{"product_id":"norco-iontophoresis-electrodes","title":"Norco® Buffered Iontophoresis Electrodes | 12 Kits\/Box","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_fba40f1824620837\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_fba40f1824620837\" aria-live=\"polite\" aria-busy=\"false\" dir=\"ltr\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eNorco® Buffered Iontophoretic Delivery Kit\u003c\/strong\u003e from Balego is a professional iontophoresis electrode kit for clinician-directed drug-delivery workflows using compatible powered iontophoresis devices. Each box contains \u003cstrong\u003e12 individually packaged treatment kits\u003c\/strong\u003e, and each kit includes one active drug-delivery electrode, one return electrode, and one alcohol prep pad.\u003c\/p\u003e\n\u003cp\u003eNorco® buffered iontophoresis electrodes are designed for clinics that want a ready-to-use electrode kit with \u003cstrong\u003ecarbon-Ag\/AgCl technology\u003c\/strong\u003e, an absorbent drug matrix, broad adhesive areas, and flexible size choices. The product is available in small square\u003cstrong\u003e 1.5cc\u003c\/strong\u003e, medium square\u003cstrong\u003e 2.5cc\u003c\/strong\u003e, \u003cstrong\u003ebutterfly 2.0cc\u003c\/strong\u003e, and large square\u003cstrong\u003e 4.0cc\u003c\/strong\u003e options so clinicians can match fill volume and electrode shape to the treatment site and ordered protocol.\u003c\/p\u003e\n\u003cp\u003ePair with \u003ca href=\"https:\/\/www.balego.com\/products\/activadose-ii-dose-controller-system\" target=\"_blank\"\u003eActivaDose® II Iontophoresis Dose Controller\u003c\/a\u003e\u003cbr\u003eRead \u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-frequently-asked-questions\/iontophoresis-frequently-asked-questions\"\u003eIontophoresis Frequently Asked Questions\u003c\/a\u003e\u003cbr\u003eRead \u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-frequently-asked-questions\/iontophoresis-reimbursement-codes-a-quick-billing-documentation-guide\"\u003eIontophoresis Reimbursement Codes and Documentation Guide\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick Product Summary\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eNorco® Buffered Iontophoretic Delivery Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eBuffered iontophoresis electrode treatment kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eNorco® \/ North Coast Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego Ref\u003c\/td\u003e\n\u003ctd\u003eNORCO-IONTOPHORESIS-ELECTRODES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault visible Balego SKU\u003c\/td\u003e\n\u003ctd\u003eNC89250B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBox quantity\u003c\/td\u003e\n\u003ctd\u003e12 individual treatment kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit components\u003c\/td\u003e\n\u003ctd\u003e1 active electrode, 1 return electrode, 1 alcohol prep pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eCarbon-Ag\/AgCl construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose support\u003c\/td\u003e\n\u003ctd\u003eUp to 80 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrug matrix\u003c\/td\u003e\n\u003ctd\u003eHighly absorbent matrix with no messy hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn electrode\u003c\/td\u003e\n\u003ctd\u003eLarge surface-area return electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive design\u003c\/td\u003e\n\u003ctd\u003eBroad adhesive areas on electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterials\u003c\/td\u003e\n\u003ctd\u003eNonsensitizing, hypoallergenic, medical-grade materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatex status\u003c\/td\u003e\n\u003ctd\u003eNot made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize options\u003c\/td\u003e\n\u003ctd\u003eSmall Square 1.5 cc, Medium Square 2.5 cc, Butterfly 2.0 cc, Large Square 4.0 cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice compatibility\u003c\/td\u003e\n\u003ctd\u003eDesigned for use with most powered iontophoresis delivery devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eIontophoresis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulk discount\u003c\/td\u003e\n\u003ctd\u003e5% off 5+ units; 10% off 10+ units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping\u003c\/td\u003e\n\u003ctd\u003eFree shipping across USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick Answer: Which Norco® Size Should You Choose?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical Need\u003c\/th\u003e\n\u003cth\u003eRecommended Size\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall treatment area\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSmall Square, 1.5cc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLowest fill volume and compact square footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral-purpose clinic use\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMedium Square, 2.5cc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBalanced fill volume for many standard workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContoured or non-square placement\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eButterfly, 2.0cc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eButterfly shape may fit certain anatomical areas better than a square\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLargest drug matrix volume\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLarge Square, 4.0cc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHighest fill volume in the Norco® family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic starter inventory\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMedium + Butterfly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCovers a practical everyday square option plus a contoured option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroad iontophoresis inventory\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAll four sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGives clinicians flexibility by treatment site, fill volume, and shape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eComplete Size and SKU Comparison\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBalego Size Option\u003c\/th\u003e\n\u003cth\u003eCommon Manufacturer SKU\u003c\/th\u003e\n\u003cth align=\"right\"\u003eFill Volume\u003c\/th\u003e\n\u003cth\u003eShape\u003c\/th\u003e\n\u003cth align=\"right\"\u003eBox Quantity\u003c\/th\u003e\n\u003cth\u003eBest Fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd\u003eNC89250B\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5cc\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eSmaller treatment areas and lower fill-volume needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd\u003eNC89251B\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.5cc\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose professional iontophoresis workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd\u003eNC89255B\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eContoured placement areas or non-square fit preference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd\u003eNC89252B\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4.0 cc\u003c\/td\u003e\n\u003ctd\u003eSquare\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e12 kits\/box\u003c\/td\u003e\n\u003ctd\u003eLarger fill-volume needs and broader square placement areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose Norco® Buffered Iontophoretic Delivery Kits?\u003c\/h2\u003e\n\u003ch3\u003e1. Buffered Carbon-Ag\/AgCl Technology\u003c\/h3\u003e\n\u003cp\u003eThe Norco® kit is designed around carbon-Ag\/AgCl technology to support controlled iontophoresis delivery and pH-balanced performance up to 80 mA-min.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eWhy It Matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon-Ag\/AgCl construction\u003c\/td\u003e\n\u003ctd\u003eSupports consistent electrical characteristics during the session\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered delivery design\u003c\/td\u003e\n\u003ctd\u003eHelps support pH balance during iontophoresis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUp to 80 mA-min\u003c\/td\u003e\n\u003ctd\u003eFits common professional iontophoresis dosing workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive and return electrode pairing\u003c\/td\u003e\n\u003ctd\u003eProvides the two-electrode setup needed for powered iontophoresis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge return electrode surface\u003c\/td\u003e\n\u003ctd\u003eDesigned to lower sensation and improve comfort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfessional-use positioning\u003c\/td\u003e\n\u003ctd\u003eStrong fit for PT, sports medicine, rehab, and clinician-directed workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Absorbent Drug Matrix With No Messy Hydrogel\u003c\/h3\u003e\n\u003cp\u003eNorco® electrodes use a highly absorbent matrix rather than a messy hydrogel-style setup. This helps streamline treatment-room workflow while supporting even medication placement.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDrug Matrix Feature\u003c\/th\u003e\n\u003cth\u003ePractical Benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbent matrix\u003c\/td\u003e\n\u003ctd\u003eHelps hold solution during application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo messy hydrogel\u003c\/td\u003e\n\u003ctd\u003eCleaner setup and cleanup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFill-volume options\u003c\/td\u003e\n\u003ctd\u003eHelps match electrode to clinical need\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge adhesive areas\u003c\/td\u003e\n\u003ctd\u003eHelps maintain secure placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividually packaged kits\u003c\/td\u003e\n\u003ctd\u003eConvenient single-session workflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol prep pad included\u003c\/td\u003e\n\u003ctd\u003eSupports basic skin preparation before placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Four Size Options for Treatment-Site Flexibility\u003c\/h3\u003e\n\u003cp\u003eNo single iontophoresis electrode shape fits every patient or site. Norco® gives clinics four choices so the electrode can better match the treatment plan.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSize Feature\u003c\/th\u003e\n\u003cth\u003eWhy It Helps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd\u003eCompact option for smaller areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd\u003eBalanced everyday size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd\u003eLarger fill volume and broader footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd\u003eContoured option when a square electrode is not ideal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 kits per box\u003c\/td\u003e\n\u003ctd\u003ePractical for stocking and repeat clinical use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfessional packaging\u003c\/td\u003e\n\u003ctd\u003eHelps standardize treatment-room setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eHow Norco® Iontophoresis Electrodes Work\u003c\/h1\u003e\n\u003cp\u003eIontophoresis uses low-level direct current to help move ionized medication molecules through intact skin. In a powered setup, the medication is placed in the active electrode, the return electrode completes the circuit, and the iontophoresis device controls current and dose.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eStep\u003c\/th\u003e\n\u003cth\u003eProfessional Workflow\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003ctd\u003eConfirm the clinician order, medication, polarity, dose, current, and treatment site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2\u003c\/td\u003e\n\u003ctd\u003eChoose Small, Medium, Large, or Butterfly based on fill volume and placement area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e3\u003c\/td\u003e\n\u003ctd\u003eInspect skin and confirm the site is appropriate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eClean the skin using the included alcohol prep pad or facility protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e5\u003c\/td\u003e\n\u003ctd\u003eFill the active electrode drug matrix according to the product and medication instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e6\u003c\/td\u003e\n\u003ctd\u003ePlace the active electrode over the treatment site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e7\u003c\/td\u003e\n\u003ctd\u003ePlace the return electrode at the appropriate distance and location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e8\u003c\/td\u003e\n\u003ctd\u003eConnect both electrodes to the compatible iontophoresis device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e9\u003c\/td\u003e\n\u003ctd\u003eSet dose\/current according to the prescribed protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e10\u003c\/td\u003e\n\u003ctd\u003eMonitor comfort, skin response, current delivery, and treatment completion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e11\u003c\/td\u003e\n\u003ctd\u003eRemove and discard the single-use kit after the session\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e12\u003c\/td\u003e\n\u003ctd\u003eDocument dose, current, time, polarity, medication, site, and patient response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat Does “80 mA-min” Mean?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003emA-min\u003c\/strong\u003e means milliamp-minutes. It describes the total iontophoresis dose as current multiplied by time.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth align=\"right\"\u003eDose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.0 mA for 10 minutes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.0 mA for 20 minutes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e40 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.0 mA for 20 minutes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e80 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.0 mA for 40 minutes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e80 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe clinician selects the dose, current, and time according to the medication, treatment goal, patient tolerance, device instructions, and facility protocol.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBest Use Cases by Clinical Setting\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eWhy Norco® Fits\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical therapy clinic\u003c\/td\u003e\n\u003ctd\u003eReady-to-use electrode kits for professional iontophoresis sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSports medicine clinic\u003c\/td\u003e\n\u003ctd\u003eMultiple sizes for localized tendon, soft-tissue, or superficial workflows when ordered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRehabilitation department\u003c\/td\u003e\n\u003ctd\u003e12 individually packaged kits support repeat treatments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOccupational therapy\u003c\/td\u003e\n\u003ctd\u003eUseful for hand, wrist, elbow, and upper-extremity treatment areas when clinically appropriate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePodiatry \/ foot and ankle rehab\u003c\/td\u003e\n\u003ctd\u003eSize options help match superficial treatment sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrthopedic clinic\u003c\/td\u003e\n\u003ctd\u003eSupports clinician-directed localized drug-delivery workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeaching lab\u003c\/td\u003e\n\u003ctd\u003eA clear active\/return electrode setup helps train staff and students\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-provider clinic\u003c\/td\u003e\n\u003ctd\u003eStandard packaging supports protocol consistency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch1\u003eNorco® Size Selection Guide\u003c\/h1\u003e\n\u003ch2\u003eChoose Small Square, 1.5 cc, if:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area is smaller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA compact square footprint is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe ordered protocol calls for a lower fill volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinician wants the smallest Norco® square option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe electrode must fit around a smaller anatomical site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Medium Square, 2.5cc, if:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou want the best general-purpose Norco® option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants one default square size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment site does not require the smallest or largest matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2.5cc fill volume matches the protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou are standardizing a common powered iontophoresis workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Butterfly, 2.0 cc, if:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area may benefit from a contoured shape.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA square electrode does not fit the site as well.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinician wants a non-square electrode option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2.0cc fill volume is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlacement around curved or irregular areas is the priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Large Square, 4.0 cc, if:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinician needs the largest Norco® fill volume.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area can accommodate a larger square electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA broader matrix footprint is desired.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinical protocol calls for more fill capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic wants a larger square option in stock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003ch2\u003eBest Use Cases by Fill Volume\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eFill Volume\u003c\/th\u003e\n\u003cth\u003eNorco® Option\u003c\/th\u003e\n\u003cth\u003eBest Fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1.5cc\u003c\/td\u003e\n\u003ctd\u003eSmall Square\u003c\/td\u003e\n\u003ctd\u003eSmaller treatment areas and lower solution volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.0 cc\u003c\/td\u003e\n\u003ctd\u003eButterfly\u003c\/td\u003e\n\u003ctd\u003eContoured placement and non-square shape preference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e2.5cc\u003c\/td\u003e\n\u003ctd\u003eMedium Square\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose clinic use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e4.0 cc\u003c\/td\u003e\n\u003ctd\u003eLarge Square\u003c\/td\u003e\n\u003ctd\u003eLarger matrix capacity and broader square footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat Comes in Each Norco® Treatment Kit?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Item\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive electrode\u003c\/td\u003e\n\u003ctd\u003eHolds the medication or solution for iontophoresis delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn electrode\u003c\/td\u003e\n\u003ctd\u003eCompletes the electrical circuit and helps disperse current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlcohol prep pad\u003c\/td\u003e\n\u003ctd\u003eCleans the skin before electrode placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndividual pouch\u003c\/td\u003e\n\u003ctd\u003eSupports single-treatment organization and clinic inventory control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMedication is not included. The clinician or prescriber determines the medication, polarity, dose, current, time, and treatment site.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatibility Checklist Before Ordering\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatibility Question\u003c\/th\u003e\n\u003cth\u003eWhat to Verify\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo you have a powered iontophoresis device?\u003c\/td\u003e\n\u003ctd\u003eNorco® kits require a compatible iontophoresis delivery device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs the dose range appropriate?\u003c\/td\u003e\n\u003ctd\u003eNorco® is positioned for delivery up to 80 mA-min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWhich size is needed?\u003c\/td\u003e\n\u003ctd\u003eChoose Small, Medium, Butterfly, or Large based on fill volume and site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs the medication compatible with iontophoresis?\u003c\/td\u003e\n\u003ctd\u003eMedication must be selected under clinician\/prescriber direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDo you know polarity?\u003c\/td\u003e\n\u003ctd\u003eMatch the medication’s ionic charge and electrode polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs the skin intact?\u003c\/td\u003e\n\u003ctd\u003eDo not apply over broken, irritated, or compromised skin unless specifically directed by qualified personnel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs the patient appropriate for iontophoresis?\u003c\/td\u003e\n\u003ctd\u003eScreen for contraindications, sensitivity, allergies, and precautions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAre you documenting the session?\u003c\/td\u003e\n\u003ctd\u003eRecord medication, dose, current, time, polarity, site, and response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eDocumentation Checklist for Professional Use\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDocumentation Item\u003c\/th\u003e\n\u003cth\u003eWhy It Matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication name and concentration\u003c\/td\u003e\n\u003ctd\u003eSupports clinical and billing documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eConfirms correct active electrode setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDose in mA-min\u003c\/td\u003e\n\u003ctd\u003eDescribes total delivered dose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent in mA\u003c\/td\u003e\n\u003ctd\u003eHelps explain treatment time and tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment time\u003c\/td\u003e\n\u003ctd\u003eSupports procedure documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode size and type\u003c\/td\u003e\n\u003ctd\u003eExplains fill volume and placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment site\u003c\/td\u003e\n\u003ctd\u003eConfirms location and medical necessity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin status before\/after\u003c\/td\u003e\n\u003ctd\u003eTracks irritation, redness, or adverse response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient tolerance\u003c\/td\u003e\n\u003ctd\u003eSupports clinical reasoning and follow-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLot \/ product details if required\u003c\/td\u003e\n\u003ctd\u003eHelps facility quality documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eHelpful resource: \u003ca href=\"https:\/\/www.balego.com\/blogs\/iontophoresis-frequently-asked-questions\/iontophoresis-reimbursement-codes-a-quick-billing-documentation-guide\"\u003eIontophoresis Reimbursement Codes: A Quick Billing \u0026amp; Documentation Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSafety and Professional Use Notes\u003c\/h2\u003e\n\u003cp\u003eNorco® Buffered Iontophoretic Delivery Kits should be used only according to product labeling, the iontophoresis device instructions, medication labeling, prescriber direction, and facility protocols.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Topic\u003c\/th\u003e\n\u003cth\u003eGuidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfessional direction\u003c\/td\u003e\n\u003ctd\u003eUse under appropriate clinician or prescriber direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedication\u003c\/td\u003e\n\u003ctd\u003eMedication is supplied separately and must match the treatment plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin\u003c\/td\u003e\n\u003ctd\u003eApply to clean, intact skin unless qualified medical personnel direct otherwise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd\u003eMatch medication charge to correct electrode polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent and dose\u003c\/td\u003e\n\u003ctd\u003eFollow the prescribed mA and mA-min limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensation\u003c\/td\u003e\n\u003ctd\u003eStop or adjust if burning, sharp discomfort, or unusual symptoms occur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin response\u003c\/td\u003e\n\u003ctd\u003eMonitor for redness, irritation, vesicles, dryness, or dermatitis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContraindications\u003c\/td\u003e\n\u003ctd\u003eScreen for implanted electrical devices, pregnancy, seizure history, heart conditions, metal implants, open wounds, and other risks according to facility policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle use\u003c\/td\u003e\n\u003ctd\u003eTreat each kit as a single-treatment disposable setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatex\u003c\/td\u003e\n\u003ctd\u003eProduct is not made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eDispose according to facility policy after treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThis content is for product selection and clinical workflow education only. It is not medical advice and does not replace device instructions, medication labeling, prescriber orders, or facility protocols.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eNorco® Buffered Iontophoretic Delivery Kit\u003c\/strong\u003e is a professional disposable electrode kit for powered iontophoresis drug delivery workflows. Each box includes \u003cstrong\u003e12 individually packaged treatment kits\u003c\/strong\u003e, and each kit includes one active electrode, one return electrode, and one alcohol prep pad.\u003c\/p\u003e\n\u003cp\u003eNorco® electrodes use \u003cstrong\u003ecarbon-Ag\/AgCl technology\u003c\/strong\u003e and a highly absorbent drug matrix designed to support controlled iontophoresis delivery up to \u003cstrong\u003e80 mA-min\u003c\/strong\u003e. The large return electrode surface helps disperse current, while broad adhesive areas help keep both electrodes secure during the session. The kit is made from nonsensitizing, hypoallergenic, medical-grade materials and is not made with natural rubber latex.\u003c\/p\u003e\n\u003cp\u003eChoose \u003cstrong\u003eSmall Square 1.5 cc\u003c\/strong\u003e for smaller placement areas; \u003cstrong\u003eMedium Square 2.5 cc\u003c\/strong\u003e for general-purpose workflows; \u003cstrong\u003eButterfly 2.0 cc\u003c\/strong\u003e for contoured non-square placement; and \u003cstrong\u003eLarge Square 4.0 cc\u003c\/strong\u003e when a larger drug matrix volume is needed. \u003c\/p\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003ch2\u003eBuyer’s Guide\u003c\/h2\u003e\n\u003ch3\u003eChoose the Norco® Buffered Iontophoretic Delivery Kit if:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYour clinic uses powered iontophoresis devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need disposable drug-delivery and return electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a buffered carbon-Ag\/AgCl electrode system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need options for small, medium, large, or butterfly placement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want 12 individual treatment kits per box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a kit with an included alcohol prep pad.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou need a product not made with natural rubber latex.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou are replacing \u003cstrong\u003eNC89250B\u003c\/strong\u003e, \u003cstrong\u003eNC89251B\u003c\/strong\u003e, \u003cstrong\u003eNC89252B\u003c\/strong\u003e, or \u003cstrong\u003eNC89255B\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a professional iontophoresis kit from Balego’s iontophoresis category.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Norco® Buffered Iontophoretic Delivery Kit?\u003c\/h3\u003e\n\u003cp\u003eIt is a professional disposable iontophoresis electrode kit for powered iontophoresis drug-delivery workflows. Each box contains 12 treatment kits.\u003c\/p\u003e\n\u003ch3\u003eWhat comes in each kit?\u003c\/h3\u003e\n\u003cp\u003eEach individual treatment kit includes one active electrode, one return electrode, and one alcohol prep pad.\u003c\/p\u003e\n\u003ch3\u003eHow many kits are in a box?\u003c\/h3\u003e\n\u003cp\u003eEach box includes \u003cstrong\u003e12 individual treatment kits\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat sizes are available?\u003c\/h3\u003e\n\u003cp\u003eBalego lists \u003cstrong\u003eSmall Square 1.5cc\u003c\/strong\u003e, \u003cstrong\u003eMedium Square 2.5cc\u003c\/strong\u003e, \u003cstrong\u003eButterfly 2.0cc\u003c\/strong\u003e, and \u003cstrong\u003eLarge Square 4.0cc\u003c\/strong\u003e options.\u003c\/p\u003e\n\u003ch3\u003eWhat is the default Balego SKU?\u003c\/h3\u003e\n\u003cp\u003eBalego currently shows \u003cstrong\u003eNC89250B\u003c\/strong\u003e as the default visible SKU.\u003c\/p\u003e\n\u003ch3\u003eWhat are the common manufacturer SKU numbers?\u003c\/h3\u003e\n\u003cp\u003eCommonly listed manufacturer SKUs are \u003cstrong\u003eNC89250B\u003c\/strong\u003e for Small Square, \u003cstrong\u003eNC89251B\u003c\/strong\u003e for Medium Square, \u003cstrong\u003eNC89252B\u003c\/strong\u003e for Large Square, and \u003cstrong\u003eNC89255B\u003c\/strong\u003e for Butterfly.\u003c\/p\u003e\n\u003ch3\u003eWhat is carbon-Ag\/AgCl technology?\u003c\/h3\u003e\n\u003cp\u003eCarbon-Ag\/AgCl refers to carbon and silver\/silver chloride conductive technology used to support consistent current flow during iontophoresis.\u003c\/p\u003e\n\u003ch3\u003eWhat does buffered iontophoresis mean?\u003c\/h3\u003e\n\u003cp\u003eBuffered iontophoresis refers to electrode design intended to support pH balance during treatment, which may help comfort and current delivery.\u003c\/p\u003e\n\u003ch3\u003eWhat does \"80 mA-min\" mean?\u003c\/h3\u003e\n\u003cp\u003e80 mA-min is a dose measure equal to current multiplied by time. For example, 4 mA for 20 minutes equals 80 mA-min.\u003c\/p\u003e\n\u003ch3\u003eDoes this kit include medication?\u003c\/h3\u003e\n\u003cp\u003eNo. Medication is not included. Medication selection, concentration, polarity, and use should be directed by the prescriber or clinician.\u003c\/p\u003e\n\u003ch3\u003eDoes this kit require a separate iontophoresis device?\u003c\/h3\u003e\n\u003cp\u003eYes. Norco® kits are designed for use with compatible powered iontophoresis delivery devices.\u003c\/p\u003e\n\u003ch3\u003eCan this be used with ActivaDose® II?\u003c\/h3\u003e\n\u003cp\u003eIt may be used with compatible powered iontophoresis devices such as the ActivaDose® II Dose Controller when the device, lead wires, electrode instructions, and facility protocol match.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as IontoPATCH®?\u003c\/h3\u003e\n\u003cp\u003eNo. Norco® is a disposable electrode kit for a powered device. IontoPATCH® is a self-contained wearable patch family that does not require an external controller.\u003c\/p\u003e\n\u003ch3\u003eIs this the same as ACTIVApatch®?\u003c\/h3\u003e\n\u003cp\u003eNo. Norco® is a wired electrode kit for a powered device. ACTIVApatch® is a self-powered patch system.\u003c\/p\u003e\n\u003ch3\u003eAre these electrodes reusable?\u003c\/h3\u003e\n\u003cp\u003eNo. Treat each kit as a single-treatment disposable setup according to product and facility instructions.\u003c\/p\u003e\n\u003ch3\u003eAre these made with natural rubber latex?\u003c\/h3\u003e\n\u003cp\u003eAvailable product information states they are \u003cstrong\u003enot made with natural rubber latex\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhich size is best for general clinic use?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMedium Square 2.5cc\u003c\/strong\u003e option is the best general-purpose starting point for many clinics.\u003c\/p\u003e\n\u003ch3\u003eWhich size has the largest fill volume?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eLarge Square 4.0cc\u003c\/strong\u003e option has the largest listed fill volume.\u003c\/p\u003e\n\u003ch3\u003eWhich size is best for contoured areas?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eButterfly 2.0 cc\u003c\/strong\u003e option is the non-square shape and may fit certain contours better.\u003c\/p\u003e\n\u003ch3\u003eDoes Balego offer bulk discounts?\u003c\/h3\u003e\n\u003cp\u003eYes. Balego lists \u003cstrong\u003e5% off when buying 5+ units\u003c\/strong\u003e and \u003cstrong\u003e10% off when buying 10+ units\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDoes Balego offer free shipping?\u003c\/h3\u003e\n\u003cp\u003eYes. Free shipping across the USA for this product.\u003c\/p\u003e\n\u003ch3\u003eDoes Balego offer a best-price guarantee?\u003c\/h3\u003e\n\u003cp\u003eYes. We will match competitor pricing when customers show a competing offer.\u003c\/p\u003e\n\u003chr\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cem\u003eNorco iontophoresis electrodes, Norco Buffered Iontophoretic Delivery Kit, buffered iontophoresis delivery kit, iontophoresis electrodes, iontophoresis electrode kit, \u003cspan style=\"font-size: 0.875rem;\"\u003eNC89250B, NC89251B, NC89252B, NC89255B, Norco iontophoresis small square, Norco iontophoresis medium square, Norco iontophoresis butterfly, Norco iontophoresis large square, carbon Ag\/AgCl iontophoresis electrodes, buffered return electrode, 80 mA-min iontophoresis electrodes, iontophoresis kits 12 per box, drug delivery electrode, iontophoresis electrodes for ActivaDose II, Balego iontophoresis supplies\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"North Coast Medical","offers":[{"title":"Small Square 1.5cc","offer_id":48796692513023,"sku":"NC89250B","price":74.95,"currency_code":"USD","in_stock":true},{"title":"Medium Square 2.5cc","offer_id":48796692545791,"sku":"NC89251B","price":76.95,"currency_code":"USD","in_stock":true},{"title":"Butterfly 2.0cc","offer_id":48796692611327,"sku":"NC89255B","price":76.95,"currency_code":"USD","in_stock":true},{"title":"Large Square 4.0cc","offer_id":48796692578559,"sku":"NC89252B","price":82.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/nc89252b.jpg?v=1783339377","url":"https:\/\/balego-stores.myshopify.com\/products\/norco-iontophoresis-electrodes","provider":"Balego","version":"1.0","type":"link"}