{"product_id":"ionto4-iontophoresis-electrodes","title":"Ionto4™ Iontophoresis Electrodes | Drug-Delivery Electrode Treatment Kits, 12\/Box","description":"\u003cdiv dir=\"ltr\" id=\"model-response-message-contentr_fba40f1824620837\" class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_2189815b4b8263e2\" dir=\"ltr\"\u003e\n\u003cp\u003eThe Ionto4™ Iontophoretic Delivery Kit is a single-use drug-delivery electrode system for professional iontophoresis treatments with FDA-cleared constant-current iontophoresis devices. Available from Balego, Ionto4™ kits combine an active drug electrode, a return\/ground electrode, and an alcohol prep pad in individually packaged treatment kits.\u003c\/p\u003e\n\u003cp\u003eEach Ionto4™ electrode is designed with carbon-Ag\/AgCl technology, an absorbent drug matrix, a large adhesive surface area, and medical-grade materials not made with natural rubber latex. The collection is available in three square sizes plus a butterfly shape, giving clinicians flexibility when selecting drug reservoir volume, treatment-area fit, and electrode footprint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eIonto4™ is a drug-delivery iontophoresis electrode treatment kit intended for administering soluble salts or other medications into the body for medical purposes as an alternative to hypodermic injection when used under proper professional direction.\u003c\/p\u003e\n\u003cp\u003eEach box includes \u003cstrong\u003e12 individual treatment kits\u003c\/strong\u003e. Each treatment pouch contains:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Item\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne active drug electrode\u003c\/td\u003e\n\u003ctd\u003eHolds the medication or solution for iontophoresis delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne return \/ ground electrode\u003c\/td\u003e\n\u003ctd\u003eCompletes the treatment circuit and supports patient comfort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne alcohol prep pad\u003c\/td\u003e\n\u003ctd\u003eUsed to clean the skin before electrode placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe system is designed for use with FDA-cleared, constant-current iontophoresis devices. \u003cem\u003eMedication is not included.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose Ionto4™ Iontophoresis Electrodes?\u003c\/h2\u003e\n\u003ch3\u003eSingle-Use Treatment Kits\u003c\/h3\u003e\n\u003cp\u003eEach pouch contains the components needed for one treatment setup: active electrode, ground electrode, and alcohol wipe. Single-use packaging supports clean, organized treatment-room workflow.\u003c\/p\u003e\n\u003ch3\u003eCarbon-Ag\/AgCl Technology\u003c\/h3\u003e\n\u003cp\u003eIonto4™ electrodes use carbon-Ag\/AgCl, or carbon silver\/silver chloride, technology designed for maximum strength and precise buffering during iontophoresis treatment.\u003c\/p\u003e\n\u003ch3\u003eHighly Absorbent Drug Matrix\u003c\/h3\u003e\n\u003cp\u003eThe active electrode includes a highly absorbent matrix designed to hold the drug or solution evenly after proper hydration.\u003c\/p\u003e\n\u003ch3\u003eLarge Adhesive Surface Area\u003c\/h3\u003e\n\u003cp\u003eEach electrode has a large adhesive surface area to help support secure placement during treatment.\u003c\/p\u003e\n\u003ch3\u003eComfort-Focused Ground Electrode\u003c\/h3\u003e\n\u003cp\u003eThe large ground electrode surface area is designed to lower sensation and increase patient comfort during use.\u003c\/p\u003e\n\u003ch3\u003eMultiple Shapes and Fill Volumes\u003c\/h3\u003e\n\u003cp\u003eChoose from Small, Medium, Large, and Butterfly options depending on fill volume, placement area, and clinical workflow.\u003c\/p\u003e\n\u003ch3\u003eNot Made With Natural Rubber Latex\u003c\/h3\u003e\n\u003cp\u003eBoth electrodes are not manufactured with natural rubber latex and are made with biocompatible materials.\u003c\/p\u003e\n\u003ch3\u003eOrder from Balego\u003c\/h3\u003e\n\u003cp\u003eBuy Ionto4™ iontophoresis electrodes from Balego for professional therapy product sourcing, free USA shipping, and Balego’s best-price guarantee.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSize and SKU Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003cth\u003eSize \/ Shape\u003c\/th\u003e\n\u003cth\u003eSize Label\u003c\/th\u003e\n\u003cth align=\"right\"\u003eDrug Matrix Fill Volume\u003c\/th\u003e\n\u003cth\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC89375\u003c\/td\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd\u003eSmall Square 2.75\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5cc\u003c\/td\u003e\n\u003ctd\u003eSmaller treatment areas or lower fill-volume needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC89376\u003c\/td\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd\u003eMedium Square 3.25\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5cc\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose iontophoresis workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC89377\u003c\/td\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd\u003eLarge Square 3.5\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.0 cc\u003c\/td\u003e\n\u003ctd\u003eLarger drug matrix volume and broader placement area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC89378\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd\u003eButterfly 3.75\" × 3.3\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003eContoured placement areas where butterfly shape may fit better\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eBest Ionto4™ Option by Clinical Need\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical Need\u003c\/th\u003e\n\u003cth\u003eRecommended Option\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSKU\u003c\/th\u003e\n\u003cth\u003eWhy It Fits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest drug matrix volume\u003c\/td\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89375\u003c\/td\u003e\n\u003ctd\u003e1.5cc fill volume for smaller applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalanced everyday option\u003c\/td\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89376\u003c\/td\u003e\n\u003ctd\u003e2.5cc fill volume for general treatment setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLargest reservoir volume\u003c\/td\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89377\u003c\/td\u003e\n\u003ctd\u003e4.0 cc fill volume for larger matrix capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContoured fit\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89378\u003c\/td\u003e\n\u003ctd\u003eA 2.0 cc butterfly shape can help with placement around certain areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree square size choices\u003c\/td\u003e\n\u003ctd\u003eSmall, Medium, or Large\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89375–NC89377\u003c\/td\u003e\n\u003ctd\u003eLets clinicians choose by surface area and drug matrix volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-square layout\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNC89378\u003c\/td\u003e\n\u003ctd\u003eUseful when a traditional square electrode is not the preferred fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Comparison: Small vs. Medium vs. Large vs. Butterfly\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSmall Square\u003c\/th\u003e\n\u003cth\u003eMedium Square\u003c\/th\u003e\n\u003cth\u003eLarge Square\u003c\/th\u003e\n\u003cth\u003eButterfly\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eNC89375\u003c\/td\u003e\n\u003ctd\u003eNC89376\u003c\/td\u003e\n\u003ctd\u003eNC89377\u003c\/td\u003e\n\u003ctd\u003eNC89378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFill volume\u003c\/td\u003e\n\u003ctd\u003e1.5cc\u003c\/td\u003e\n\u003ctd\u003e2.5cc\u003c\/td\u003e\n\u003ctd\u003e4.0 cc\u003c\/td\u003e\n\u003ctd\u003e2.0 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e2.75\"\u003c\/td\u003e\n\u003ctd\u003e3.25\"\u003c\/td\u003e\n\u003ctd\u003e3.5\"\u003c\/td\u003e\n\u003ctd\u003e3.75\" × 3.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBox quantity\u003c\/td\u003e\n\u003ctd\u003e12 kits\u003c\/td\u003e\n\u003ctd\u003e12 kits\u003c\/td\u003e\n\u003ctd\u003e12 kits\u003c\/td\u003e\n\u003ctd\u003e12 kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive electrode included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround \/ return electrode included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol prep pad included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest use case\u003c\/td\u003e\n\u003ctd\u003eSmaller placement needs\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose use\u003c\/td\u003e\n\u003ctd\u003eLarger reservoir needs\u003c\/td\u003e\n\u003ctd\u003eContoured placement needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eHow to Choose the Right Ionto4™ Size\u003c\/h2\u003e\n\u003ch3\u003eChoose Small Square, NC89375, if:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou need the smallest listed drug matrix volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a compact square electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area is smaller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 1.5cc fill volume is appropriate for the clinical plan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose Medium Square, NC89376, if:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a balanced general-purpose option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need more fill volume than Small but less than Large.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2.5cc fill volume matches the treatment plan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYour clinic wants a versatile square electrode option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose Large Square, NC89377, if\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou need the largest listed drug matrix volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou prefer a broader square footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 4.0cc fill volume is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area and device setup allow for a larger electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose Butterfly, NC89378, if:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a non-square shape.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2.0cc fill volume is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe placement area may benefit from a contoured butterfly design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA square electrode is not the best fit for the selected site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIonto4™ Technology and Material Features\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eBenefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon-Ag\/AgCl technology\u003c\/td\u003e\n\u003ctd\u003eCarbon silver\/silver chloride electrode design\u003c\/td\u003e\n\u003ctd\u003eSupports precise buffering and consistent iontophoresis performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHighly absorbent drug matrix\u003c\/td\u003e\n\u003ctd\u003eAn active electrode matrix holds medication or solution\u003c\/td\u003e\n\u003ctd\u003eHelps distribute the drug or solution across the matrix after proper hydration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge adhesive area\u003c\/td\u003e\n\u003ctd\u003eBroad surface adhesion area\u003c\/td\u003e\n\u003ctd\u003eHelps maintain contact during treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge ground electrode\u003c\/td\u003e\n\u003ctd\u003eThe return electrode has a larger surface area\u003c\/td\u003e\n\u003ctd\u003eHelps lower sensation and improve comfort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypoallergenic materials\u003c\/td\u003e\n\u003ctd\u003eMade of non-sensitizing medical-grade materials\u003c\/td\u003e\n\u003ctd\u003eSupports professional treatment-room use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot made with natural rubber latex\u003c\/td\u003e\n\u003ctd\u003eElectrodes are not manufactured with natural rubber latex\u003c\/td\u003e\n\u003ctd\u003eHelps support latex-sensitive environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual treatment pouches\u003c\/td\u003e\n\u003ctd\u003eEach kit is individually packaged\u003c\/td\u003e\n\u003ctd\u003eSimplifies treatment setup and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eTreatment Setup Summary\u003c\/h2\u003e\n\u003cp\u003eAlways follow the full IFU and the iontophoresis device manual. This summary is for education and should not replace the manufacturer instructions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eStep\u003c\/th\u003e\n\u003cth\u003eSetup Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eRead the iontophoresis device manual before treatment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eUse only with FDA-cleared, constant-current iontophoresis devices.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd\u003eRemove one active drug electrode, one ground electrode, and one alcohol wipe from the pouch.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eClean both electrode placement sites thoroughly with the alcohol wipe.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e5\u003c\/td\u003e\n\u003ctd\u003eHydrate the drug delivery matrix with the required dosage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e6\u003c\/td\u003e\n\u003ctd\u003eDo not underfill or overfill the matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e7\u003c\/td\u003e\n\u003ctd\u003eMake sure no dry spots are visible before application.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e8\u003c\/td\u003e\n\u003ctd\u003eRemove the liner and place the active electrode on the treatment area without compressing the drug matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e9\u003c\/td\u003e\n\u003ctd\u003ePlace the ground electrode on a major muscle 4\"–6\" away from the active electrode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e10\u003c\/td\u003e\n\u003ctd\u003eAttach lead wires according to medication polarity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e11\u003c\/td\u003e\n\u003ctd\u003eSet the iontophoresis unit to the prescribed total charge and current level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003ctd\u003eTurn the unit off before removing electrodes after treatment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eFill Volume Guide\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode Option\u003c\/th\u003e\n\u003cth align=\"right\"\u003eRequired Matrix Hydration Volume\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.0 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not overfill or underfill the drug delivery matrix. Avoid dry spots. If dry spots are visible, lightly touch up the matrix with the syringe tip until the dry areas are gone.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003ePolarity Connection Guide\u003c\/h2\u003e\n\u003cp\u003eConnect lead wires according to the polarity of the drug or solution being delivered.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDrug \/ Polarity\u003c\/th\u003e\n\u003cth\u003eDrug Electrode Lead\u003c\/th\u003e\n\u003cth\u003eGround Electrode Lead\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNegative\u003c\/td\u003e\n\u003ctd\u003eBlack, negative\u003c\/td\u003e\n\u003ctd\u003eRed, positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003ctd\u003eRed, positive\u003c\/td\u003e\n\u003ctd\u003eBlack, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eExample Treatment-Time Table for 40 mA-Min\u003c\/h2\u003e\n\u003cp\u003eThe IFU provides examples for delivering a recommended total charge of 40 mA-min.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eRecommended Total Charge\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCurrent\u003c\/th\u003e\n\u003cth align=\"right\"\u003eTime\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e13.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDo not exceed an 80 mAmp·min dosage per single treatment.\u003c\/strong\u003e Current level and treatment time should follow professional direction, device instructions, patient comfort, and applicable prescribing guidance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIonto4™ vs. Wireless Iontophoresis Patches\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIonto4™ Iontophoresis Electrodes\u003c\/th\u003e\n\u003cth\u003eWireless Self-Powered Iontophoresis Patch\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003eExternal FDA-cleared constant-current iontophoresis device\u003c\/td\u003e\n\u003ctd\u003eBuilt-in power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment control\u003c\/td\u003e\n\u003ctd\u003eControlled by the iontophoresis unit\u003c\/td\u003e\n\u003ctd\u003eControlled by the patch design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit contents\u003c\/td\u003e\n\u003ctd\u003eActive electrode, ground electrode, alcohol wipe\u003c\/td\u003e\n\u003ctd\u003ePatch or patch kit, depending on product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize choices\u003c\/td\u003e\n\u003ctd\u003eSmall, Medium, Large, Butterfly\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eClinics using constant-current iontophoresis devices\u003c\/td\u003e\n\u003ctd\u003eClinics wanting self-powered wearable patch workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup requirement\u003c\/td\u003e\n\u003ctd\u003eRequires polarity and lead-wire connection\u003c\/td\u003e\n\u003ctd\u003eUsually no external leads or controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIonto4™ vs. Reusable Electrotherapy Electrodes\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eIonto4™ Iontophoresis Electrodes\u003c\/th\u003e\n\u003cth\u003eStandard Reusable TENS\/NMES Electrodes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary purpose\u003c\/td\u003e\n\u003ctd\u003eIontophoretic drug delivery\u003c\/td\u003e\n\u003ctd\u003eElectrical stimulation contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-use\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eUsually reusable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrug matrix\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround electrode included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eUsually not paired as a drug\/ground kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol wipe included\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eProduct-dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication delivery\u003c\/td\u003e\n\u003ctd\u003eDesigned for soluble salts or other medications under clinical direction\u003c\/td\u003e\n\u003ctd\u003eNot designed for drug delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice type\u003c\/td\u003e\n\u003ctd\u003eConstant-current iontophoresis device\u003c\/td\u003e\n\u003ctd\u003eTENS, NMES, EMS, or other electrotherapy device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement decision\u003c\/td\u003e\n\u003ctd\u003eChoose by matrix volume and placement\u003c\/td\u003e\n\u003ctd\u003eChoose by size, shape, gel, and connector compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndications Summary\u003c\/h2\u003e\n\u003cp\u003eIonto4™ Iontophoresis Electrodes are indicated for the administration of soluble salts or other medications into the body for medical purposes as an alternative to hypodermic injection.\u003c\/p\u003e\n\u003cp\u003eUse should follow:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePrescriber direction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedication labeling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDevice instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIonto4™ IFU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacility protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatient screening\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProfessional clinical judgment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eContraindications and Use Restrictions\u003c\/h2\u003e\n\u003cp\u003eIontophoresis is contraindicated for patients with:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eContraindication \/ Restriction\u003c\/th\u003e\n\u003cth\u003eExplanation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardiac pacemakers or electrically sensitive implanted devices\u003c\/td\u003e\n\u003ctd\u003eElectrical current may interfere with sensitive devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnown sensitivity to the drug being administered\u003c\/td\u003e\n\u003ctd\u003eDrug allergy or sensitivity must be considered before use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnown adverse reactions to electrical current\u003c\/td\u003e\n\u003ctd\u003eTreatment may not be appropriate for patients with prior adverse responses.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamaged skin or recent scar tissue\u003c\/td\u003e\n\u003ctd\u003eDo not place electrodes over compromised skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporal or orbital regions\u003c\/td\u003e\n\u003ctd\u003eDo not use across the temporal regions or for treatment of the eye region\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Warnings and Precautions\u003c\/h2\u003e\n\u003cp\u003eIonto4™ electrodes should be used only according to the IFU, device manual, medication labeling, and professional guidance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWarning \/ Precaution\u003c\/th\u003e\n\u003cth\u003ePractical Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse only with FDA-cleared constant-current iontophoresis devices\u003c\/td\u003e\n\u003ctd\u003eDo not use with incompatible devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not exceed 80 mAmp.min per single treatment\u003c\/td\u003e\n\u003ctd\u003eFollow dosage limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-use only\u003c\/td\u003e\n\u003ctd\u003eDo not reuse after treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not apply over damaged skin\u003c\/td\u003e\n\u003ctd\u003eAvoid open wounds, pimples, recent scar tissue, or recently healed tissue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvoid hair follicles and moles\u003c\/td\u003e\n\u003ctd\u003eDo not shave the application area immediately before use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not use over, weight-bearing areas\u003c\/td\u003e\n\u003ctd\u003eAvoid pressure that can affect the patch during treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not bind, tape, or compress the electrode\u003c\/td\u003e\n\u003ctd\u003ePressure can affect performance and skin response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not get electrodes wet\u003c\/td\u003e\n\u003ctd\u003eMoisture may cause electrodes to short\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not allow metal contact\u003c\/td\u003e\n\u003ctd\u003eRemove jewelry and keep metals away from electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not remove electrodes before terminating current\u003c\/td\u003e\n\u003ctd\u003eTurn off the current source before removing electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo not use drug suspensions\u003c\/td\u003e\n\u003ctd\u003eFollow medication and solution requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvoid gels, creams, or oils before treatment\u003c\/td\u003e\n\u003ctd\u003eDo not apply to areas treated with gels, creams, or oils within the last 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatch for irritation or burns\u003c\/td\u003e\n\u003ctd\u003eAdvise patients to report burning or discomfort immediately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eStorage and Handling\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage \/ Handling Item\u003c\/th\u003e\n\u003cth\u003eGuidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse type\u003c\/td\u003e\n\u003ctd\u003eSingle-use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eNon-sterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eStore at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat exposure\u003c\/td\u003e\n\u003ctd\u003eDo not expose to temperatures above 125°F \/ 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReuse\u003c\/td\u003e\n\u003ctd\u003eDo not reuse after a single treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eDiscard after treatment according to facility policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Ionto4™ Iontophoretic Delivery Kit is a dependable single-use electrode system for professional iontophoresis treatments. Each box includes 12 individually packaged kits, and each kit includes one active drug electrode, one return electrode, and one alcohol prep pad.\u003c\/p\u003e\n\u003cp\u003eThe active electrode is designed for optimized buffering and solution absorption, while the large ground electrode is designed to reduce sensation and improve patient comfort. The carbon-Ag\/AgCl technology supports precise buffering, and the large adhesive surface area helps keep electrodes in place during treatment.\u003c\/p\u003e\n\u003cp\u003eWith four size options—Small Square, Medium Square, Large Square, and Butterfly—Ionto4™ gives clinicians flexibility when matching fill volume and electrode shape to the treatment site.\u003c\/p\u003e\n\u003cp\u003eOrder from Balego to source Ionto4™ iontophoresis electrodes, iontophoresis supplies, electrotherapy electrodes, contact media, and professional rehabilitation products from one trusted supplier.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat to Order With Ionto4™\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eRelated Product Type\u003c\/th\u003e\n\u003cth\u003eWhy It May Be Needed\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDA-cleared constant-current iontophoresis device\u003c\/td\u003e\n\u003ctd\u003eRequired to operate Ionto4™ electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication or soluble salt solution\u003c\/td\u003e\n\u003ctd\u003eRequired for the prescribed treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe or filling accessory\u003c\/td\u003e\n\u003ctd\u003eUsed to hydrate the drug delivery matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGloves and clinical prep supplies\u003c\/td\u003e\n\u003ctd\u003eSupports clean treatment setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin prep supplies\u003c\/td\u003e\n\u003ctd\u003eAn alcohol prep pad is included, but facilities may need additional supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode disposal supplies\u003c\/td\u003e\n\u003ctd\u003eSupports single-use clinical disposal workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIontophoresis documentation forms\u003c\/td\u003e\n\u003ctd\u003eHelps record dose, current, time, site, and patient response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eBuyer’s Guide\u003c\/h2\u003e\n\u003ch3\u003eChoose Ionto4™ if\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYour clinic already uses FDA-cleared constant-current iontophoresis equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need single-use drug-delivery electrode kits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want active and ground electrodes packaged together.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou prefer a kit that includes an alcohol prep pad.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need multiple size and fill-volume options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want carbon-Ag\/AgCl iontophoresis electrode technology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want electrodes not made with natural rubber latex.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYour facility prefers disposable treatment kits for consistent workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConsider a self-powered patch instead if\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a wireless patch with built-in power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou do not want to connect lead wires to an external iontophoresis unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYour workflow is based around pre-designed mA-min patch delivery times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want patients to leave the clinic with a self-powered patch in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy Ionto4™ from Balego?\u003c\/h2\u003e\n\u003cp\u003eWhen you buy Ionto4™ iontophoresis electrodes from Balego, you can source professional iontophoresis products and clinical therapy supplies from a supplier focused on rehabilitation, electrotherapy, contact media, electrodes, and patient care products.\u003c\/p\u003e\n\u003cp\u003eBalego offers:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFree shipping across the USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBest-price guarantee\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProfessional therapy product selection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIontophoresis product options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrotherapy and rehabilitation supply categories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct support through our contact page\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is Ionto4™?\u003c\/h3\u003e\n\u003cp\u003eIonto4™ is a single-use iontophoresis electrode treatment kit used with FDA-cleared constant-current iontophoresis devices for professional drug-delivery iontophoresis workflows.\u003c\/p\u003e\n\u003ch3\u003eWhat comes in each Ionto4™ treatment pouch?\u003c\/h3\u003e\n\u003cp\u003eEach pouch contains one active drug electrode, one ground or return electrode, and one alcohol prep pad.\u003c\/p\u003e\n\u003ch3\u003eHow many treatment kits come in a box?\u003c\/h3\u003e\n\u003cp\u003eEach box includes 12 individual treatment kits.\u003c\/p\u003e\n\u003ch3\u003eWhat sizes are available?\u003c\/h3\u003e\n\u003cp\u003eIonto4™ is available in Small Square 1.5cc, Medium Square 2.5cc, Large Square 4.0cc, and Butterfly 2.0cc options.\u003c\/p\u003e\n\u003ch3\u003eWhich SKU is the Small Square Ionto4™ electrode?\u003c\/h3\u003e\n\u003cp\u003eSmall Square is SKU NC89375.\u003c\/p\u003e\n\u003ch3\u003eWhich SKU is the Medium Square Ionto4™ electrode?\u003c\/h3\u003e\n\u003cp\u003eMedium Square is SKU NC89376.\u003c\/p\u003e\n\u003ch3\u003eWhich SKU is the Large Square Ionto4™ electrode?\u003c\/h3\u003e\n\u003cp\u003eLarge Square is SKU NC89377.\u003c\/p\u003e\n\u003ch3\u003eWhich SKU is the Butterfly Ionto4™ electrode?\u003c\/h3\u003e\n\u003cp\u003eButterfly is SKU NC89378.\u003c\/p\u003e\n\u003ch3\u003eIs Ionto4™ made with natural rubber latex?\u003c\/h3\u003e\n\u003cp\u003eNo. Ionto4™ electrodes are not made with natural rubber latex.\u003c\/p\u003e\n\u003ch3\u003eIs Ionto4™ reusable?\u003c\/h3\u003e\n\u003cp\u003eNo. Ionto4™ electrodes are single-use only and should be discarded after treatment.\u003c\/p\u003e\n\u003ch3\u003eDoes Ionto4™ include medication?\u003c\/h3\u003e\n\u003cp\u003eNo. Medication or solution is not included. Medication selection and use should follow prescriber direction, drug labeling, facility protocol, and the IFU.\u003c\/p\u003e\n\u003ch3\u003eWhat device is required?\u003c\/h3\u003e\n\u003cp\u003eIonto4™ electrodes must be used with an FDA-cleared, constant-current iontophoresis device.\u003c\/p\u003e\n\u003ch3\u003eWhat is the maximum dosage per treatment?\u003c\/h3\u003e\n\u003cp\u003eDo not exceed an 80 mAmp·min dosage per single treatment.\u003c\/p\u003e\n\u003ch3\u003eHow far away should the ground electrode be placed?\u003c\/h3\u003e\n\u003cp\u003eThe IFU instructs users to place the ground electrode on a major muscle 4\"–6\" away from the active electrode.\u003c\/p\u003e\n\u003ch3\u003eHow do I connect the polarity?\u003c\/h3\u003e\n\u003cp\u003eFor a negative drug or solution, connect the drug electrode to black negative and the ground electrode to red positive. For a positive drug or solution, connect the drug electrode to red and positive and the ground electrode to black and negative.\u003c\/p\u003e\n\u003ch3\u003eDoes Balego offer free shipping?\u003c\/h3\u003e\n\u003cp\u003eYes. Balego lists free shipping across the USA for this product.\u003c\/p\u003e\n\u003ch3\u003eDoes Balego offer a best-price guarantee?\u003c\/h3\u003e\n\u003cp\u003eYes. Balego states that it will match competitor pricing when customers show a competing offer.\u003c\/p\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cem\u003eIonto4 iontophoresis electrodes, Ionto4 iontophoretic delivery kit, iontophoresis electrodes, drug delivery iontophoresis electrode, iontophoresis treatment kit, \u003cspan style=\"font-size: 0.875rem;\"\u003eNC89375, NC89376, NC89377, NC89378, carbon Ag AgCl iontophoresis electrode, silver silver chloride iontophoresis electrode, small iontophoresis electrode, medium iontophoresis electrode, large iontophoresis electrode, butterfly iontophoresis electrode, iontophoresis drug matrix, single-use iontophoresis kit\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"North Coast Medical","offers":[{"title":"Small Square 2.75\" (1.5cc)","offer_id":48730651394303,"sku":"NC89375","price":74.95,"currency_code":"USD","in_stock":true},{"title":"Medium Square 3.25\" (2.5cc)","offer_id":48730651427071,"sku":"NC89376","price":74.95,"currency_code":"USD","in_stock":true},{"title":"Large Square\t3.5\"\t(4.0cc)","offer_id":48730651459839,"sku":"NC89377","price":74.95,"currency_code":"USD","in_stock":true},{"title":"Butterfly\tButterfly\t3.75\" x 3.3\"\t(2.0cc)","offer_id":48730651492607,"sku":"NC89378","price":74.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/2025_04_18_15_43_59__10_nc89375_7047_kit_w_25.jpg?v=1762551707","url":"https:\/\/balego-stores.myshopify.com\/products\/ionto4-iontophoresis-electrodes","provider":"Balego","version":"1.0","type":"link"}