{"product_id":"redux-electrolyte-paste","title":"Parker Labs Redux Electrolyte Paste 67-05 | ECG \u0026 Defibrillation","description":"\u003ch2\u003eRedux® Electrolyte Paste 67-05 – ECG, Short-Term Monitoring \u0026amp; Defibrillation\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRedux Electrolyte Paste\u003c\/strong\u003e by Parker Laboratories is a water-based, abrasive, electrically conductive contact paste recommended for \u003cstrong\u003eshort-term patient monitoring, ECG\/EKG procedures, and defibrillation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts conductive formulation helps establish electrical contact between intact skin and compatible electromedical electrodes, paddles, or other patient-contact components. The abrasive characteristic distinguishes Redux Paste from smoother, non-abrasive products such as \u003ca href=\"https:\/\/www.balego.com\/products\/redux-electrolyte-gel\"\u003eRedux Electrolyte Gel\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eRedux Paste is also bacteriostatic and water-soluble. It is supplied in a \u003cstrong\u003e142 g\/5 oz tube\u003c\/strong\u003e under Parker Laboratories' product number \u003cstrong\u003e67-05\u003c\/strong\u003e. The product is nonsterile and intended only for external use on intact, unbroken skin.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e Use Redux Paste only when the instructions for the ECG system, monitoring electrode, defibrillator, paddle, or related electromedical equipment permit a separately applied conductive paste. Do not add it beneath a pre-gelled disposable electrode or multifunction defibrillation pad unless the equipment manufacturer specifically directs that use. Parker instructs users to follow the connected electromedical device’s instructions for application. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrically conductive electrolyte paste\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for short-term monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for routine ECG\/EKG procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for compatible defibrillation procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater-based formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbrasive paste consistency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacteriostatic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater-soluble\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNonsterile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor external use on intact, unbroken skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoves with a moistened soft cloth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eParker Laboratories product number 67-05\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent manufacturer size: 142 g\/5 oz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTen tubes per manufacturer box\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFive boxes or 50 tubes per manufacturer case\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo special handling requirements stated in the current IFU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtect from direct sunlight\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eQuick specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eRedux Electrolyte Paste\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eParker Laboratories, Inc.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRedux®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct number\/MPN\u003c\/td\u003e\n\u003ctd\u003e67-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct category\u003c\/td\u003e\n\u003ctd\u003eElectrically conductive electrolyte paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-listed uses\u003c\/td\u003e\n\u003ctd\u003eShort-term monitoring, ECG, and defibrillation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormula base\u003c\/td\u003e\n\u003ctd\u003eWater-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbrasive\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacteriostatic\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eNo adhesive claim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater-soluble\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube contents\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e142 g\/5 oz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego purchase unit\u003c\/td\u003e\n\u003ctd\u003eOne tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer box\u003c\/td\u003e\n\u003ctd\u003e10 tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer case\u003c\/td\u003e\n\u003ctd\u003e5 boxes\/50 tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin application\u003c\/td\u003e\n\u003ctd\u003eExternal use on intact, unbroken skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication method\u003c\/td\u003e\n\u003ctd\u003eFollow connected-device instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanup\u003c\/td\u003e\n\u003ctd\u003eMoistened soft cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandling\u003c\/td\u003e\n\u003ctd\u003eNo special handling required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eProtect from direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eFollow applicable nonhazardous-waste regulations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhat is Redux Electrolyte Paste?\u003c\/h1\u003e\n\u003cp\u003eRedux Paste is a contact medium placed between intact skin and compatible electromedical equipment. It helps complete the electrical interface when the equipment requires a separately applied paste.\u003c\/p\u003e\n\u003cp\u003eIt does not generate, measure, or control the electrical signal or therapeutic energy. The connected ECG machine, patient monitor, or defibrillator controls those functions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eRole\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedux Paste\u003c\/td\u003e\n\u003ctd\u003eProvides a conductive skin-to-equipment interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode or paddle\u003c\/td\u003e\n\u003ctd\u003eMakes the equipment’s patient connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG or monitoring system\u003c\/td\u003e\n\u003ctd\u003eRecords the patient’s electrical signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillator\u003c\/td\u003e\n\u003ctd\u003eControls energy selection and delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment instructions\u003c\/td\u003e\n\u003ctd\u003eDetermine whether paste is needed and how it is applied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhat does “abrasive” mean?\u003c\/h1\u003e\n\u003cp\u003eRedux Paste is formulated with an abrasive characteristic, unlike the non-abrasive Redux Gel. The page should not interpret “abrasive” as permission to scrub the skin aggressively or use the product as a general-purpose exfoliant.\u003c\/p\u003e\n\u003cp\u003eThe appropriate amount, pressure, and technique depend on the connected device, electrode, clinical protocol, and patient’s skin condition. Redux Paste is limited to intact, unbroken skin. \u003c\/p\u003e\n\u003cp\u003eIt is also different from \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e. NuPrep is a dedicated skin-preparation product used before compatible electrode placement. Redux Paste remains part of the conductive interface during an indicated procedure.\u003c\/p\u003e\n\u003ch1\u003eBacteriostatic does not mean sterile\u003c\/h1\u003e\n\u003cp\u003eParker identifies Redux Paste as both \u003cstrong\u003ebacteriostatic\u003c\/strong\u003e and \u003cstrong\u003enonsterile\u003c\/strong\u003e. Therefore, the page should not claim or imply that the paste:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSterilizes skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisinfects electrodes or paddles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCreates a sterile field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevents all bacterial growth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevents procedure-related infection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs appropriate for broken skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplaces infection-control procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp\u003eRedux Paste has a bacteriostatic formulation. It is nonsterile and intended only for external use on intact, unbroken skin.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eWhen Redux Paste may be appropriate:\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eWorkflow\u003c\/th\u003e\n\u003cth\u003ePotential fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-term patient monitoring\u003c\/td\u003e\n\u003ctd\u003eWhen the monitor and electrode instructions require a separate conductive paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine ECG\/EKG\u003c\/td\u003e\n\u003ctd\u003eWhen reusable or non-pregelled electrodes call for conductive paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd\u003eWhen compatible reusable paddles or equipment specifically permit a separate paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiuse diagnostic department\u003c\/td\u003e\n\u003ctd\u003eWhen short-term monitoring, ECG, and permitted defibrillation occur within the same facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment using integrated hydrogel\u003c\/td\u003e\n\u003ctd\u003eUsually no additional paste unless expressly directed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMany contemporary ECG electrodes and multifunction defibrillation pads are already pre-gelled. Additional paste can interfere with adhesion or alter the intended interface, so it should not be added automatically. This follows the instruction to use Redux according to the connected equipment’s directions.\u003c\/p\u003e\n\u003ch1\u003eWhat Redux Paste is not\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct category\u003c\/th\u003e\n\u003cth align=\"right\"\u003eIs Redux Paste that product?\u003c\/th\u003e\n\u003cth\u003eExplanation\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-term monitoring paste\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eManufacturer-listed indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine ECG contact medium\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eManufacturer-listed indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation contact paste\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when equipment permits\u003c\/td\u003e\n\u003ctd\u003eFollow the defibrillator or paddle instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile conductive medium\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eRedux Paste is nonsterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode adhesive\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo documented adhesive claim\u003c\/td\u003e\n\u003ctd\u003eIt should not be marketed as holding electrodes in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEEG cup-electrode adhesive paste\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCompare Ten20 for neurodiagnostic cup electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral skin scrub\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUse only as directed for compatible electromedical procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTENS\/NMES gel\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNot a listed indication reviewed\u003c\/td\u003e\n\u003ctd\u003eSelect a medium permitted by the stimulation device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound gel\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUse a dedicated acoustic coupling medium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-wound product\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eLimited to intact, unbroken skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment cleaner\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eIt is a patient-contact conductive medium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eRedux Paste vs. Redux Gel vs. Redux Creme\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/redux-electrolyte-paste\"\u003eRedux Electrolyte Paste\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/redux-electrolyte-gel\"\u003eRedux Electrolyte Gel\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/redux-electrolyte-creme\"\u003eRedux Electrolyte Creme\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParker product number\u003c\/td\u003e\n\u003ctd\u003e67-05\u003c\/td\u003e\n\u003ctd\u003e65-04\u003c\/td\u003e\n\u003ctd\u003e66-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent tube size\u003c\/td\u003e\n\u003ctd\u003e142 g\/5 oz\u003c\/td\u003e\n\u003ctd\u003e114 g\/4 oz\u003c\/td\u003e\n\u003ctd\u003e114 g\/4 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary use\u003c\/td\u003e\n\u003ctd\u003eShort-term monitoring, ECG, and defibrillation\u003c\/td\u003e\n\u003ctd\u003eRoutine ECG and defibrillation\u003c\/td\u003e\n\u003ctd\u003eRoutine ECG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd\u003eYes, when equipment permits\u003c\/td\u003e\n\u003ctd\u003eYes, when equipment permits\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNo—not indicated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormula\u003c\/td\u003e\n\u003ctd\u003eWater-based paste\u003c\/td\u003e\n\u003ctd\u003eWater-based gel\u003c\/td\u003e\n\u003ctd\u003eCosmetic-quality cream\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbrasive\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNot identified as abrasive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacteriostatic\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNot identified as bacteriostatic in current IFU\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterile\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eNo adhesive claim\u003c\/td\u003e\n\u003ctd\u003eNo adhesive claim\u003c\/td\u003e\n\u003ctd\u003eNo adhesive claim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eShort monitoring or procedures calling for abrasive conductive paste\u003c\/td\u003e\n\u003ctd\u003eRoutine ECG or defibrillation calling for a smooth gel\u003c\/td\u003e\n\u003ctd\u003eRoutine ECG when cream consistency is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChoose Redux Paste when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eShort-term monitoring is part of the workflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe equipment calls for an abrasive conductive paste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine ECG is being performed with compatible equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA defibrillator or paddle system specifically permits a separate paste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA bacteriostatic paste formulation is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eComparison with other conductive media\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eManufacturer-listed or Balego-documented fit\u003c\/th\u003e\n\u003cth align=\"right\"\u003eAdhesive?\u003c\/th\u003e\n\u003cth align=\"right\"\u003eAbrasive?\u003c\/th\u003e\n\u003cth align=\"right\"\u003eDefibrillation?\u003c\/th\u003e\n\u003cth\u003eMain distinction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/redux-electrolyte-paste\"\u003eRedux Paste\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShort-term monitoring, ECG, defibrillation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo claim\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when permitted\u003c\/td\u003e\n\u003ctd\u003eAbrasive, bacteriostatic paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECG, EMG, biofeedback and defibrillation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when permitted\u003c\/td\u003e\n\u003ctd\u003eMultipurpose saline electrode gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra 360\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eECG, TENS, monitoring and conductive carbon\/rubber electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eSalt-free, chloride-free STAY-WET gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive Conductive Adhesive Gel\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible EEG, EMG, TENS, and related workflows\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eConductivity plus temporary adhesive hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 Conductive Paste\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEEG, EP, PSG, MSLT, and non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eThick adhesive paste for cup electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePreparation before compatible EEG, ECG, and related electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMildly\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003ePrepares skin and helps lower impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eRedux Paste vs. Ten20\u003c\/h1\u003e\n\u003cp\u003eRedux Paste and Ten20 are both called “conductive paste,” but their applications differ substantially.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eRedux Paste\u003c\/th\u003e\n\u003cth\u003eTen20 Conductive Paste\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary procedures\u003c\/td\u003e\n\u003ctd\u003eShort-term monitoring, ECG, and defibrillation\u003c\/td\u003e\n\u003ctd\u003eEEG, EP, PSG, MSLT, and neuromonitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode type\u003c\/td\u003e\n\u003ctd\u003eCompatible monitoring, ECG or defibrillation equipment requiring paste\u003c\/td\u003e\n\u003ctd\u003eNon-gelled neurodiagnostic cup electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive purpose\u003c\/td\u003e\n\u003ctd\u003eNo documented adhesive claim\u003c\/td\u003e\n\u003ctd\u003eHelps hold electrodes in position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbrasive\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd\u003eYes, when permitted\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStays during procedure\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eCardiac and acute-care electromedical contact\u003c\/td\u003e\n\u003ctd\u003eNeurodiagnostic electrode placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDo not substitute \u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 Conductive Paste\u003c\/a\u003e for Redux Paste in a defibrillation workflow. Likewise, Redux Paste should not be an EEG cup-electrode adhesive. \u003c\/p\u003e\n\u003cp\u003eFor additional neurodiagnostic context, see our \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/ten20-vs-nuprep-when-to-use-each-product\"\u003eTen20 vs. NuPrep: When to Use Each Product\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch1\u003eHow to use Redux Electrolyte Paste\u003c\/h1\u003e\n\u003cp\u003eThere is not one specified universal application amount because use depends on the connected electromedical equipment. The following product-page workflow stays within the manufacturer’s directions.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm equipment compatibility.\u003c\/strong\u003e Verify that the monitor, ECG electrode, defibrillator, or paddle system permits or requires a separate conductive paste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the tube.\u003c\/strong\u003e Do not use the product if the container is damaged or contamination is visible or suspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspect the application site.\u003c\/strong\u003e Apply only to intact, unbroken skin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAvoid contaminating the tube.\u003c\/strong\u003e Do not let the dispensing tip touch the patient, staff, electrode, paddle, instrument, glove, or another surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApply according to the equipment instructions.\u003c\/strong\u003e Use only the amount and placement specified by the device manufacturer or facility procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerform the procedure.\u003c\/strong\u003e Follow all ECG, monitoring, or defibrillator operating instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemove remaining paste.\u003c\/strong\u003e Parker states that Redux can be removed with a moistened soft cloth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClose and store the tube.\u003c\/strong\u003e Protect the product from direct sunlight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch1\u003eDefibrillation considerations\u003c\/h1\u003e\n\u003cp\u003eRedux Paste is indicated for defibrillation, but that does not mean it should be added to every defibrillator setup.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDefibrillation system\u003c\/th\u003e\n\u003cth\u003eGeneral product-page guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable paddles requiring conductive paste\u003c\/td\u003e\n\u003ctd\u003eRedux Paste may be appropriate when specifically permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultifunction adhesive defibrillation pads\u003c\/td\u003e\n\u003ctd\u003eDo not add paste unless the pad and defibrillator instructions expressly direct it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-gelled paddles or pads\u003c\/td\u003e\n\u003ctd\u003eAn additional contact medium is generally unnecessary unless specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnknown equipment\u003c\/td\u003e\n\u003ctd\u003eConsult the equipment manual before using Redux Paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eDefibrillation equipment controls energy delivery; Redux Paste only provides a conductive interface. Application amount, paddle placement, energy selection, charging, discharge, and safety procedures must follow the defibrillator manufacturer’s instructions. \u003c\/p\u003e\n\u003ch1\u003eInfection-control and tube handling\u003c\/h1\u003e\n\u003cp\u003eRedux Paste is sold in a multiuse tube. The manufacturer specifically instructs users not to let the tube tip contact patients, staff, or instruments.\u003c\/p\u003e\n\u003cp\u003eRecommended handling language:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDispense without touching the treatment surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not return unused paste to the tube.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplace the cap promptly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscard the product if contamination is suspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow the facility’s policy for nonsterile multiuse contact media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not use Redux Paste when a procedure requires sterile contact media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not apply it to broken or compromised skin.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSafety, storage, and disposal\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTopic\u003c\/th\u003e\n\u003cth\u003eRecommended page statement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eNonsterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin application\u003c\/td\u003e\n\u003ctd\u003eExternal use only on intact, unbroken skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContainer damage\u003c\/td\u003e\n\u003ctd\u003eDiscard if the package is damaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContamination\u003c\/td\u003e\n\u003ctd\u003eDiscard if contamination is present or suspected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube tip\u003c\/td\u003e\n\u003ctd\u003eDo not allow contact with patients, staff, or instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFollow the connected device’s instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanup\u003c\/td\u003e\n\u003ctd\u003eRemove with a moistened soft cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandling\u003c\/td\u003e\n\u003ctd\u003eNo special handling required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eProtect from direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eFollow federal, state, and local nonhazardous-waste requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003eNonsterile. For external use only on intact, unbroken skin. Use Redux Paste only as permitted by the connected electromedical equipment’s instructions. Discard the product if the tube is damaged or contamination is suspected. Do not allow the dispensing tip to touch the patient, staff, electrodes, paddles, or instruments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is Redux Electrolyte Paste used for?\u003c\/h2\u003e\n\u003cp\u003eRedux Paste for short-term monitoring, routine ECG procedures, and defibrillation. The connected device instructions must permit a separately applied conductive paste.\u003c\/p\u003e\n\u003ch2\u003eWho manufactures Redux Paste?\u003c\/h2\u003e\n\u003cp\u003eRedux Paste is manufactured by Parker Laboratories, Inc. \u003c\/p\u003e\n\u003ch2\u003eWhat is the manufacturer's product number?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e67-05\u003c\/strong\u003e. \u003c\/p\u003e\n\u003ch2\u003eIs the tube 4 oz or 5 oz?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e142 g\/5 oz\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eIs Redux Paste sterile?\u003c\/h2\u003e\n\u003cp\u003eNo. IFU identifies it as nonsterile. \u003c\/p\u003e\n\u003ch2\u003eIs Redux Paste bacteriostatic?\u003c\/h2\u003e\n\u003cp\u003eYes. It is bacteriostatic. This does not mean that the paste is sterile or that it disinfects the skin or equipment. \u003c\/p\u003e\n\u003ch2\u003eIs Redux Paste abrasive?\u003c\/h2\u003e\n\u003cp\u003eYes, it is a water-based abrasive paste. \u003c\/p\u003e\n\u003ch2\u003eIs it water-soluble?\u003c\/h2\u003e\n\u003cp\u003eYes. Redux Paste is water-soluble, and the IFU says residue can be removed with a moistened soft cloth. \u003c\/p\u003e\n\u003ch2\u003eCan Redux Paste be used for ECG or EKG?\u003c\/h2\u003e\n\u003cp\u003eYes. Routine ECG is one of its manufacturer-listed applications. \u003c\/p\u003e\n\u003ch2\u003eCan it be used for short-term monitoring?\u003c\/h2\u003e\n\u003cp\u003eYes. Short-term monitoring is specifically included in the current indication. \u003c\/p\u003e\n\u003ch2\u003eCan it be used for defibrillation?\u003c\/h2\u003e\n\u003cp\u003eYes, when the defibrillator, paddles, or electrodes specifically permit or require a separate conductive paste. Do not add it to pre-gelled multifunction pads unless directed by their instructions. \u003c\/p\u003e\n\u003ch2\u003eIs Redux Paste an adhesive?\u003c\/h2\u003e\n\u003cp\u003eIt does not identify Redux Paste as an adhesive. It will not hold electrodes in place.\u003c\/p\u003e\n\u003cp\u003eFor adhesive conductivity, compare \u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive Conductive Adhesive Gel\u003c\/a\u003e. For EEG cup electrodes, \u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 conductive paste \u003c\/a\u003eis a better choice. \u003c\/p\u003e\n\u003ch2\u003eIs it the same as Redux Gel?\u003c\/h2\u003e\n\u003cp\u003eNo. Redux Paste is abrasive, bacteriostatic, and indicated for short-term monitoring, ECG, and defibrillation. Redux Gel is non-abrasive and indicated for routine ECG and defibrillation. \u003c\/p\u003e\n\u003ch2\u003eIs it the same as Redux Creme?\u003c\/h2\u003e\n\u003cp\u003eNo. Redux Creme is a bacteriostatic conductive cream for routine ECG and is not indicated for defibrillation.\u003c\/p\u003e\n\u003ch2\u003eCan it be used for EEG cup electrodes?\u003c\/h2\u003e\n\u003cp\u003eRedux Paste is not specifically indicated as an adhesive neurodiagnostic cup electrode paste. \u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 Conductive Paste\u003c\/a\u003e is the more appropriate Balego product for EEG, evoked potentials, PSG, MSLT, and related non-gelled neurodiagnostic electrodes.\u003c\/p\u003e\n\u003ch2\u003eCan it be used for TENS or NMES?\u003c\/h2\u003e\n\u003cp\u003eTENS and NMES are not included in the current Redux Paste indications reviewed. Use the electrode and stimulation-device instructions to select an appropriate contact medium. \u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra 360 Electrode Gel\u003c\/a\u003e is specifically positioned for compatible TENS applications and conductive rubber or carbon electrodes. \u003c\/p\u003e\n\u003ch2\u003eCan Redux Paste be applied to broken skin?\u003c\/h2\u003e\n\u003cp\u003eNo. Parker limits it to external use on intact, unbroken skin. \u003c\/p\u003e\n\u003ch2\u003eHow is it removed?\u003c\/h2\u003e\n\u003cp\u003eParker says Redux products can be removed with a moistened soft cloth. \u003c\/p\u003e\n\u003ch2\u003eHow should it be stored?\u003c\/h2\u003e\n\u003cp\u003eProtect the product from direct sunlight and follow any additional instructions printed on the current tube or carton. \u003c\/p\u003e\n\u003ch2\u003eHow many tubes are in a manufacturer case?\u003c\/h2\u003e\n\u003cp\u003eParker packages ten 5 oz tubes per box and five boxes per case, for a total of 50 tubes per manufacturer's case. \u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e","brand":"Parker Laboratories, Inc.","offers":[{"title":"Default Title","offer_id":47299516268799,"sku":"67-05","price":9.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Parker_Labs_Redux_Electrolyte_Paste_67-05_5_oz_tube.jpg?v=1784831354","url":"https:\/\/balego-stores.myshopify.com\/products\/redux-electrolyte-paste","provider":"Balego","version":"1.0","type":"link"}