{"product_id":"kendall-medi-trace-200-series","title":"Kendall Medi-Trace 200 Series Foam ECG Monitoring Electrodes","description":"\u003ch2\u003eKendall™ Medi-Trace™ 200 Series Foam ECG\/EKG Monitoring Electrodes\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKendall Medi-Trace 200 Series\u003c\/strong\u003e is a compact, cost-effective adult ECG\/EKG monitoring electrode designed for lower- to mid-acuity patient-care environments. Its smaller teardrop profile supports convenient placement when space is limited, while the flexible foam substrate conforms to body contours and helps repel fluids.\u003c\/p\u003e\n\u003cp\u003eEach disposable electrode incorporates Cardinal Health’s proprietary conductive adhesive hydrogel. The gel provides adhesion and the conductive skin interface needed for reliable cardiac monitoring, so no separate ECG gel is required. A standard snap connector attaches to compatible patient-monitoring lead wires.\u003c\/p\u003e\n\u003cp\u003eThe 200 Series is commonly selected for general inpatient units, medical-surgical floors, observation units, outpatient monitoring areas, and other routine adult cardiac-monitoring applications. Cardinal Health classifies the family within its Value Choice collection. \u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose adult ECG\/EKG monitoring electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 1.44-inch teardrop profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall footprint for convenient lead placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible foam backing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluid-repellent substrate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProprietary conductive adhesive hydrogel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard snap-style lead connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for clear, reliable ECG tracings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe teardrop shape supports easier handling and removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisposable, single-patient-use format\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-radiolucent construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour pouch and case configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAppropriate for lower- to mid-acuity monitoring environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufactured for the Cardinal Health Kendall portfolio\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 200 Series is a non-radiolucent adult monitoring electrode that has a 1.44-inch footprint, foam substrate, teardrop shape, and conductive adhesive hydrogel. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eMedi-Trace 200 Series details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKendall™ Medi-Trace™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent portfolio\u003c\/td\u003e\n\u003ctd\u003eCardinal Health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003e200 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModels included\u003c\/td\u003e\n\u003ctd\u003e200, 230, 233, and 235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eDisposable ECG\/EKG monitoring electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient category\u003c\/td\u003e\n\u003ctd\u003eAdult\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary application\u003c\/td\u003e\n\u003ctd\u003eGeneral cardiac monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcuity positioning\u003c\/td\u003e\n\u003ctd\u003eLower- to mid-acuity environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eConformable foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid resistance\u003c\/td\u003e\n\u003ctd\u003eFoam substrate helps repel fluids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive interface\u003c\/td\u003e\n\u003ctd\u003eProprietary conductive adhesive hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eTeardrop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-listed size\u003c\/td\u003e\n\u003ctd\u003e1.44 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate metric size\u003c\/td\u003e\n\u003ctd\u003e36.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent counterpart\u003c\/td\u003e\n\u003ctd\u003eKendall 600 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional gel required\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego case options\u003c\/td\u003e\n\u003ctd\u003e600 or 1,000 total electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe four Balego order codes represent packaging variations within the same 200 Series electrode family rather than four different electrode constructions. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003ePackage and case options\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBalego order code\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSeries model\u003c\/th\u003e\n\u003cth align=\"right\"\u003eElectrodes per pouch\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePouches per case\u003c\/th\u003e\n\u003cth align=\"right\"\u003eTotal electrodes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31050522\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eKendall 200\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31078135\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eKendall 230\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e30\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31478368\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eKendall 233\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e200\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e31478376\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eKendall 235\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e120\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecommended Shopify variant names\u003c\/h3\u003e\n\u003cp\u003eReplace abbreviated variant labels with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e31050522 \/ Kendall 200 — 100 per pouch, 10 pouches, 1,000 per case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e31078135 \/ Kendall 230 — 30 per pouch, 20 pouches, 600 per case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e31478368 \/ Kendall 233 — 3 per pouch, 200 pouches, 600 per case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e31478376 \/ Kendall 235 — 5 per pouch, 120 pouches, 600 per case\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes it clear that “3 per pack” and “5 per pack” describe the individually sealed pouch—not the complete case quantity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhich package configuration should a facility choose?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWorkflow\u003c\/th\u003e\n\u003cth\u003eSuggested configuration\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCentralized bulk stocking\u003c\/td\u003e\n\u003ctd\u003eKendall 200, 100\/pouch\u003c\/td\u003e\n\u003ctd\u003eFewer pouches and the lowest packaging frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepartment or cart stocking\u003c\/td\u003e\n\u003ctd\u003eKendall 230, 30\/pouch\u003c\/td\u003e\n\u003ctd\u003eModerate pouch quantity for recurring use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree-lead monitoring kits\u003c\/td\u003e\n\u003ctd\u003eKendall 233, 3\/pouch\u003c\/td\u003e\n\u003ctd\u003ePre-grouped three-electrode quantities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFive-lead monitoring kits\u003c\/td\u003e\n\u003ctd\u003eKendall 235, 5\/pouch\u003c\/td\u003e\n\u003ctd\u003ePre-grouped five-electrode quantities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual procedure packs\u003c\/td\u003e\n\u003ctd\u003eKendall 233 or 235\u003c\/td\u003e\n\u003ctd\u003eHelps reduce counting and repackaging steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-volume hospital supply\u003c\/td\u003e\n\u003ctd\u003eKendall 200\u003c\/td\u003e\n\u003ctd\u003e1,000 electrodes per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe electrode itself remains part of the same 200 Series family. The best configuration depends primarily on lead setup, turnover, storage practices, and open-pouch workflow.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy choose Medi-Trace 200 Series electrodes?\u003c\/h1\u003e\n\u003ch2\u003eCompact footprint\u003c\/h2\u003e\n\u003cp\u003eAt approximately 1.44 inches, the 200 Series is smaller than many general-purpose and stress-monitoring foam electrodes. The reduced footprint can be useful when several leads must be positioned on an adult torso or when available placement space is limited. \u003c\/p\u003e\n\u003ch2\u003eFluid-resistant foam backing\u003c\/h2\u003e\n\u003cp\u003eThe foam substrate helps repel fluids and conforms to ordinary body contours. This makes it practical for routine inpatient and observation workflows where the electrode must remain flat against the skin during general monitoring. \u003c\/p\u003e\n\u003ch2\u003eConductive adhesive hydrogel\u003c\/h2\u003e\n\u003cp\u003eThe integrated hydrogel provides the adhesive and conductive interface between the patient’s skin and ECG monitoring system. Cardinal Health describes it as supporting adhesion and clear, reliable tracings while avoiding messy residue. \u003c\/p\u003e\n\u003ch2\u003eTeardrop profile\u003c\/h2\u003e\n\u003cp\u003eThe tapered portion of the electrode provides clinicians a defined area to grasp when removing the pad from its liner or lifting it from the patient. Handling the foam edge rather than the gel helps limit contamination of the conductive surface.\u003c\/p\u003e\n\u003ch2\u003eMultiple pouch sizes\u003c\/h2\u003e\n\u003cp\u003eThe same electrode is offered in pouches of 3, 5, 30, or 100. This lets facilities align pouch quantity with their monitoring protocols without changing electrode type.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhere are Medi-Trace 200 electrodes commonly used?\u003c\/h1\u003e\n\u003cp\u003eThe 200 Series for lower- to mid-acuity settings. \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical area\u003c\/th\u003e\n\u003cth\u003eTypical role\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral inpatient units\u003c\/td\u003e\n\u003ctd\u003eRoutine adult ECG monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical-surgical floors\u003c\/td\u003e\n\u003ctd\u003eStandard bedside monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObservation units\u003c\/td\u003e\n\u003ctd\u003eShorter-term cardiac observation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutpatient procedure areas\u003c\/td\u003e\n\u003ctd\u003eMonitoring when clinically required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreoperative and postoperative areas\u003c\/td\u003e\n\u003ctd\u003eCompatible routine monitoring workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRehabilitation facilities\u003c\/td\u003e\n\u003ctd\u003eMonitoring under facility protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term care environments\u003c\/td\u003e\n\u003ctd\u003eCompatible provider-directed monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHome monitoring programs\u003c\/td\u003e\n\u003ctd\u003eOnly when supplied and directed by the monitoring provider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese electrodes are not specifically positioned for stress testing, highly active patients, heavy perspiration, neonatal monitoring, or diagnostic resting ECG procedures. Other electrode families may be more appropriate for those applications.\u003c\/p\u003e\n\u003cp\u003eBrowse our complete \u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003emonitoring EKG\/ECG electrode collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eECG monitoring electrodes are not stimulation pads\u003c\/h1\u003e\n\u003cp\u003eThe Medi-Trace 200 Series is designed to \u003cstrong\u003ereceive the heart’s electrical signal\u003c\/strong\u003e and transfer it to compatible monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eIt is not designed to deliver therapeutic current.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode category\u003c\/th\u003e\n\u003cth\u003ePrimary purpose\u003c\/th\u003e\n\u003cth\u003eTypical connector\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG monitoring electrode\u003c\/td\u003e\n\u003ctd\u003eRecords cardiac electrical activity over time\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eMedi-Trace 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResting diagnostic electrode\u003c\/td\u003e\n\u003ctd\u003eShort diagnostic ECG acquisition\u003c\/td\u003e\n\u003ctd\u003eTab or clip\u003c\/td\u003e\n\u003ctd\u003eKendall 5400 or 5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStress\/Holter electrode\u003c\/td\u003e\n\u003ctd\u003eMonitoring with greater movement or perspiration\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eMedi-Trace 530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTENS\/NMES electrode\u003c\/td\u003e\n\u003ctd\u003eDelivers electrical stimulation\u003c\/td\u003e\n\u003ctd\u003ePin, snap, or proprietary\u003c\/td\u003e\n\u003ctd\u003eBalego reusable TENS pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation electrode\u003c\/td\u003e\n\u003ctd\u003eDefibrillation, cardioversion, or pacing\u003c\/td\u003e\n\u003ctd\u003eDevice-specific cable\u003c\/td\u003e\n\u003ctd\u003eMultifunction defibrillation pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrosurgical return electrode\u003c\/td\u003e\n\u003ctd\u003eReturns electrosurgical current\u003c\/td\u003e\n\u003ctd\u003eDevice-specific\u003c\/td\u003e\n\u003ctd\u003eGrounding or return pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not use the Medi-Trace 200 Series for TENS, NMES, EMS, FES, iontophoresis, defibrillation, pacing, or electrosurgical return applications.\u003c\/p\u003e\n\u003cp\u003eCustomers looking for stimulation pads should visit our \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct comparison\u003c\/h1\u003e\n\u003ch2\u003eMedi-Trace 200 vs. Medi-Trace 450 vs. Medi-Trace 530\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/kendall-medi-trace-200-series\"\u003eMedi-Trace 200 Series\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/kendall-medi-trace-450\"\u003eMedi-Trace 450 Series\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eMedi-Trace 530 Series\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary positioning\u003c\/td\u003e\n\u003ctd\u003eEconomical general adult monitoring\u003c\/td\u003e\n\u003ctd\u003eMultipurpose housewide adult monitoring\u003c\/td\u003e\n\u003ctd\u003eChallenging, active, or diaphoretic monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcuity focus\u003c\/td\u003e\n\u003ctd\u003eLower-to-mid acuity\u003c\/td\u003e\n\u003ctd\u003eBroad general-purpose use\u003c\/td\u003e\n\u003ctd\u003eStress, Holter, activity, and higher-demand environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eSmall teardrop\u003c\/td\u003e\n\u003ctd\u003eRectangle\u003c\/td\u003e\n\u003ctd\u003eLarger teardrop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e1.44 in.\u003c\/td\u003e\n\u003ctd\u003e1.438 × 1.656 in.\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eFoam\u003c\/td\u003e\n\u003ctd\u003eThin foam\u003c\/td\u003e\n\u003ctd\u003eFoam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive adhesive hydrogel\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesion positioning\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose\u003c\/td\u003e\n\u003ctd\u003eMultipurpose\u003c\/td\u003e\n\u003ctd\u003eMore aggressive for difficult environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePouch options at Balego\u003c\/td\u003e\n\u003ctd\u003e3, 5, 30, or 100\u003c\/td\u003e\n\u003ctd\u003e3, 5, or 50\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal case quantity\u003c\/td\u003e\n\u003ctd\u003e600 or 1,000\u003c\/td\u003e\n\u003ctd\u003e600 or 1,000\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eCompact, cost-conscious routine monitoring\u003c\/td\u003e\n\u003ctd\u003eStandardized housewide monitoring\u003c\/td\u003e\n\u003ctd\u003eMotion, perspiration, stress, and Holter workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 200 Series for lower- to mid-acuity floors and the 450 Series for multipurpose adult monitoring. The 530 Series is commonly selected when stronger adhesion is needed for stress testing, Holter monitoring, active patients, or diaphoretic conditions. \u003c\/p\u003e\n\u003ch3\u003eChoose the Medi-Trace 200 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA compact adult electrode is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine lower- or mid-acuity monitoring is the main application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-conscious standardization is a priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePre-grouped 3- or 5-electrode pouches support the workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe patient is expected to have normal perspiration and movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the Medi-Trace 450 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA broader, multipurpose housewide electrode is desired.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA rectangular pad and larger gel-contact area are preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA facility wants 3-, 5-, or 50-electrode pouches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard general monitoring is the primary need.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the Medi-Trace 530 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePatients may move or perspire heavily.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStress testing or Holter monitoring is performed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMore aggressive adhesion is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA larger foam electrode is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eMedi-Trace 200 vs. Kendall 600 radiolucent electrodes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eMedi-Trace 200\u003c\/th\u003e\n\u003cth\u003eKendall 600 Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral design\u003c\/td\u003e\n\u003ctd\u003eCompact foam ECG monitoring electrode\u003c\/td\u003e\n\u003ctd\u003eRadiolucent version of the compact foam design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive hydrogel\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImaging workflow\u003c\/td\u003e\n\u003ctd\u003eFollow imaging protocol; removal may be required\u003c\/td\u003e\n\u003ctd\u003eDesigned for workflows requiring radiolucency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eRoutine monitoring without a radiolucency requirement\u003c\/td\u003e\n\u003ctd\u003eMonitoring when imaging compatibility is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe Kendall 600 Series is the radiolucent version of the 200 Series. \u003c\/p\u003e\n\u003cp\u003eDo not assume that a non-radiolucent electrode may remain on a patient during imaging. Follow the imaging department’s protocol and the equipment manufacturer’s instructions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedi-Trace 200 vs. resting diagnostic tab electrodes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eMedi-Trace 200\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003eKendall 5400 Resting Tabs\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003eBalego 5500 Diagnostic Tabs\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd\u003eOngoing monitoring\u003c\/td\u003e\n\u003ctd\u003eResting diagnostic ECG\u003c\/td\u003e\n\u003ctd\u003eResting diagnostic ECG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eTab\/grabber\u003c\/td\u003e\n\u003ctd\u003eTab\/grabber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eFoam\u003c\/td\u003e\n\u003ctd\u003eVinyl diagnostic tab\u003c\/td\u003e\n\u003ctd\u003eRadiolucent diagnostic tab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWear time\u003c\/td\u003e\n\u003ctd\u003eMonitoring workflow\u003c\/td\u003e\n\u003ctd\u003eShort diagnostic recording\u003c\/td\u003e\n\u003ctd\u003eShort diagnostic recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdult use\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePediatric positioning\u003c\/td\u003e\n\u003ctd\u003eNot the primary 200 Series positioning\u003c\/td\u003e\n\u003ctd\u003eCardinal lists 5400 for adult and pediatric use\u003c\/td\u003e\n\u003ctd\u003eFollow product-specific instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eBedside or ambulatory monitoring\u003c\/td\u003e\n\u003ctd\u003eStandard resting ECG acquisition\u003c\/td\u003e\n\u003ctd\u003eHigh-volume radiolucent resting ECG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 400 and 5500 products are diagnostic tab electrodes for resting ECG applications, which are different from continuous or repeated monitoring with the 200 Series. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow to apply Medi-Trace 200 ECG electrodes\u003c\/h1\u003e\n\u003cp\u003eFollow the ECG monitor instructions and the facility’s skin-preparation and lead-placement procedures.\u003c\/p\u003e\n\u003ch2\u003e1. Confirm the correct electrode\u003c\/h2\u003e\n\u003cp\u003eBefore opening the pouch, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCorrect order code and pouch quantity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdult monitoring application\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSnap-lead compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-radiolucent construction is acceptable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe package is within its expiration date\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePouch is sealed and undamaged\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Prepare the skin\u003c\/h2\u003e\n\u003cp\u003eSelect the sites required by the monitoring protocol. The skin should generally be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eClean\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFree of lotion and body oil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFree of excessive perspiration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrepared according to facility policy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExcessive hair may need to be clipped—not shaved—when facility procedures require improved electrode contact.\u003c\/p\u003e\n\u003ch2\u003e3. Connect the monitoring lead\u003c\/h2\u003e\n\u003cp\u003eThe lead may be snapped to the electrode before or after application, depending on the facility’s workflow. Confirm that the snap is fully engaged.\u003c\/p\u003e\n\u003cp\u003eAvoid twisting the snap after the pad has been applied, as this action can place unnecessary tension on the foam and skin.\u003c\/p\u003e\n\u003ch2\u003e4. Remove the pad from its liner\u003c\/h2\u003e\n\u003cp\u003eHold the electrode by the foam edge or tapered portion. Avoid touching the conductive hydrogel.\u003c\/p\u003e\n\u003ch2\u003e5. Apply it evenly\u003c\/h2\u003e\n\u003cp\u003ePlace the electrode at the selected monitoring site and press from the center outward.\u003c\/p\u003e\n\u003cp\u003eMake sure there are no\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFolded edges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir gaps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContaminated gel areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLifted sections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead wires pulling against the pad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e6. Confirm signal quality\u003c\/h2\u003e\n\u003cp\u003eCheck for an appropriate tracing and absence of a lead-off warning.\u003c\/p\u003e\n\u003cp\u003eWhen signal quality is poor, inspect:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSkin preparation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePad adhesion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSnap engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-wire condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatient movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode age or dryness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e7. Remove and discard\u003c\/h2\u003e\n\u003cp\u003eDisconnect the lead according to the monitor instructions. Lift the foam edge and peel the electrode back slowly.\u003c\/p\u003e\n\u003cp\u003eDispose of the used electrode according to facility policy. Do not reapply it to the same patient or use it on another patient.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eStorage and pouch handling\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStore unopened cases according to the temperature and humidity directions printed on the current package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep pouches away from excessive heat, moisture, and direct sunlight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetain unused electrodes in their original pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose the pouch promptly after removing the needed quantity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not use an electrode that is dry, contaminated, damaged, or expired.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not place a removed or used electrode back into the pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow the current label for open-pouch storage life rather than relying on a generalized electrode rule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Medi-Trace 200 hydrogel can remain fresh for up to 45 days after pouch opening, but the current package directions should control storage and disposal decisions. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eTroubleshooting guide\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended action\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-off warning\u003c\/td\u003e\n\u003ctd\u003eSnap is not fully connected\u003c\/td\u003e\n\u003ctd\u003eReconnect the lead securely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe lead-off warning continues\u003c\/td\u003e\n\u003ctd\u003eThe electrode is lifting or dry\u003c\/td\u003e\n\u003ctd\u003ePrepare the skin and apply a fresh electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoisy ECG tracing\u003c\/td\u003e\n\u003ctd\u003ePatient movement\u003c\/td\u003e\n\u003ctd\u003eReduce movement when clinically possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoisy tracing\u003c\/td\u003e\n\u003ctd\u003ePoor skin contact\u003c\/td\u003e\n\u003ctd\u003eReprepare the site and replace the pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent signal\u003c\/td\u003e\n\u003ctd\u003eDamaged or loose lead wire\u003c\/td\u003e\n\u003ctd\u003eInspect or replace the lead according to protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe pad will not adhere\u003c\/td\u003e\n\u003ctd\u003eLotion, oil, sweat, or hair\u003c\/td\u003e\n\u003ctd\u003eSelect and prepare a new site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOne edge lifts\u003c\/td\u003e\n\u003ctd\u003eBody contour or lead-wire tension\u003c\/td\u003e\n\u003ctd\u003eReroute the wire and use a fresh electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe gel looks dry\u003c\/td\u003e\n\u003ctd\u003ePouch storage or age issue\u003c\/td\u003e\n\u003ctd\u003eDiscard the electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin becomes irritated\u003c\/td\u003e\n\u003ctd\u003eAdhesive sensitivity, moisture, or prolonged contact\u003c\/td\u003e\n\u003ctd\u003eRemove and assess according to clinical policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAn electrode appears on an image\u003c\/td\u003e\n\u003ctd\u003eThe product is non-radioluscent.\u003c\/td\u003e\n\u003ctd\u003eFollow imaging protocol or use a radiolucent electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracing remains poor with fresh pads\u003c\/td\u003e\n\u003ctd\u003eMonitor, cable, placement, or patient issue\u003c\/td\u003e\n\u003ctd\u003eFollow the monitor manufacturer’s troubleshooting process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe snap detaches during movement\u003c\/td\u003e\n\u003ctd\u003eLead tension or incomplete snap engagement\u003c\/td\u003e\n\u003ctd\u003eReconnect and support the lead wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeveral electrodes fail from one pouch\u003c\/td\u003e\n\u003ctd\u003eThe pouch may have been improperly stored\u003c\/td\u003e\n\u003ctd\u003eQuarantine the pouch and inspect lot and expiration information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat are Kendall Medi-Trace 200 Series electrodes?\u003c\/h2\u003e\n\u003cp\u003eThey are disposable adult foam ECG\/EKG monitoring electrodes designed for routine lower- to mid-acuity cardiac monitoring. The family includes models 200, 230, 233, and 235, which differ primarily by pouch and case quantity. \u003c\/p\u003e\n\u003ch2\u003eWhat size are they?\u003c\/h2\u003e\n\u003cp\u003eThe 200 Series is 1.44 inches, approximately 36.6 mm. The teardrop profile is compact for convenient lead placement. \u003c\/p\u003e\n\u003ch2\u003eWhat connector do they use?\u003c\/h2\u003e\n\u003cp\u003eThey use a standard snap connection for compatible ECG monitoring lead wires.\u003c\/p\u003e\n\u003ch2\u003eAre the four models different sizes?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health groups all four order codes under the 200 Series construction. Their primary difference is package configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e200: 100 per pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e230: 30 per pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e233: 3 per pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e235: 5 per pouch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow many electrodes are in a case?\u003c\/h2\u003e\n\u003cp\u003eDepending on the selected order code, the case contains either 600 or 1,000 electrodes.\u003c\/p\u003e\n\u003ch2\u003eAre these adult or pediatric electrodes?\u003c\/h2\u003e\n\u003cp\u003eThe 200 Series as a general adult monitoring electrode. Select a pediatric or neonatal product when required by the patient and monitoring protocol. \u003c\/p\u003e\n\u003ch2\u003eAre they radiolucent?\u003c\/h2\u003e\n\u003cp\u003eNo. The Kendall 200 Series is non-radiolucent. Cardinal Health identifies the Kendall 600 Series as the radiolucent counterpart. \u003c\/p\u003e\n\u003ch2\u003eAre they appropriate for stress testing?\u003c\/h2\u003e\n\u003cp\u003eThey are positioned for routine lower- to mid-acuity monitoring. The \u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eMedi-Trace 530\u003c\/a\u003e is more specifically positioned for stress, Holter, active, and diaphoretic applications.\u003c\/p\u003e\n\u003ch2\u003eCan they be used for a resting 12-lead ECG?\u003c\/h2\u003e\n\u003cp\u003eThey are snap-style monitoring electrodes. Resting ECG systems commonly use tab-style diagnostic electrodes such as the \u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003eKendall 5400\u003c\/a\u003e or \u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003eBalego 5500\u003c\/a\u003e. Use the electrode style specified by the ECG equipment and facility protocol.\u003c\/p\u003e\n\u003ch2\u003eCan Medi-Trace 200 electrodes be reused?\u003c\/h2\u003e\n\u003cp\u003eNo. They are disposable monitoring electrodes. Remove and discard them according to facility procedures.\u003c\/p\u003e\n\u003ch2\u003eDo they need separate conductive gel?\u003c\/h2\u003e\n\u003cp\u003eNo. Conductive adhesive hydrogel is incorporated into the electrode. Additional gel is not normally used. \u003c\/p\u003e\n\u003ch2\u003eCan they be used for TENS or NMES?\u003c\/h2\u003e\n\u003cp\u003eNo. TENS and NMES pads deliver therapeutic stimulation current. Medi-Trace 200 electrodes are designed to acquire cardiac signals for ECG monitoring.\u003c\/p\u003e\n\u003cp\u003eBrowse compatible stimulation products in our \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan they be used for defibrillation or pacing?\u003c\/h2\u003e\n\u003cp\u003eNo. They are routine ECG monitoring electrodes, not multifunction defibrillation or pacing pads.\u003c\/p\u003e\n\u003ch2\u003eAre they hypoallergenic?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health does not describe the 200 Series as hypoallergenic on its current product page. Avoid that claim unless product-specific documentation is available.\u003c\/p\u003e\n\u003ch2\u003eWhy does the product have a teardrop shape?\u003c\/h2\u003e\n\u003cp\u003eThe tapered section provides a convenient area for handling and removal while maintaining a compact conductive contact area. Cardinal Health specifically identifies the shape as facilitating removal from both the liner and the patient. \u003c\/p\u003e\n\u003ch2\u003eWhy choose a three- or five-electrode pouch?\u003c\/h2\u003e\n\u003cp\u003eSmall pouches can align with common three- or five-lead monitoring setups, reduce counting, and keep unused electrodes sealed until another patient or procedure.\u003c\/p\u003e\n\u003ch2\u003eWhy choose the 100-electrode pouch?\u003c\/h2\u003e\n\u003cp\u003eIt may be more efficient for high-volume departments with centralized stocking and frequent electrode use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003eMonitoring EKG\/ECG Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/kendall-medi-trace-450\"\u003eKendall Medi-Trace 450 Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eKendall Medi-Trace 530 Foam Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003eKendall 5400 Resting Tab Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003eBalego 5500 Diagnostic Tab Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\"\u003eEEG and ECG Diagnostic Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/ten20-vs-nuprep-when-to-use-each-product\"\u003eTen20 vs. NuPrep: When to Use Each\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/price-guarantee\"\u003eBest Price Guarantee\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cardinal Health","offers":[{"title":"31078135 (30\/pack - 600\/case)","offer_id":48859484094719,"sku":null,"price":149.95,"currency_code":"USD","in_stock":true},{"title":"31478376 (5\/pack - 600\/case)","offer_id":48859537441023,"sku":null,"price":155.95,"currency_code":"USD","in_stock":true},{"title":"31478368 (3\/pack - 600\/case)","offer_id":48859484127487,"sku":null,"price":169.95,"currency_code":"USD","in_stock":true},{"title":"31050522 (100\/pack - 1000\/case)","offer_id":48859484061951,"sku":null,"price":195.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Kendall_Medi-Trace_200SeriesFoamElectrodes.png?v=1784577024","url":"https:\/\/balego-stores.myshopify.com\/products\/kendall-medi-trace-200-series","provider":"Balego","version":"1.0","type":"link"}