical need\u003c\/th\u003e\n\u003cth\u003ePotential size choice\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall or narrow treatment region\u003c\/td\u003e\n\u003ctd\u003eSmall 1.5 cc\u003c\/td\u003e\n\u003ctd\u003eCompact active electrode and lower reservoir volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral tendon or soft-tissue placement\u003c\/td\u003e\n\u003ctd\u003eMedium 2.5 cc\u003c\/td\u003e\n\u003ctd\u003eMidrange size and volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroader treatment site or greater solution volume\u003c\/td\u003e\n\u003ctd\u003eLarge 3.5 cc\u003c\/td\u003e\n\u003ctd\u003eLargest IOGEL reservoir and adhesive footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHighly curved or irregular anatomy\u003c\/td\u003e\n\u003ctd\u003eConsider \u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion electrodes\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eForm-fitting construction may adapt better to uneven anatomy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly-shaped placement needed\u003c\/td\u003e\n\u003ctd\u003eConsider \u003ca href=\"https:\/\/www.balego.com\/products\/ionto4-iontophoresis-electrodes\"\u003eIonto4 electrodes\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIncludes a butterfly configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo external dose controller desired\u003c\/td\u003e\n\u003ctd\u003eConsider \u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH\u003c\/a\u003e or \u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSelf-contained wearable patch format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not select a larger electrode merely because it holds more medication. The prescribed dose, compatible solution volume, current, polarity, and treatment area must be considered together.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow IOGEL electrode technology works\u003c\/h1\u003e\n\u003ch2\u003eSilver\/silver chloride conductive element\u003c\/h2\u003e\n\u003cp\u003eIOGEL uses silver\/silver chloride rather than a basic carbon-only conductor. Chattanooga states that this technology conducts more efficiently than carbon and helps stabilize pH without chemical buffers. \u003c\/p\u003e\n\u003cp\u003eDuring direct-current iontophoresis, chemical changes can occur at the electrode interfaces. Proper pH control, complete contact, correct polarity, and appropriate current density are important for comfort and skin safety.\u003c\/p\u003e\n\u003ch2\u003eGelSponge interface\u003c\/h2\u003e\n\u003cp\u003eThe GelSponge reservoir absorbs the prescribed solution and maintains contact between the medication and the skin. Chattanooga describes it as providing a conductive medium similar to ultrasound gel and helping create complete skin contact with low impedance. \u003c\/p\u003e\n\u003ch2\u003eEZ Fill Window\u003c\/h2\u003e\n\u003cp\u003eThe EZ Fill Window allows the clinician to hydrate the drug reservoir while the adhesive remains protected. This can help reduce the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMedication contacting the adhesive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePremature sticking during preparation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContamination from unnecessary handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeakage before the electrode is placed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoss of adhesion during setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eClear elliptical adhesive\u003c\/h2\u003e\n\u003cp\u003eThe clear adhesive helps the clinician see the target location, while the elongated profile is designed to follow the general direction of a tendon. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eIOGEL vs. other iontophoresis electrodes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iogel-iontophoresis-electrodes\"\u003eIOGEL\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ionto4-iontophoresis-electrodes\"\u003eIonto4\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontophoresis-electrodes\"\u003eBalego Buffered Electrode Kit\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eExternal dose controller\u003c\/td\u003e\n\u003ctd\u003eExternal dose controller\u003c\/td\u003e\n\u003ctd\u003eExternal dose controller\u003c\/td\u003e\n\u003ctd\u003eExternal dose controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKits per box\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrug electrode technology\u003c\/td\u003e\n\u003ctd\u003eSilver\/silver chloride\u003c\/td\u003e\n\u003ctd\u003eCarbon–Ag\/AgCl\u003c\/td\u003e\n\u003ctd\u003eCarbon–Ag\/AgCl\u003c\/td\u003e\n\u003ctd\u003eAg\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn electrode\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eBuffered return included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol prep\u003c\/td\u003e\n\u003ctd\u003e1 per kit\u003c\/td\u003e\n\u003ctd\u003e1 per kit\u003c\/td\u003e\n\u003ctd\u003e1 per kit\u003c\/td\u003e\n\u003ctd\u003e2 per kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFill options\u003c\/td\u003e\n\u003ctd\u003e1.5, 2.5, 3.5 cc\u003c\/td\u003e\n\u003ctd\u003e1.5, 2.0, 2.0 butterfly, 3.5 cc\u003c\/td\u003e\n\u003ctd\u003e1.5, 2.5, 2.0 butterfly, 4.0 cc\u003c\/td\u003e\n\u003ctd\u003e1.5, 2.5, 2.0 butterfly, 4.0 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape emphasis\u003c\/td\u003e\n\u003ctd\u003eElliptical, tendon-following\u003c\/td\u003e\n\u003ctd\u003eFlexible and form-fitting\u003c\/td\u003e\n\u003ctd\u003eSquare and butterfly choices\u003c\/td\u003e\n\u003ctd\u003eSquare and butterfly choices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFill-window design\u003c\/td\u003e\n\u003ctd\u003eEZ Fill Window\u003c\/td\u003e\n\u003ctd\u003eProduct-specific matrix\u003c\/td\u003e\n\u003ctd\u003eAbsorbent matrix\u003c\/td\u003e\n\u003ctd\u003eProduct-specific reservoir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eStraightforward tendon-oriented placement\u003c\/td\u003e\n\u003ctd\u003eCurved or uneven anatomical sites\u003c\/td\u003e\n\u003ctd\u003eClinics wanting square and butterfly options\u003c\/td\u003e\n\u003ctd\u003eClinics wanting buffered return and two prep pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCurrent Balego listings identify Trivarion as a form-fitting option for curved anatomy, Ionto4 as a four-shape carbon–Ag\/AgCl system, and the buffered kit as an Ag\/AgCl option with a buffered return electrode and two prep pads.\u003c\/p\u003e\n\u003ch2\u003eChoose Trivarion when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment site is curved or irregular.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA flexible, form-fitting electrode is a priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2.0 cc butterfly option is useful.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic uses the \u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\"\u003eActivaDose II controller\u003c\/a\u003e or another confirmed compatible system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Ionto4 when\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSquare electrode geometry is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 4.0 cc large option is needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA butterfly electrode is part of the clinic’s workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCarbon–Ag\/AgCl electrode construction is specified.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eController-based IOGEL vs. wearable iontophoresis patches\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIOGEL with dose controller\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eSeparate external controller\u003c\/td\u003e\n\u003ctd\u003eIntegrated into patch\u003c\/td\u003e\n\u003ctd\u003eIntegrated into patch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead wires\u003c\/td\u003e\n\u003ctd\u003eRequired\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment location\u003c\/td\u003e\n\u003ctd\u003eNormally clinic-based while connected\u003c\/td\u003e\n\u003ctd\u003eWearable outside clinic\u003c\/td\u003e\n\u003ctd\u003eWearable outside clinic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent control\u003c\/td\u003e\n\u003ctd\u003eSet by clinician on controller\u003c\/td\u003e\n\u003ctd\u003eControlled by patch design\u003c\/td\u003e\n\u003ctd\u003eControlled by patch design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment time\u003c\/td\u003e\n\u003ctd\u003eDetermined by prescribed dose and current\u003c\/td\u003e\n\u003ctd\u003eApproximately 4–14 hours depending on model\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.25–12 hours depending on model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBox quantity\u003c\/td\u003e\n\u003ctd\u003e12 treatment kits\u003c\/td\u003e\n\u003ctd\u003e6 kits\u003c\/td\u003e\n\u003ctd\u003e6 kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize choices\u003c\/td\u003e\n\u003ctd\u003eSmall, medium, large\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003ctd\u003eModel-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eDirect clinician control and shorter connected treatment\u003c\/td\u003e\n\u003ctd\u003eSelf-contained wearable delivery\u003c\/td\u003e\n\u003ctd\u003eMultiple self-powered treatment-time choices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIontoPATCH and ACTIVApatch use self-contained power systems and do not require an external controller or lead wires. IOGEL is a traditional controller-based electrode system. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCompatible iontophoresis equipment\u003c\/h1\u003e\n\u003cp\u003eIOGEL uses stud or snap connections and is marketed for use with Chattanooga iontophoresis equipment. Before ordering, verify:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility question\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController type\u003c\/td\u003e\n\u003ctd\u003eThe device is designed specifically for iontophoresis drug delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead wires\u003c\/td\u003e\n\u003ctd\u003eController lead wires terminate in compatible clips or snap adapters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eThe drug electrode is connected to the polarity required by the prescribed medication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range\u003c\/td\u003e\n\u003ctd\u003eThe controller can deliver the clinician-prescribed direct current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose control\u003c\/td\u003e\n\u003ctd\u003eThe device can deliver the prescribed mA-minute dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode size\u003c\/td\u003e\n\u003ctd\u003eThe selected reservoir volume fits the prescribed solution and treatment site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice instructions\u003c\/td\u003e\n\u003ctd\u003eIOGEL or an equivalent electrode style is permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\"\u003eActivaDose II Dose Controller\u003c\/a\u003e is a current controller option with adjustable direct current and dose settings.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow to prepare and apply IOGEL electrodes\u003c\/h1\u003e\n\u003cp\u003eThe following is a general overview. The current electrode instructions, controller manual, medication labeling, prescription, and facility procedure take priority.\u003c\/p\u003e\n\u003ch2\u003e1. Confirm the treatment order\u003c\/h2\u003e\n\u003cp\u003eVerify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMedication or solution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrug polarity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal dose in mA·min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive-electrode site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispersive-electrode site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment duration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatient contraindications and precautions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Inspect the skin\u003c\/h2\u003e\n\u003cp\u003eUse only on intact skin. Do not place the electrodes over:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbrasions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRazor nicks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive rashes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePimples or ingrown hairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInfected tissue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnhealed wounds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecent scar tissue unless specifically cleared\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur detailed \u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\"\u003eIontophoresis Electrode Directions for Use\u003c\/a\u003e provides additional site preparation, polarity, dosing, and safety guidance.\u003c\/p\u003e\n\u003ch2\u003e3. Remove nearby jewelry\u003c\/h2\u003e\n\u003cp\u003eRemove jewelry or metal objects that could touch either electrode or lie in the current pathway.\u003c\/p\u003e\n\u003ch2\u003e4. Prepare both sites\u003c\/h2\u003e\n\u003cp\u003eUse the included alcohol prep according to the electrode instructions. Clean the active and dispersive sites and allow them to dry fully before application.\u003c\/p\u003e\n\u003ch2\u003e5. Fill the drug electrode away from the patient\u003c\/h2\u003e\n\u003cp\u003ePlace the electrode on a flat working surface with the reservoir facing upward.\u003c\/p\u003e\n\u003cp\u003eOpen the EZ Fill Window and apply the prescribed volume of compatible water-soluble medication or solution evenly across the GelSponge.\u003c\/p\u003e\n\u003cp\u003eDo not:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFill the electrode while it is on the patient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLeave dry areas in the sponge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverfill the reservoir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnderfill the reservoir.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse a suspended or non-water-soluble preparation unless specifically permitted.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAllow medication to spread onto the adhesive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e6. Apply the dispersive electrode first\u003c\/h2\u003e\n\u003cp\u003ePlace the return or dispersive electrode at the prescribed site and press across its entire adhesive surface.\u003c\/p\u003e\n\u003cp\u003eAvoid bony prominences with minimal soft tissue unless the clinician and product directions specifically permit the location.\u003c\/p\u003e\n\u003ch2\u003e7. Apply the drug-delivery electrode\u003c\/h2\u003e\n\u003cp\u003eRemove the protective liner and use the clear adhesive to align the GelSponge precisely over the target.\u003c\/p\u003e\n\u003cp\u003ePress the adhesive border—not the filled reservoir—onto the skin. Pressing directly over the sponge can encourage leakage.\u003c\/p\u003e\n\u003ch2\u003e8. Connect the lead wires\u003c\/h2\u003e\n\u003cp\u003eConnect the drug and dispersive electrodes to the dose controller with the correct polarity.\u003c\/p\u003e\n\u003cp\u003eFor a negatively charged medication:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDrug electrode: black or negative\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispersive electrode: red or positive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a positively charged medication:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDrug electrode: red or positive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDispersive electrode: black or negative\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe polarity of the drug must be verified from the prescription, medication information, and clinical protocol. (\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\" title=\"Iontophoresis Electrodes—Directions for Use… | Balego\"\u003eBalego\u003c\/a\u003e)\u003c\/p\u003e\n\u003ch2\u003e9. Deliver the prescribed treatment\u003c\/h2\u003e\n\u003cp\u003eSet the exact dose and current ordered for the patient. Monitor comfort, electrode contact, skin response, lead-wire security, and controller alerts.\u003c\/p\u003e\n\u003cp\u003eOur current directions identify a 4 mA maximum and polarity-dependent maximum doses of 80 mA·min for negative-polarity delivery and 40 mA·min for positive-polarity delivery. The current product and controller instructions should always control. (\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\" title=\"Iontophoresis Electrodes—Directions for Use… | Balego\"\u003eBalego\u003c\/a\u003e)\u003c\/p\u003e\n\u003ch2\u003e10. Remove and discard\u003c\/h2\u003e\n\u003cp\u003eAfter the controller completes its ramp-down:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eTurn off or disconnect the controller as directed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove the drug electrode slowly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove the dispersive electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect both skin sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscard both electrodes and the used prep material.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocument the dose, current, medication, placement, and skin response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch1\u003eSafety information\u003c\/h1\u003e\n\u003cp\u003eIontophoresis should not be used when the patient has a known adverse reaction to electrical current, an electrically sensitive implanted device such as a pacemaker, or a known sensitivity to the prescribed medication. It should not be applied over damaged skin, across the chest, transcranially, or in the orbital region. \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety concern\u003c\/th\u003e\n\u003cth\u003eRecommended action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePain or burning\u003c\/td\u003e\n\u003ctd\u003eStop current immediately and inspect both electrode sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncreasing stinging\u003c\/td\u003e\n\u003ctd\u003eReduce or stop treatment according to clinical protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication leakage\u003c\/td\u003e\n\u003ctd\u003eStop, dry the skin, and correct the electrode setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifted adhesive edge\u003c\/td\u003e\n\u003ctd\u003eStop and restore safe contact with a new kit if necessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController reject alarm\u003c\/td\u003e\n\u003ctd\u003eInspect lead connections, electrode contact, skin preparation, and movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcessive redness\u003c\/td\u003e\n\u003ctd\u003eDiscontinue and assess the skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlistering or burn\u003c\/td\u003e\n\u003ctd\u003eStop treatment and provide appropriate clinical evaluation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnown drug sensitivity\u003c\/td\u003e\n\u003ctd\u003eDo not administer the medication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacemaker or sensitive implant\u003c\/td\u003e\n\u003ctd\u003eDo not use unless specifically permitted under appropriate medical direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamaged pouch or electrode\u003c\/td\u003e\n\u003ctd\u003eDiscard and use a new sealed kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreviously used electrode\u003c\/td\u003e\n\u003ctd\u003eDo not reuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcess patient movement\u003c\/td\u003e\n\u003ctd\u003eReposition and secure the setup; movement can disrupt contact and leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTemporary redness can occur under either electrode, but pain, intense burning, blistering, or progressive irritation is not an expected treatment goal and requires prompt assessment. (\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\" title=\"Iontophoresis Electrodes—Directions for Use… | Balego\"\u003eBalego\u003c\/a\u003e)\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTroubleshooting\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended response\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication leaks before placement\u003c\/td\u003e\n\u003ctd\u003eThe reservoir was overfilled or pressed\u003c\/td\u003e\n\u003ctd\u003eDiscard when contact or dosing integrity is uncertain; refill a new electrode correctly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive will not stick\u003c\/td\u003e\n\u003ctd\u003eMedication contacted adhesive or skin was not dry\u003c\/td\u003e\n\u003ctd\u003ePrepare a new dry site and use a fresh kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGelSponge has dry spots\u003c\/td\u003e\n\u003ctd\u003eInsufficient or uneven filling\u003c\/td\u003e\n\u003ctd\u003eHydrate evenly with the prescribed volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController displays reject or high resistance\u003c\/td\u003e\n\u003ctd\u003ePoor skin contact, disconnected lead, dry reservoir, or contaminated connector\u003c\/td\u003e\n\u003ctd\u003eStop and inspect the complete circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe patient feels a sharp sting\u003c\/td\u003e\n\u003ctd\u003eEdge lift, incomplete hydration, high current density, or skin defect\u003c\/td\u003e\n\u003ctd\u003eStop immediately and inspect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive electrode moves\u003c\/td\u003e\n\u003ctd\u003eSite contour, movement, or compromised adhesive\u003c\/td\u003e\n\u003ctd\u003eDo not tape or compress unless the IFU permits it; replace when secure contact cannot be maintained\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo current flows\u003c\/td\u003e\n\u003ctd\u003eIncorrect lead connection, open circuit, or controller issue\u003c\/td\u003e\n\u003ctd\u003eVerify polarity, snaps, leads, electrode contact, and controller setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment takes longer than expected\u003c\/td\u003e\n\u003ctd\u003eCurrent has been reduced by the controller because of resistance\u003c\/td\u003e\n\u003ctd\u003eInspect contact and follow device troubleshooting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcessive redness under one pad\u003c\/td\u003e\n\u003ctd\u003eContact or current density may be uneven\u003c\/td\u003e\n\u003ctd\u003eDiscontinue and assess before further treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe unused kit appears dry or damaged\u003c\/td\u003e\n\u003ctd\u003ePackage integrity or storage issue\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat are IOGEL electrodes?\u003c\/h2\u003e\n\u003cp\u003eIOGEL electrodes are disposable drug-delivery and dispersive-electrode kits used with compatible external iontophoresis controllers. They are available in 1.5, 2.5, and 3.5 cc sizes.\u003c\/p\u003e\n\u003ch2\u003eAre IOGEL electrodes discontinued?\u003c\/h2\u003e\n\u003cp\u003eYes.\u003c\/p\u003e\n\u003ch2\u003eHow many treatments are in a box?\u003c\/h2\u003e\n\u003cp\u003eEach box contains 12 individually packaged treatment kits. \u003c\/p\u003e\n\u003ch2\u003eWhat is included in each treatment kit?\u003c\/h2\u003e\n\u003cp\u003eEach kit includes one medication-delivery electrode, one disposable dispersive electrode, and one alcohol prep.\u003c\/p\u003e\n\u003ch2\u003eIs medication included?\u003c\/h2\u003e\n\u003cp\u003eNo. Medication or solution is not included.\u003c\/p\u003e\n\u003ch2\u003eWhat fill volumes are available?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSmall: 1.5 cc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedium: 2.5 cc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge: 3.5 cc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat does the GelSponge do?\u003c\/h2\u003e\n\u003cp\u003eIt absorbs the prescribed solution, maintains contact with the skin, and provides a low-impedance conductive interface. \u003c\/p\u003e\n\u003ch2\u003eWhat is the EZ Fill Window?\u003c\/h2\u003e\n\u003cp\u003eIt is a protected opening that allows the medication reservoir to be filled before exposing the adhesive. This helps simplify handling and reduces the possibility of medication contaminating the adhesive.\u003c\/p\u003e\n\u003ch2\u003eWhy is the adhesive clear?\u003c\/h2\u003e\n\u003cp\u003eThe transparent border allows the clinician to see the target site during application and position the reservoir more precisely.\u003c\/p\u003e\n\u003ch2\u003eWhy is the electrode elliptical?\u003c\/h2\u003e\n\u003cp\u003eThe elongated shape is designed to follow the line of a tendon and fit narrow treatment regions.\u003c\/p\u003e\n\u003ch2\u003eCan IOGEL be used with a TENS machine?\u003c\/h2\u003e\n\u003cp\u003eNo. A TENS unit does not provide the same controlled direct-current drug-delivery function as an iontophoresis dose controller.\u003c\/p\u003e\n\u003ch2\u003eCan IOGEL pads replace ordinary TENS electrodes?\u003c\/h2\u003e\n\u003cp\u003eNo. They are single-use medication-delivery electrodes, not reusable sensory- or muscle-stimulation pads.\u003c\/p\u003e\n\u003ch2\u003eDoes IOGEL require a controller?\u003c\/h2\u003e\n\u003cp\u003eYes. It requires a compatible external iontophoresis dose controller and lead-wire system.\u003c\/p\u003e\n\u003ch2\u003eCan it be used with the ActivaDose II?\u003c\/h2\u003e\n\u003cp\u003eThe ActivaDose II is a professional iontophoresis controller, but the clinic should confirm the electrode snaps, lead-wire adapters, prescribed dose, and manufacturer compatibility before use.\u003c\/p\u003e\n\u003ch2\u003eAre IOGEL electrodes reusable?\u003c\/h2\u003e\n\u003cp\u003eNo. Both electrodes are single-use and should be discarded after treatment.\u003c\/p\u003e\n\u003ch2\u003eCan the reservoir be filled while it is on the patient?\u003c\/h2\u003e\n\u003cp\u003eNo. Prepare and fill the drug electrode on a flat surface before application.\u003c\/p\u003e\n\u003ch2\u003eCan any medication be used?\u003c\/h2\u003e\n\u003cp\u003eNo. Use only a medication or compatible water-soluble solution prescribed and approved for the specific iontophoresis treatment.\u003c\/p\u003e\n\u003ch2\u003eHow much current should be used?\u003c\/h2\u003e\n\u003cp\u003eCurrent and total doses are prescribed patient-specific treatment parameters. Do not choose a setting based solely on the electrode size or its maximum capability.\u003c\/p\u003e\n\u003ch2\u003eWhat should the patient feel?\u003c\/h2\u003e\n\u003cp\u003eA mild electrical sensation may occur, but treatment should not cause significant pain, burning, or a sharp localized sensation.\u003c\/p\u003e\n\u003ch2\u003eWhy does the controller show a reject warning?\u003c\/h2\u003e\n\u003cp\u003ePossible causes include incomplete electrode contact, patient movement, a disconnected lead, dirty or corroded connectors, inadequate reservoir hydration, or excessive skin resistance. (\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\" title=\"Iontophoresis Electrodes—Directions for Use… | Balego\"\u003eBalego\u003c\/a\u003e)\u003c\/p\u003e\n\u003ch2\u003eCan the electrodes be taped down?\u003c\/h2\u003e\n\u003cp\u003eBalego’s current directions advise against taping, binding, or compressing the electrodes during treatment. Follow the current IOGEL IFU and facility protocol. (\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\" title=\"Iontophoresis Electrodes—Directions for Use… | Balego\"\u003eBalego\u003c\/a\u003e)\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCurrent alternatives while IOGEL is unavailable\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eNeed\u003c\/th\u003e\n\u003cth\u003eRecommended Balego alternative\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClosest traditional controller-based workflow\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ionto4-iontophoresis-electrodes\"\u003eIonto4 Iontophoresis Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible placement on curves or joints\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion Iontophoresis Kits\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered return-electrode kit\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontophoresis-electrodes\"\u003eBalego Iontophoresis Electrode Kit\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-contained wearable patch\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH STAT, 80, and Extra Strength\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiple wireless treatment-time options\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch IntelliDose and IontoGo\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement professional controller\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\"\u003eActivaDose II Dose Controller\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull category comparison\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/iontophoresis\"\u003eIontophoresis Collection\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/iontophoresis\"\u003eIontophoresis Products and Patches\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\/iontophoresis-electrodes-directions-for-use\"\u003eIontophoresis Electrode Directions for Use\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ionto4-iontophoresis-electrodes\"\u003eIonto4 Iontophoresis Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/trivarion-iontophoresis\"\u003eTrivarion Iontophoresis Delivery Kits\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontophoresis-electrodes\"\u003eBuffered Iontophoresis Electrode Kit\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\"\u003eActivaDose II Dose Controller\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/iontopatch\"\u003eIontoPATCH Products\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/activapatch\"\u003eACTIVApatch Products\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-faq\"\u003eIontophoresis FAQ Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"IOMED","offers":[{"title":"5000021 - Small (1.5 cc)","offer_id":48860639494399,"sku":null,"price":102.95,"currency_code":"USD","in_stock":false},{"title":"5000022 - Medium (2.5 cc)","offer_id":48860639527167,"sku":null,"price":102.95,"currency_code":"USD","in_stock":false},{"title":"5000023 - Large (3.5 cc)","offer_id":48860639559935,"sku":null,"price":102.95,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Iogel-Iontophoresis-Electrodes.webp?v=1784609718","url":"https:\/\/balego-stores.myshopify.com\/products\/iogel-iontophoresis-electrodes","provider":"Balego","version":"1.0","type":"link"}