{"product_id":"kendall-medi-trace-450","title":"Kendall Medi-Trace 450 Foam ECG Monitoring Electrodes","description":"\u003ch2\u003eKendall™ Medi-Trace™ 450 Foam ECG\/EKG Monitoring Electrodes\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKendall Medi-Trace 450 Series\u003c\/strong\u003e is a general-purpose adult ECG\/EKG monitoring electrode that provides reliable adhesion, flexible patient contact, and clear cardiac-monitoring tracings in hospital and clinical workflows.\u003c\/p\u003e\n\u003cp\u003eEach disposable electrode has a thin, flexible foam backing and a proprietary conductive adhesive hydrogel. The foam backing resists fluids and fits ordinary body contours, while the integrated hydrogel helps keep the electrode on the patient and maintain the electrode-to-skin interface needed for ECG monitoring.\u003c\/p\u003e\n\u003cp\u003eA standard snap connector provides a secure connection to compatible ECG lead wires. A courtesy lift tab along one edge makes the pad easier to handle, apply, anchor, and remove without pulling directly on the monitoring snap. Cardinal Health identifies the 450 Series as a multipurpose adult electrode for general hospital monitoring, including medical-surgical floors, orthopedic units, observation areas, step-down units, and oncology settings. \u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdult disposable ECG\/EKG monitoring electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose hospital and clinical use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThin, flexible foam substrate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluid-resistant backing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProprietary conductive adhesive hydrogel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge hydrogel contact surface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard snap-style monitor connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCourtesy lift tab for handling and removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRectangular profile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-radiolucent construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot made with natural rubber latex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot made with DEHP or mercury\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable in 3-, 5-, or 50-electrode pouch formats\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBulk case configurations for healthcare facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick product specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eKendall Medi-Trace 450: details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eKendall™ Medi-Trace™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent portfolio\u003c\/td\u003e\n\u003ctd\u003eCardinal Health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct family\u003c\/td\u003e\n\u003ctd\u003e450 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eECG\/EKG monitoring electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended patient\u003c\/td\u003e\n\u003ctd\u003eAdult\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse type\u003c\/td\u003e\n\u003ctd\u003eDisposable, single-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring category\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose cardiac monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eThin foam substrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eConductive adhesive hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eSnap connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eRectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-listed size\u003c\/td\u003e\n\u003ctd\u003e1.438 × 1.656 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate metric size\u003c\/td\u003e\n\u003ctd\u003e36.5 × 42.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluid resistance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLift tab\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural rubber latex\u003c\/td\u003e\n\u003ctd\u003eNot made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDEHP\u003c\/td\u003e\n\u003ctd\u003eNot made with DEHP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMercury\u003c\/td\u003e\n\u003ctd\u003eNot made with mercury\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeparate gel required\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego category\u003c\/td\u003e\n\u003ctd\u003eMonitoring EKG\/ECG Electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe rectangular dimensions are 1.438 × 1.656 inches and specifically describe the 450 Series as non-radiolucent. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003ePackage and case options\u003c\/h1\u003e\n\u003cp\u003eThe product formulation is the same across the three order codes; the principal difference is the number of electrodes sealed in each pouch. The smaller pouch counts may simplify 3- or 5-electrode workflow preparation, while the 50-count pouch supports centralized bulk use. \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrder code\u003c\/th\u003e\n\u003cth align=\"right\"\u003eElectrodes per pouch\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePouches per case\u003c\/th\u003e\n\u003cth align=\"right\"\u003eTotal electrodes\u003c\/th\u003e\n\u003cth\u003ePractical stocking format\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e22450\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e50\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1,000\u003c\/td\u003e\n\u003ctd\u003eBulk hospital and department stocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e22453-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e200\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e600\u003c\/td\u003e\n\u003ctd\u003eIndividually grouped 3-electrode sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e22455-\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e120\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e600\u003c\/td\u003e\n\u003ctd\u003eIndividually grouped 5-electrode sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRecommended Shopify variant names\u003c\/h3\u003e\n\u003cp\u003eReplace the current abbreviated labels with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22450 — 50\/pouch, 20 pouches\/case, 1,000 electrodes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22453- — 3\/pouch, 200 pouches\/case, 600 electrodes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e22455- — 5\/pouch, 120 pouches\/case, 600 electrodes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature makes the purchasing quantity visible before a customer selects a variation and reduces the risk of confusing pouch quantity with total case quantity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy choose Medi-Trace 450 monitoring electrodes?\u003c\/h1\u003e\n\u003ch2\u003eThin, conformable foam\u003c\/h2\u003e\n\u003cp\u003eThe low-profile foam substrate is flexible enough to follow patient contours while providing a stable base for the hydrogel and snap connection. Cardinal Health describes the foam as fluid-resistant and designed to maintain adhesion during general monitoring use. \u003c\/p\u003e\n\u003ch2\u003eConductive adhesive hydrogel\u003c\/h2\u003e\n\u003cp\u003eThe hydrogel serves two functions:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eIt adheres the electrode to the patient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIt creates the conductive interface needed to transfer cardiac electrical signals to the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eBecause the gel is incorporated into the electrode, no separate ECG gel is normally required. Cardinal Health states that the proprietary hydrogel supports adhesion and clear, reliable tracings while minimizing messy residue after removal. \u003c\/p\u003e\n\u003ch2\u003eLarge contact surface\u003c\/h2\u003e\n\u003cp\u003eThe broad gel surface provides substantial electrode-to-skin contact relative to the pad’s compact overall dimensions. This helps the electrode remain secure during routine monitoring while still fitting common adult placement sites. \u003c\/p\u003e\n\u003ch2\u003eCourtesy lift tab\u003c\/h2\u003e\n\u003cp\u003eThe lift tab provides clinicians with a place to hold when\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRemoving the electrode from its liner\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePositioning it on the patient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressing or anchoring an edge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoving it after monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHandling the lift tab instead of the hydrogel helps protect the conductive surface from oils, gloves, and other contamination. \u003c\/p\u003e\n\u003ch2\u003eMultiple pouch configurations\u003c\/h2\u003e\n\u003cp\u003eThe same 450 Series electrode can be ordered in cases built around 3-, 5-, or 50-electrode pouches. This allows a facility to choose between procedural convenience and bulk departmental stocking without changing electrode construction. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhere are Kendall Medi-Trace 450 electrodes commonly used?\u003c\/h1\u003e\n\u003cp\u003eThe 450 Series is for housewide, general-purpose adult monitoring. \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical setting\u003c\/th\u003e\n\u003cth\u003eHow the electrode fits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedical-surgical floors\u003c\/td\u003e\n\u003ctd\u003eGeneral adult bedside ECG monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObservation units\u003c\/td\u003e\n\u003ctd\u003eShorter-term monitoring and evaluation workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep-down units\u003c\/td\u003e\n\u003ctd\u003eRoutine cardiac monitoring outside intensive care\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrthopedic floors\u003c\/td\u003e\n\u003ctd\u003eMonitoring patients before or after procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOncology units\u003c\/td\u003e\n\u003ctd\u003eGeneral ECG monitoring when clinically indicated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency and procedural areas\u003c\/td\u003e\n\u003ctd\u003eCompatible routine monitoring applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutpatient facilities\u003c\/td\u003e\n\u003ctd\u003eAdult monitoring with compatible snap-lead equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHome-health monitoring\u003c\/td\u003e\n\u003ctd\u003eOnly when supplied and directed by the monitoring provider\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 450 Series should be selected according to the monitoring system’s instructions, facility protocol, expected wear conditions, patient skin, imaging requirements, and lead-wire compatibility.\u003c\/p\u003e\n\u003cp\u003eBrowse our complete \u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003emonitoring EKG\/ECG electrode collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eECG monitoring electrodes vs. diagnostic and stimulation electrodes\u003c\/h1\u003e\n\u003cp\u003eNot every adhesive electrode performs the same function.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode category\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003cth\u003eTypical connection\u003c\/th\u003e\n\u003cth align=\"right\"\u003eReusable?\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG monitoring electrode\u003c\/td\u003e\n\u003ctd\u003eOngoing acquisition of cardiac electrical signals\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eMedi-Trace 450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic resting ECG electrode\u003c\/td\u003e\n\u003ctd\u003eShort resting diagnostic recording\u003c\/td\u003e\n\u003ctd\u003eTab or clip\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eKendall 5400 or 5500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStress\/Holter electrode\u003c\/td\u003e\n\u003ctd\u003eHigher-motion, diaphoretic, or extended monitoring\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eMedi-Trace 530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTENS\/NMES stimulating electrode\u003c\/td\u003e\n\u003ctd\u003eDelivers current from a stimulation device into the body\u003c\/td\u003e\n\u003ctd\u003ePin, pigtail, snap, or proprietary\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eOften\u003c\/td\u003e\n\u003ctd\u003eBalego reusable stimulation pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation electrode\u003c\/td\u003e\n\u003ctd\u003eDelivers high-energy therapy or supports pacing\u003c\/td\u003e\n\u003ctd\u003eProprietary cable connection\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDefibrillation pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding or return electrode\u003c\/td\u003e\n\u003ctd\u003eProvides a return path for a specified device\u003c\/td\u003e\n\u003ctd\u003eDevice-specific\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eVaries\u003c\/td\u003e\n\u003ctd\u003eMedical grounding pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eDo not use Medi-Trace 450 electrodes as TENS, NMES, EMS, FES, iontophoresis, defibrillation, or electrosurgical return electrodes.\u003c\/strong\u003e They are designed to receive and transmit cardiac signals to compatible monitoring equipment—not to deliver therapeutic stimulation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedi-Trace 450 product comparison\u003c\/h1\u003e\n\u003ch2\u003eKendall 450 vs. Kendall 530 vs. 5500 diagnostic tabs\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/kendall-medi-trace-450\"\u003eMedi-Trace 450\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eMedi-Trace 530 Foam Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003e5500 Diagnostic Tab Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary application\u003c\/td\u003e\n\u003ctd\u003eGeneral adult monitoring\u003c\/td\u003e\n\u003ctd\u003eStress, Holter, active, or diaphoretic monitoring\u003c\/td\u003e\n\u003ctd\u003eResting diagnostic ECG\/EKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eTab or grabber-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eThin rectangular foam\u003c\/td\u003e\n\u003ctd\u003eLarger teardrop foam\u003c\/td\u003e\n\u003ctd\u003eThin diagnostic tab material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive positioning\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose secure adhesion\u003c\/td\u003e\n\u003ctd\u003eHigher-performance adhesion for challenging monitoring\u003c\/td\u003e\n\u003ctd\u003eHigh-tack diagnostic hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eRectangle\u003c\/td\u003e\n\u003ctd\u003eTeardrop\u003c\/td\u003e\n\u003ctd\u003eTab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate size\u003c\/td\u003e\n\u003ctd\u003e1.438 × 1.656 in.\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.75-in. diameter\u003c\/td\u003e\n\u003ctd\u003eDiagnostic tab format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes, on Balego’s listed 5500 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack options\u003c\/td\u003e\n\u003ctd\u003e3, 5, or 50 per pouch\u003c\/td\u003e\n\u003ctd\u003e30 per pack on Balego’s case listing\u003c\/td\u003e\n\u003ctd\u003e2,000 per case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eStandard hospital-wide monitoring\u003c\/td\u003e\n\u003ctd\u003eMotion, sweat, stress testing, and Holter workflows\u003c\/td\u003e\n\u003ctd\u003eBrief resting diagnostic recordings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 450\/850 family as general monitoring electrodes and the 530\/930 family as multipurpose products for applications such as adult stress testing, Holter monitoring, and diaphoretic patients. Balego’s 5500 listing is a radiolucent diagnostic tab electrode rather than a foam snap monitoring electrode. \u003c\/p\u003e\n\u003ch3\u003eChoose the Medi-Trace 450 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe facility needs a standard adult snap monitoring electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral hospital-wide monitoring is the primary application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluid-resistant conformable foam is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-radiolucent construction is acceptable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA choice of 3-, 5-, or 50-electrode pouch formats is useful.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandardization across several clinical units is a priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the Medi-Trace 530 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe patient is likely to perspire heavily.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode security during movement is a greater concern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe workflow includes stress testing or Holter monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA larger teardrop-style foam surface is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the 5500 Diagnostic Tab when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe procedure is a resting diagnostic ECG rather than continuous monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible tab or grabber leads are used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA high-volume 2,000-electrode format is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA radiolucent diagnostic electrode is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a smaller resting diagnostic supply, consider the \u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003eKendall 5400 Resting Tab Electrodes, pack of 300\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eMedi-Trace 450 vs. 850 radiolucent electrodes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eMedi-Trace 450 Series\u003c\/th\u003e\n\u003cth\u003eMedi-Trace 850 Series\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring purpose\u003c\/td\u003e\n\u003ctd\u003eGeneral adult ECG monitoring\u003c\/td\u003e\n\u003ctd\u003eGeneral adult ECG monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking\u003c\/td\u003e\n\u003ctd\u003eFoam\u003c\/td\u003e\n\u003ctd\u003eFoam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive adhesive hydrogel\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiolucent\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppropriate choice when imaging is expected\u003c\/td\u003e\n\u003ctd\u003eMay require removal according to protocol\u003c\/td\u003e\n\u003ctd\u003eDesigned as the radiolucent version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Balego page\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNot currently linked as a separate product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe 850 Series is the radiolucent counterpart to the 450 Series. When a patient is likely to undergo imaging, the clinical team should select electrodes according to the imaging protocol rather than assuming the 450 can remain in place. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow to apply Medi-Trace 450 electrodes\u003c\/h1\u003e\n\u003cp\u003eFollow the ECG monitor instructions and the healthcare facility’s skin-preparation and placement protocol.\u003c\/p\u003e\n\u003ch2\u003e1. Confirm the correct electrode\u003c\/h2\u003e\n\u003cp\u003eVerify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdult patient suitability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSnap-lead compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequired number of electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring rather than diagnostic or stimulation use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhether radiolucent electrodes are needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackage expiration and pouch condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Prepare the skin\u003c\/h2\u003e\n\u003cp\u003eApply only to an appropriate skin site selected under the monitoring protocol. The area should generally be:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eClean\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFree of lotion and oil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFree of excessive perspiration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrepared according to facility procedure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExcess hair may need to be clipped under facility policy so that the complete hydrogel surface contacts the skin.\u003c\/p\u003e\n\u003ch2\u003e3. Connect the monitoring lead\u003c\/h2\u003e\n\u003cp\u003eDepending on institutional workflow, the lead may be snapped to the electrode before or after placement. Ensure that the snap is fully engaged without twisting or damaging the pad.\u003c\/p\u003e\n\u003ch2\u003e4. Remove the electrode from the liner\u003c\/h2\u003e\n\u003cp\u003eUse the courtesy lift tab or foam edge. Avoid touching the central conductive hydrogel unnecessarily.\u003c\/p\u003e\n\u003ch2\u003e5. Apply the electrode\u003c\/h2\u003e\n\u003cp\u003ePosition the pad according to the prescribed lead configuration. Press from the center outward so the hydrogel and foam lie flat without\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFolded edges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir pockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcessive tension\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGel contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePartial skin contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e6. Verify the tracing\u003c\/h2\u003e\n\u003cp\u003eConfirm that the monitor receives an appropriate signal. When artifact or lead-off warnings occur, inspect the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSkin preparation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSnap connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-wire condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePad adhesion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePatient movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode age or contamination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e7. Remove using the lift tab\u003c\/h2\u003e\n\u003cp\u003eDisconnect the lead as directed and gently lift the electrode from the designated tab or foam edge. Do not pull the patient lead to remove the pad.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003ePouch storage and open-pouch performance\u003c\/h1\u003e\n\u003cp\u003eThe 450 Series hydrogel can provide quality tracings for up to 45 days after pouch opening. Actual suitability still depends on the pouch being handled and stored according to its labeling and on each electrode remaining clean, moist, and undamaged. \u003c\/p\u003e\n\u003cp\u003eAfter opening:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eKeep unused electrodes in the original pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose or reseal the pouch as directed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtect the hydrogel from air exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep electrodes away from excessive heat and direct sunlight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not use a dry, contaminated, damaged, or expired electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow the expiration date and open-pouch policy printed on the current package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not return a used electrode to the pouch.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eTroubleshooting ECG monitoring problems\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProblem\u003c\/th\u003e\n\u003cth\u003ePossible cause\u003c\/th\u003e\n\u003cth\u003eRecommended check\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead-off warning\u003c\/td\u003e\n\u003ctd\u003eSnap is disconnected\u003c\/td\u003e\n\u003ctd\u003eReconnect the ECG lead securely\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA lead-off warning persists\u003c\/td\u003e\n\u003ctd\u003eThe electrode is lifting\u003c\/td\u003e\n\u003ctd\u003eReplace the electrode after preparing the skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoisy tracing\u003c\/td\u003e\n\u003ctd\u003ePatient movement\u003c\/td\u003e\n\u003ctd\u003eReduce movement when clinically possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoisy tracing\u003c\/td\u003e\n\u003ctd\u003ePoor skin preparation\u003c\/td\u003e\n\u003ctd\u003eFollow facility skin-preparation protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent signal\u003c\/td\u003e\n\u003ctd\u003eDamaged lead wire\u003c\/td\u003e\n\u003ctd\u003eTest or replace the lead according to monitor policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe electrode will not adhere\u003c\/td\u003e\n\u003ctd\u003eMoisture, lotion, oil, or hair\u003c\/td\u003e\n\u003ctd\u003ePrepare a new site and use a fresh electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoam edge lifts\u003c\/td\u003e\n\u003ctd\u003eSkin contour or tension on lead\u003c\/td\u003e\n\u003ctd\u003eReposition the lead and replace the electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe gel appears dry\u003c\/td\u003e\n\u003ctd\u003eThe pouch was left open or electrode is old\u003c\/td\u003e\n\u003ctd\u003eDiscard and use a fresh electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnap pulls on the pad\u003c\/td\u003e\n\u003ctd\u003eThe lead wire is not adequately supported\u003c\/td\u003e\n\u003ctd\u003eRe-route or anchor the lead according to protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin becomes irritated\u003c\/td\u003e\n\u003ctd\u003eSensitivity, moisture, pressure, or adhesive reaction\u003c\/td\u003e\n\u003ctd\u003eRemove as clinically appropriate and assess the skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe electrode is visible during imaging\u003c\/td\u003e\n\u003ctd\u003eThe 450 Series is non-radioluscent.\u003c\/td\u003e\n\u003ctd\u003eFollow imaging protocol or select a radiolucent electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracing remains poor with fresh electrodes\u003c\/td\u003e\n\u003ctd\u003eMonitor, cable, placement, or patient factor\u003c\/td\u003e\n\u003ctd\u003eFollow the monitor manufacturer’s troubleshooting procedure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat are Kendall Medi-Trace 450 electrodes?\u003c\/h2\u003e\n\u003cp\u003eThey are disposable adult ECG\/EKG monitoring electrodes with foam backing, conductive adhesive hydrogel, and snap connectors. Cardinal Health positions them for general-purpose hospital monitoring. \u003c\/p\u003e\n\u003ch2\u003eWho currently supplies the Medi-Trace portfolio?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health currently includes Medi-Trace products in its ECG electrode portfolio. Cardinal Health acquired Medtronic’s patient-recovery product portfolio and has transitioned products in this group to Cardinal Health branding and packaging. Customers may therefore encounter older Kendall, Covidien, Medtronic, or newer Cardinal Health packaging depending on inventory age. \u003c\/p\u003e\n\u003ch2\u003eWhat size is the Medi-Trace 450?\u003c\/h2\u003e\n\u003cp\u003eA rectangular size of 1.438 × 1.656 inches, approximately 36.5 × 42.1 mm. \u003c\/p\u003e\n\u003ch2\u003eWhat connector does it use?\u003c\/h2\u003e\n\u003cp\u003eThe electrode has a snap connector for compatible ECG monitoring lead wires. It does not use the 2 mm pin connector commonly found on portable TENS and NMES pads. \u003c\/p\u003e\n\u003ch2\u003eIs the 450 Series radiolucent?\u003c\/h2\u003e\n\u003cp\u003eNo. The Medi-Trace 450 Series is non-radiolucent. Cardinal Health identifies the 850 Series as its radiolucent counterpart. \u003c\/p\u003e\n\u003ch2\u003eAre these resting diagnostic ECG electrodes?\u003c\/h2\u003e\n\u003cp\u003eThey are intended primarily for ECG monitoring. For a brief resting diagnostic ECG using tab or grabber leads, compare Balego’s \u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003e5500 Diagnostic Tab Electrodes\u003c\/a\u003e or \u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003e5400 Resting Tab Electrodes\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eAre they intended for stress testing or Holter monitoring?\u003c\/h2\u003e\n\u003cp\u003eThe 450 Series is Cardinal Health’s general-purpose monitoring option. For stress, Holter, active, or diaphoretic applications, the larger \u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eMedi-Trace 530 foam electrode\u003c\/a\u003e is the more specific product. \u003c\/p\u003e\n\u003ch2\u003eCan these electrodes be reused?\u003c\/h2\u003e\n\u003cp\u003eNo. They are disposable ECG monitoring electrodes and should not be reapplied after removal or transferred between patients. \u003c\/p\u003e\n\u003ch2\u003eDo they require separate electrode gel?\u003c\/h2\u003e\n\u003cp\u003eNo. The conductive adhesive hydrogel is already incorporated into the electrode. Adding gel could interfere with the adhesive and is not part of the product’s standard application. \u003c\/p\u003e\n\u003ch2\u003eAre they made with natural rubber latex?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health’s current ECG catalog states that its monitoring electrodes are not made with natural rubber latex. It also states that they are not made with DEHP or mercury. \u003c\/p\u003e\n\u003ch2\u003eAre they hypoallergenic?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health’s current 450 Series page does not label the product hypoallergenic. Use the documented “not made with natural rubber latex” wording rather than making a broader hypoallergenic claim.\u003c\/p\u003e\n\u003ch2\u003eHow long do they remain usable after opening the pouch?\u003c\/h2\u003e\n\u003cp\u003eCardinal Health states that the 450 Series can provide quality tracings for up to 45 days after pouch opening. Follow the current package’s storage, expiration, and open-pouch instructions, and discard any electrode that is dry, dirty, damaged, or no longer adheres properly. \u003c\/p\u003e\n\u003ch2\u003eCan they be used for TENS or NMES?\u003c\/h2\u003e\n\u003cp\u003eNo. ECG monitoring electrodes receive the heart’s electrical signal. TENS and NMES electrodes deliver stimulation current from a therapy device.\u003c\/p\u003e\n\u003cp\u003eFor stimulation pads, shop Balego’s \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan they be used for defibrillation?\u003c\/h2\u003e\n\u003cp\u003eNo. They are monitoring electrodes, not multifunction defibrillation or pacing pads.\u003c\/p\u003e\n\u003ch2\u003eWhy are there three order codes?\u003c\/h2\u003e\n\u003cp\u003eThe electrode construction is the same, but the pouch and case configurations differ:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e22450: 50 per pouch, 1,000 per case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e22453-: 3 per pouch, 600 per case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e22455-: 5 per pouch, 600 per case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eAdditional Recommended Resources\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003eMonitoring EKG\/ECG Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/530-foam-ecg-electrodes-kendall-medi-trace\"\u003eMedi-Trace 530 Foam ECG Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/5500-diagnostic-tab-electrode\"\u003e5500 Diagnostic Tab Resting EKG Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/resting-tab-5400-pack-of-300\"\u003e5400 Resting Tab Electrodes, Pack of 300\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\"\u003eEEG and ECG Diagnostic Supply Guides\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/ten20-vs-nuprep-when-to-use-each-product\"\u003eTen20 vs. NuPrep: When to Use Each Product\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eBalego Contact Page\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/price-guarantee\"\u003eBest Price Guarantee\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNuPrep and other skin-preparation products should be used only when permitted by the ECG electrode, monitor, and facility protocol. Our \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\"\u003ediagnostic guide\u003c\/a\u003e explains the distinction between skin preparation and conductive pastes used in EEG and ECG workflows. \u003ccode\u003e\u003c\/code\u003e\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e","brand":"Cardinal Health","offers":[{"title":"22450 (50\/pack - 1000\/case)","offer_id":48859417182463,"sku":null,"price":219.95,"currency_code":"USD","in_stock":true},{"title":"22453- (3\/pack - 600\/case)","offer_id":48859417215231,"sku":null,"price":199.95,"currency_code":"USD","in_stock":true},{"title":"22455- (5\/pack - 600\/case","offer_id":48859417247999,"sku":null,"price":167.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Kendall_Medi-Trace_450SeriesFoamElectrodes.png?v=1784575419","url":"https:\/\/balego-stores.myshopify.com\/products\/kendall-medi-trace-450","provider":"Balego","version":"1.0","type":"link"}