{"product_id":"signagel-electrode-gel","title":"SignaGel® Electrode Gel, 2 oz | ECG, EMG \u0026 Defibrillation","description":"\u003ch2\u003eParker SignaGel® Conductive Electrode Gel — 2 oz Tube\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel® Electrode Gel\u003c\/a\u003e is a highly conductive, multipurpose electrolyte gel. It is designed to improve electrical contact between intact skin and compatible electromedical electrodes during ECG\/EKG, EMG, biofeedback, and manufacturer-approved defibrillation procedures.\u003c\/p\u003e\n\u003cp\u003eThe smooth saline-style formula helps fill small gaps between the electrode and skin, supporting a consistent conductive interface. SignaGel is water-soluble, non-staining, and non-gritty, allowing it to spread evenly and wipe away with a moistened soft cloth after the procedure.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003e15-60 \u003c\/b\u003eis a compact \u003cstrong\u003e60 g \/ 2 oz tube\u003c\/strong\u003e with a see-through body and stand-up dispensing cap. It is a practical size for diagnostic rooms, treatment areas, emergency carts, mobile kits, rehabilitation departments, and clinical teaching laboratories. \u003c\/p\u003e\n\u003cp\u003eFor additional options, browse our \u003ca href=\"https:\/\/www.balego.com\/collections\/conductivity-gels-lotions\"\u003econductive gels, lotions, and contact media\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHighly conductive multipurpose electrode gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eParker Laboratories product number 15-60\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 60 g \/ 2 oz tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended by the manufacturer for ECG\/EKG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for EMG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for biofeedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended for compatible defibrillation procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSaline-style electrolyte formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater-soluble for convenient cleanup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-staining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-gritty texture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBacteriostatic formulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSee-through tube for checking the remaining quantity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStand-up cap for convenient dispensing and storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-flammable and non-corrosive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntended for external use on intact skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMade in the United States \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignaGel is non-sterile and bacteriostatic and states that it is intended for external use on intact, unbroken skin. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eQuick product specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eSignaGel detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSignaGel®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eParker Laboratories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct number\u003c\/td\u003e\n\u003ctd\u003e15-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eElectrically conductive electrode gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormula type\u003c\/td\u003e\n\u003ctd\u003eMultipurpose saline-style electrolyte gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube size\u003c\/td\u003e\n\u003ctd\u003e60 g \/ 2 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eNon-sterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTexture\u003c\/td\u003e\n\u003ctd\u003eNon-gritty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanup\u003c\/td\u003e\n\u003ctd\u003eWater-soluble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStaining\u003c\/td\u003e\n\u003ctd\u003eDescribed by manufacturer as non-staining\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicrobial characteristic\u003c\/td\u003e\n\u003ctd\u003eBacteriostatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-listed procedures\u003c\/td\u003e\n\u003ctd\u003eECG, defibrillation, biofeedback, and EMG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin preparation product\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound coupling gel\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended skin condition\u003c\/td\u003e\n\u003ctd\u003eIntact, unbroken skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParaben warning\u003c\/td\u003e\n\u003ctd\u003eDo not use with a known skin allergy to parabens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandling\u003c\/td\u003e\n\u003ctd\u003eNon-flammable and non-corrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eProtect from direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego SKU\u003c\/td\u003e\n\u003ctd\u003e15-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhat is SignaGel used for?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProcedure or need\u003c\/th\u003e\n\u003cth align=\"right\"\u003eIs SignaGel a suitable choice?\u003c\/th\u003e\n\u003cth\u003eImportant qualification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG\/EKG\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eUse when the electrode or ECG system instructions call for separate conductive gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMG\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eFollow the electrode and EMG equipment instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiofeedback\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eHelps create a conductive electrode-to-skin interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when specifically permitted\u003c\/td\u003e\n\u003ctd\u003eDo not place beneath modern pre-gelled pads unless the defibrillator instructions direct it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-gelled reusable electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003ePotentially\u003c\/td\u003e\n\u003ctd\u003eConfirm compatibility with the electrode and equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-gelled disposable electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUsually unnecessary\u003c\/td\u003e\n\u003ctd\u003eAdditional gel may weaken adhesion or contaminate the existing hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-duration patient monitoring\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eConsider \u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra® 360\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIts salt- and chloride-free STAY-WET® formula is positioned for longer contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode hold or temporary adhesion\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChoose \u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive®\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eSignaGel is conductive but not primarily adhesive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEEG cup-electrode placement\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChoose \u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20® Conductive Paste\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eTen20 provides a thicker adhesive paste for non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin preparation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChoose \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep® Skin Prep Gel\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNuPrep prepares the site and is not a leave-on electrode gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasound therapy\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUse dedicated ultrasound gel\u003c\/td\u003e\n\u003ctd\u003eElectrode gel and acoustic coupling gel are different product categories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eECG, defibrillation, biofeedback, and EMG. Use in any particular workflow remains subject to the electromedical device manufacturer’s instructions. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow SignaGel supports electrode contact\u003c\/h1\u003e\n\u003cp\u003eHuman skin is not perfectly flat. Dryness, surface texture, hair, or uneven electrode pressure can leave microscopic air gaps between an electrode and the body.\u003c\/p\u003e\n\u003cp\u003eBecause air conducts electricity poorly, these gaps may increase resistance or create inconsistent contact. Conductive gel fills small surface irregularities and creates a more continuous interface.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eContact problem\u003c\/th\u003e\n\u003cth\u003eHow conductive gel may help\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmall air gaps\u003c\/td\u003e\n\u003ctd\u003eGel fills irregular spaces between electrode and skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry contact surface\u003c\/td\u003e\n\u003ctd\u003eA moist conductive medium supports electrical transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUneven electrode pressure\u003c\/td\u003e\n\u003ctd\u003eGel helps distribute the conductive interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoisy physiological signal\u003c\/td\u003e\n\u003ctd\u003eBetter contact may reduce contact-related artifacts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInconsistent readings\u003c\/td\u003e\n\u003ctd\u003eA more uniform interface may improve repeatability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentrated or sharp sensation\u003c\/td\u003e\n\u003ctd\u003eComplete contact may reduce localized current concentration in compatible stimulation setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSignaGel should not be used to compensate for a damaged electrode, broken lead wire, incorrect placement, or incompatible equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eBacteriostatic does not mean sterile\u003c\/h1\u003e\n\u003cp\u003eSignaGel is described as \u003cstrong\u003ebacteriostatic\u003c\/strong\u003e, meaning its formulation is designed to inhibit bacterial growth in the product.\u003c\/p\u003e\n\u003cp\u003eIt does not mean that SignaGel:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSterilizes the skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisinfects an electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs appropriate for a sterile field\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMay be used on broken skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMay be used for invasive or percutaneous procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEliminates the need for infection-control procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignaGel is non-sterile and restricts use to intact, unbroken skin.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSignaGel vs. Spectra 360 vs. Tensive vs. Ten20\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel®\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra® 360\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive®\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20®\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eSaline conductive electrode gel\u003c\/td\u003e\n\u003ctd\u003eSalt- and chloride-free electrode gel\u003c\/td\u003e\n\u003ctd\u003eConductive adhesive gel\u003c\/td\u003e\n\u003ctd\u003eAdhesive conductive paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary function\u003c\/td\u003e\n\u003ctd\u003eImprove electrical contact\u003c\/td\u003e\n\u003ctd\u003eSupport conductive contact, especially during longer procedures\u003c\/td\u003e\n\u003ctd\u003eProvide conductivity plus temporary hold\u003c\/td\u003e\n\u003ctd\u003eHold non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTexture\u003c\/td\u003e\n\u003ctd\u003eSmooth gel\u003c\/td\u003e\n\u003ctd\u003eSmooth STAY-WET® gel\u003c\/td\u003e\n\u003ctd\u003eAdhesive gel\u003c\/td\u003e\n\u003ctd\u003eThick paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes, stronger paste holds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG\/EKG\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes, when permitted\u003c\/td\u003e\n\u003ctd\u003eProcedure-dependent\u003c\/td\u003e\n\u003ctd\u003eNot its primary use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMG\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eProcedure-dependent\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eSelected neurodiagnostic workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBiofeedback\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eProcedure-dependent\u003c\/td\u003e\n\u003ctd\u003eProcedure-dependent\u003c\/td\u003e\n\u003ctd\u003eNot primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd\u003eManufacturer-listed\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEEG cup electrodes\u003c\/td\u003e\n\u003ctd\u003eNot the primary choice\u003c\/td\u003e\n\u003ctd\u003eNot the primary choice\u003c\/td\u003e\n\u003ctd\u003eSelected uses\u003c\/td\u003e\n\u003ctd\u003eStrong fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-duration monitoring\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose\u003c\/td\u003e\n\u003ctd\u003eStronger fit\u003c\/td\u003e\n\u003ctd\u003eProcedure-dependent\u003c\/td\u003e\n\u003ctd\u003eNeurodiagnostic use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive carbon electrodes\u003c\/td\u003e\n\u003ctd\u003eWhen equipment permits\u003c\/td\u003e\n\u003ctd\u003eStrong fit\u003c\/td\u003e\n\u003ctd\u003eWhen temporary adhesion is useful\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKey distinction\u003c\/td\u003e\n\u003ctd\u003eBroad saline gel, including compatible defibrillation\u003c\/td\u003e\n\u003ctd\u003eSalt-free and chloride-free\u003c\/td\u003e\n\u003ctd\u003eConductivity plus adhesion\u003c\/td\u003e\n\u003ctd\u003eThick neurodiagnostic electrode paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOur \u003ca href=\"https:\/\/www.balego.com\/blogs\/which-conductive-contact-media-to-use\/signa-gel-vs-electrode-gel\"\u003eSignaGel vs. Electrode Gel guide\u003c\/a\u003e explains how procedure duration, salt content, adhesive requirements, electrode type, and defibrillation compatibility affect product selection. Spectra 360 is positioned as salt- and chloride-free and is not recommended for defibrillation, while Tensive is designed to add temporary adhesive performance. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSignaGel vs. Spectra 360\u003c\/h1\u003e\n\u003cp\u003eSignaGel and Spectra 360 are both electrode gels, but they should not be treated as identical products.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSelection factor\u003c\/th\u003e\n\u003cth align=\"right\"\u003eChoose SignaGel\u003c\/th\u003e\n\u003cth align=\"right\"\u003eChoose Spectra 360\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaline electrolyte gel is specified\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation appears in the equipment workflow\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when the equipment IFU allows\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG or EMG needs a general-purpose conductive gel\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes, when permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-duration contact is important\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eMay be used when directed\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eOften the stronger fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA salt-free and chloride-free formulation is required\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable carbon or conductive-rubber electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eCompatible when instructions allow\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSpecifically positioned for this use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact 2 oz tube\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarger 8.5 oz Balego option\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNot on this listing\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eConductive gel vs. adhesive gel vs. skin preparation\u003c\/h1\u003e\n\u003cp\u003eThese categories are frequently confused.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct category\u003c\/th\u003e\n\u003cth\u003eExample\u003c\/th\u003e\n\u003cth\u003ePrimary role\u003c\/th\u003e\n\u003cth align=\"right\"\u003eRemains during procedure?\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive electrode gel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eImprove electrical contact\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt-free electrode gel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra 360\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive contact without salt or chloride\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive adhesive gel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity plus temporary electrode hold\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive electrode paste\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFill and hold non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbrasive skin-prep gel\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePrepare skin and help lower impedance\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eExcess is removed before placement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-gelled hydrogel electrode\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tens-electrodes\"\u003eBalego TENS\/NMES\/FES Electrodes\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrode, gel, and adhesion combined\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eThe electrode remains attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSignaGel is not abrasive and is not intended to replace skin preparation. It also does not provide the same electrode-holding function as Tensive or Ten20.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCan SignaGel be used with TENS or NMES?\u003c\/h1\u003e\n\u003cp\u003eMany modern \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eTENS and NMES electrodes\u003c\/a\u003e already contain self-adhering conductive hydrogel. Additional gel is generally unnecessary and may reduce adhesion, make the pad slide, or contaminate its existing gel layer.\u003c\/p\u003e\n\u003cp\u003eSignaGel may be appropriate when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe TENS or NMES system uses non-gelled reusable electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe equipment manufacturer calls for a conductive saline gel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA compatible carbon-rubber electrode requires separate contact media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treating professional has specified SignaGel or an equivalent product.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor reusable non-adhesive options, compare our \u003ca href=\"https:\/\/www.balego.com\/products\/carbon-rubber-electrodes\"\u003eUni-Patch Carbon Rubber Electrodes\u003c\/a\u003e. Their product instructions require compatible conductive media or another approved attachment system.\u003c\/p\u003e\n\u003cp\u003eFor longer electrotherapy contact or reusable carbon electrodes, \u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra 360 Electrode Gel\u003c\/a\u003e may be a more specifically positioned option.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eDefibrillation use: an important distinction\u003c\/h1\u003e\n\u003cp\u003eDefibrillation is among SignaGel’s recommended applications. That does not mean gel should be added automatically to every defibrillation pad or paddle system.\u003c\/p\u003e\n\u003cp\u003eModern defibrillation equipment may use the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePre-gelled disposable pads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePaddles requiring a specified conductive medium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultifunction pacing and defibrillation electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProprietary pads that prohibit additional gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFollow the exact defibrillator or paddle instructions. Do not add SignaGel beneath a pre-gelled adhesive pad unless the equipment manufacturer expressly directs it.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow to use SignaGel\u003c\/h1\u003e\n\u003cp\u003eThe amount and placement of gel depend on the electrode and electromedical equipment. Always follow the equipment instructions.\u003c\/p\u003e\n\u003ch2\u003e1. Confirm compatibility\u003c\/h2\u003e\n\u003cp\u003eVerify that the procedure, electrode, and equipment call for a conductive electrode gel. Do not substitute SignaGel when the instructions specify a sterile gel, adhesive paste, ultrasound gel, or another dedicated product.\u003c\/p\u003e\n\u003ch2\u003e2. Inspect the skin\u003c\/h2\u003e\n\u003cp\u003eUse only on intact, unbroken skin.\u003c\/p\u003e\n\u003cp\u003eDo not apply over:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOpen wounds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAbrasions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBurns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActive rashes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInfected skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOther compromised tissue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e3. Check the product\u003c\/h2\u003e\n\u003cp\u003eDo not use the tube if:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe package is damaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe cap or seal is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContamination is visible or suspected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe gel has an abnormal appearance or consistency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe product is beyond its labeled expiration date.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e4. Avoid contaminating the tube\u003c\/h2\u003e\n\u003cp\u003eDo not allow the dispensing tip to contact the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe patient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStaff members\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsed electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment surfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContaminated gloves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDispense the gel without touching the application site.\u003c\/p\u003e\n\u003ch2\u003e5. Apply as directed\u003c\/h2\u003e\n\u003cp\u003eUse the quantity specified by the equipment or electrode instructions. Apply enough to establish contact without using so much that the electrode moves or gel spreads beyond the intended area.\u003c\/p\u003e\n\u003ch2\u003e6. Complete the procedure\u003c\/h2\u003e\n\u003cp\u003eOperate the ECG, EMG, biofeedback, defibrillation, or other compatible equipment according to its instructions.\u003c\/p\u003e\n\u003ch2\u003e7. Remove the gel\u003c\/h2\u003e\n\u003cp\u003eSignaGel is water-soluble and may be removed using a moistened soft cloth.\u003c\/p\u003e\n\u003ch2\u003e8. Recap and store\u003c\/h2\u003e\n\u003cp\u003eClose the cap after dispensing and protect the tube from direct sunlight.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eSafety and handling\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety topic\u003c\/th\u003e\n\u003cth\u003eManufacturer-based guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterility\u003c\/td\u003e\n\u003ctd\u003eSignaGel is non-sterile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin condition\u003c\/td\u003e\n\u003ctd\u003eExternal use only on intact, unbroken skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParaben allergy\u003c\/td\u003e\n\u003ctd\u003eDo not use on patients with a known skin allergy to parabens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDamaged package\u003c\/td\u003e\n\u003ctd\u003eDiscard if the package is damaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuspected contamination\u003c\/td\u003e\n\u003ctd\u003eDiscard the product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube-tip hygiene\u003c\/td\u003e\n\u003ctd\u003eDo not let the tip touch patients, staff, electrodes, or instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice compatibility\u003c\/td\u003e\n\u003ctd\u003eFollow the electromedical equipment instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanup\u003c\/td\u003e\n\u003ctd\u003eRemove with a moistened soft cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandling\u003c\/td\u003e\n\u003ctd\u003eNo special handling required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammability\u003c\/td\u003e\n\u003ctd\u003eDescribed as non-flammable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion\u003c\/td\u003e\n\u003ctd\u003eDescribed as non-corrosive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eProtect from direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eFollow applicable rules for non-hazardous waste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat is SignaGel?\u003c\/h2\u003e\n\u003cp\u003eSignaGel is a multipurpose electrically conductive electrode gel manufactured by Parker Laboratories. It is used to improve contact between intact skin and compatible electromedical electrodes.\u003c\/p\u003e\n\u003ch2\u003eWhat procedures is SignaGel recommended for?\u003c\/h2\u003e\n\u003cp\u003eECG, defibrillation, biofeedback, and EMG. \u003c\/p\u003e\n\u003ch2\u003eIs SignaGel sterile?\u003c\/h2\u003e\n\u003cp\u003eNo. It is a non-sterile electrode gel.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel bacteriostatic?\u003c\/h2\u003e\n\u003cp\u003eYes. Bacteriostatic means that the formulation helps inhibit bacterial growth in the product. It does not make the product sterile or disinfect the skin.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel water-soluble?\u003c\/h2\u003e\n\u003cp\u003eYes. The manufacturer directs users to remove it with a moistened soft cloth.\u003c\/p\u003e\n\u003ch2\u003eDoes SignaGel stain?\u003c\/h2\u003e\n\u003cp\u003eParker Laboratories describes it as non-staining.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel gritty?\u003c\/h2\u003e\n\u003cp\u003eNo. It is described as non-gritty.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel adhesive?\u003c\/h2\u003e\n\u003cp\u003eNo. It improves conductivity but is not designed primarily to hold an electrode in place.\u003c\/p\u003e\n\u003cp\u003eFor conductivity with temporary adhesive hold, compare \u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive Conductive Adhesive Gel\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan SignaGel be used for ECG or EKG?\u003c\/h2\u003e\n\u003cp\u003eYes, when the ECG electrode or recording system calls for separate conductive gel. Pre-gelled disposable ECG electrodes generally do not require additional gel.\u003c\/p\u003e\n\u003cp\u003eBrowse our \u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003eECG and EKG monitoring electrodes\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eCan it be used for EMG?\u003c\/h2\u003e\n\u003cp\u003eYes. EMG is a manufacturer-listed application.\u003c\/p\u003e\n\u003ch2\u003eCan it be used for biofeedback?\u003c\/h2\u003e\n\u003cp\u003eYes. Biofeedback is included in its indications.\u003c\/p\u003e\n\u003ch2\u003eCan it be used for defibrillation?\u003c\/h2\u003e\n\u003cp\u003eDefibrillation is manufacturer-listed, but the defibrillator or paddle instructions determine whether separate gel is appropriate. Do not add it automatically to pre-gelled defibrillation pads.\u003c\/p\u003e\n\u003ch2\u003eCan SignaGel be used with TENS?\u003c\/h2\u003e\n\u003cp\u003eOnly when the TENS electrode, device instructions, or healthcare professional calls for separate conductive gel. Do not add it routinely to self-adhesive hydrogel pads.\u003c\/p\u003e\n\u003ch2\u003eCan it be used with carbon-rubber electrodes?\u003c\/h2\u003e\n\u003cp\u003eIt may be used when the carbon electrode and stimulation device instructions permit a saline conductive gel. Compare \u003ca href=\"https:\/\/www.balego.com\/products\/carbon-rubber-electrodes\"\u003enon-gelled carbon rubber electrodes\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel the same as Spectra 360?\u003c\/h2\u003e\n\u003cp\u003eNo. SignaGel is a multipurpose saline-style electrolyte gel and includes defibrillation among its listed applications. Spectra 360 is salt- and chloride-free, uses a STAY-WET® formulation, and is not recommended for defibrillation. \u003c\/p\u003e\n\u003ch2\u003eIs SignaGel the same as Ten20?\u003c\/h2\u003e\n\u003cp\u003eNo. SignaGel is a smooth electrode gel. \u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 Conductive Paste\u003c\/a\u003e is a thicker adhesive paste used primarily to hold non-gelled neurodiagnostic electrodes.\u003c\/p\u003e\n\u003ch2\u003eIs SignaGel the same as NuPrep?\u003c\/h2\u003e\n\u003cp\u003eNo. \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e is mildly abrasive and used to prepare the skin. SignaGel remains at the electrode-to-skin interface during the procedure.\u003c\/p\u003e\n\u003ch2\u003eCan SignaGel replace ultrasound gel?\u003c\/h2\u003e\n\u003cp\u003eNo. Use an acoustic coupling gel recommended for the ultrasound system.\u003c\/p\u003e\n\u003ch2\u003eCan it be applied to broken skin?\u003c\/h2\u003e\n\u003cp\u003eNo. The current IFU limits use to intact, unbroken skin.\u003c\/p\u003e\n\u003ch2\u003eCan a patient with a paraben allergy use it?\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer instructs users not to apply SignaGel to patients with a known history of skin allergies to parabens. \u003c\/p\u003e\n\u003ch2\u003eHow should the tube be stored?\u003c\/h2\u003e\n\u003cp\u003eKeep it capped and protected from direct sunlight.\u003c\/p\u003e\n\u003ch2\u003eWhat should be done if the tube tip touches the patient?\u003c\/h2\u003e\n\u003cp\u003eThe IFU warns against allowing the tip to contact patients, staff, or instruments because this may contaminate the remaining gel. Follow the facility’s contamination and disposal policy.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy purchase SignaGel from Balego?\u003c\/h1\u003e\n\u003cp\u003eThe \u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel 2 oz Electrode Gel\u003c\/a\u003e is a compact option for clinics, diagnostic departments, emergency carts, rehabilitation facilities, teaching programs, and mobile treatment kits.\u003c\/p\u003e\n\u003cp\u003eWe also offer:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/spectra-360-electrode-gel\"\u003eSpectra 360 Salt-Free Electrode Gel\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive Conductive Adhesive Gel\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/ten20-conductive-paste\"\u003eTen20 Conductive Paste\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/carbon-rubber-electrodes\"\u003eCarbon Rubber Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/conductivity-gels-lotions\"\u003eConductive Gels, Lotions and Contact Media\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBalego’s \u003ca href=\"https:\/\/www.balego.com\/blogs\/which-conductive-contact-media-to-use\/signa-gel-vs-electrode-gel\"\u003eSignaGel vs. Electrode Gel Comparison Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct-selection assistance through the \u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eBalego contact page\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003e\u003c\/a\u003eFree U.S. shipping and quantity discounts at 3, 12, and 144 units. \u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Parker Laboratories, Inc.","offers":[{"title":"Default Title","offer_id":47299516072191,"sku":"15-60","price":7.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/SIGNAGEL-60G_TUBE.jpg?v=1783334530","url":"https:\/\/balego-stores.myshopify.com\/products\/signagel-electrode-gel","provider":"Balego","version":"1.0","type":"link"}