{"product_id":"ten20-conductive-paste","title":"Ten20® Conductive Paste | EEG, EP, PSG \u0026 MSLT Electrode Paste","description":"\u003cdiv dir=\"ltr\" id=\"model-response-message-contentr_e0d83f4a31a1f002\" class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\"\u003e\n\u003ch1\u003eTen20® Conductive Paste for EEG, PSG, and Neurodiagnostic Electrodes\u003c\/h1\u003e\n\u003cp\u003eTen20® Conductive Paste combines \u003cstrong\u003eelectrode adhesion and electrical conductivity\u003c\/strong\u003e in one non-drying paste for professional neurodiagnostic procedures. It is formulated for use with compatible, non-gelled electrodes during EEG examinations, evoked potential testing, polysomnography, multiple sleep latency testing, and related neuromonitoring workflows.\u003c\/p\u003e\n\u003cp\u003eUnlike a basic electrode gel, Ten20 has enough body and adhesive strength to help hold a cup electrode at the prepared site throughout the examination. Its washable formula is removed with warm water after testing, without requiring a harsh chemical adhesive remover\u003c\/p\u003e\n\u003cp\u003eTen20 comes in two clinical jar sizes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4 oz \/ 113 g jars — package of three\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e8 oz \/ 228 g jars — package of three\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTen20 Conductive Paste: Quick Product Details\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eProduct information\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eAdhesive conductive electrode paste\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWeaver and Company\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended electrode type\u003c\/td\u003e\n\u003ctd\u003eCompatible non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed procedures\u003c\/td\u003e\n\u003ctd\u003eEEG, evoked potentials, PSG, and MSLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormula behavior\u003c\/td\u003e\n\u003ctd\u003eWashable and non-drying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary function\u003c\/td\u003e\n\u003ctd\u003eHelps hold the electrode in place while providing a conductive interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 oz. product number\u003c\/td\u003e\n\u003ctd\u003e10-20-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 oz. product number\u003c\/td\u003e\n\u003ctd\u003e10-20-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego packaging\u003c\/td\u003e\n\u003ctd\u003eThree jars per package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleanup\u003c\/td\u003e\n\u003ctd\u003eWarm water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eKeep tightly closed and store at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLabeled shelf life\u003c\/td\u003e\n\u003ctd\u003eThree years, with expiration date marked on the packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural rubber latex\u003c\/td\u003e\n\u003ctd\u003eManufactured without natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImportant restriction\u003c\/td\u003e\n\u003ctd\u003eNot recommended for current-inducing electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose Ten20 Conductive Paste?\u003c\/h2\u003e\n\u003ch3\u003eAdhesion and conductivity in one step\u003c\/h3\u003e\n\u003cp\u003eTen20 is designed to fill the cup of a compatible neurodiagnostic electrode, establish electrical contact with the prepared skin, and help keep the electrode positioned during the examination.\u003c\/p\u003e\n\u003cp\u003eThis combination is particularly useful when an electrode must remain stable through the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePatient repositioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLonger recording periods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvernight sleep studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRepeated sleep-lab testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultichannel neurodiagnostic setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcedures in which an electrode interruption could disrupt the recording\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer describes Ten20 as balancing adhesion and conductivity intended to maintain electrode position while transmitting the electrical signal used by the technician or technologist. \u003c\/p\u003e\n\u003ch3\u003eNon-drying consistency\u003c\/h3\u003e\n\u003cp\u003eTen20 is designed to remain moist rather than drying rapidly during use. This helps make it suitable for examinations in which the electrode must remain attached longer than it would during a brief screening procedure.\u003c\/p\u003e\n\u003ch3\u003eWarm-water cleanup\u003c\/h3\u003e\n\u003cp\u003eThe paste is washable and can be removed with warm water. No harsh chemical remover is required under the manufacturer’s normal cleanup instructions. \u003c\/p\u003e\n\u003cp\u003eFor detailed hair, skin, clothing, equipment, and spill-cleanup recommendations, see our guide to \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/nuprep-ten20-storage-cleanup\"\u003eNuPrep and Ten20 storage, cleanup, and shelf life\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eIs Ten20 the Correct Product for Your Procedure?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProcedure or need\u003c\/th\u003e\n\u003cth align=\"right\"\u003eTen20 fit\u003c\/th\u003e\n\u003cth\u003eSelection guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEEG with reusable cup electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eExcellent fit\u003c\/td\u003e\n\u003ctd\u003eDesigned for compatible non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvoked potential testing\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eExcellent fit\u003c\/td\u003e\n\u003ctd\u003eProvides both conductive contact and electrode hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolysomnography\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eExcellent fit\u003c\/td\u003e\n\u003ctd\u003eUseful when electrodes must remain positioned during an extended sleep study\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiple sleep latency testing\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eExcellent fit\u003c\/td\u003e\n\u003ctd\u003eSupports repeated daytime sleep-study electrode workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther compatible neuromonitoring\u003c\/td\u003e\n\u003ctd align=\"right\"\u003ePotential fit\u003c\/td\u003e\n\u003ctd\u003eConfirm the electrode and procedure instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreparing skin before electrode placement\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNot a skin-prep product\u003c\/td\u003e\n\u003ctd\u003eUse an approved preparation method such as \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoutine gel-only ECG or EMG procedure\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUsually choose a conductive gel\u003c\/td\u003e\n\u003ctd\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel Electrode Gel\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive rubber or carbon electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUsually choose an electrode gel\u003c\/td\u003e\n\u003ctd\u003eConsider \u003ca href=\"https:\/\/www.balego.com\/products\/spectra%C2%AE-360-electrode-gel-60g-250g-8-5oz-tube\"\u003eSpectra 360 Electrode Gel\u003c\/a\u003e when compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTENS, NMES, EMS, or FES stimulation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDo not use Ten20 as the stimulation medium\u003c\/td\u003e\n\u003ctd\u003eTen20 is not recommended for current-inducing electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNot appropriate\u003c\/td\u003e\n\u003ctd\u003eUse only a defibrillation-compatible gel permitted by the equipment manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTen20 vs. Other Conductive Products\u003c\/h2\u003e\n\u003cp\u003e“Conductive paste,” “skin-prep gel,” “electrode gel,” and “conductive adhesive gel” describe different products. They should not automatically be substituted for one another.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003ePrimary job\u003c\/th\u003e\n\u003cth align=\"right\"\u003eAdhesive?\u003c\/th\u003e\n\u003cth\u003eTypical Balego use case\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTen20 Conductive Paste\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHolds and conducts with compatible non-gelled neurodiagnostic electrodes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eEEG, evoked potentials, PSG, and MSLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePrepares the skin and helps lower skin impedance before electrode placement\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003ePreparation before Ten20 and compatible monitoring electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tensive-conductive-adhesive-gel\"\u003eTensive Conductive Adhesive Gel\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides conductivity with temporary adhesive hold\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eCompatible EEG, EMG, and electromedical workflows calling for adhesive gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel Electrode Gel\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCreates a smooth conductive interface without paste-style electrode hold\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCompatible ECG, EMG, biofeedback and approved defibrillation procedures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/spectra%C2%AE-360-electrode-gel-60g-250g-8-5oz-tube\"\u003eSpectra 360 Electrode Gel\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eSalt-free conductive wetting gel\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCompatible electromedical and reusable carbon-electrode applications, excluding defibrillation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTen20 is the most appropriate choice in this group when the purchaser specifically needs \u003cstrong\u003epaste-style adhesion for a non-gelled neurodiagnostic electrode\u003c\/strong\u003e. It should not be selected merely because a procedure requires “something conductive.” Product selection must follow the connected electrode and equipment instructions. \u003c\/p\u003e\n\u003cp\u003eFor a more detailed explanation of the two-step neurodiagnostic workflow, read \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/ten20-vs-nuprep-when-to-use-each-product\"\u003eTen20 vs. NuPrep: When to Use Each Product\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eChoosing Between 4 oz and 8 oz Ten20 Jars\u003c\/h2\u003e\n\u003cp\u003eBoth Balego options contain the same Ten20 Conductive Paste and are packaged as three jars. Select the size according to procedure volume, storage practices, and expected inventory turnover.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBalego option\u003c\/th\u003e\n\u003cth\u003eManufacturer number\u003c\/th\u003e\n\u003cth\u003ePackage\u003c\/th\u003e\n\u003cth\u003eBest suited for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4 oz \/ 113 g jars\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-20-4\u003c\/td\u003e\n\u003ctd\u003eThree jars\u003c\/td\u003e\n\u003ctd\u003eLower-volume EEG clinics, mobile services, teaching labs and facilities that prefer smaller open containers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e8 oz \/ 228 g jars\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10-20-8\u003c\/td\u003e\n\u003ctd\u003eThree jars\u003c\/td\u003e\n\u003ctd\u003eHigh-volume EEG departments, sleep laboratories and multi-room neurodiagnostic programs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChoose the 4 oz jars when you:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003ePaste use is occasional or moderate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeveral rooms need separate smaller jars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe facility prefers faster inventory rotation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe product will be carried by a mobile technologist\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe department is evaluating Ten20 for the first time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the 8 oz jars when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEEG or sleep testing is performed frequently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMany electrodes are placed each day\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe department wants fewer jar changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeveral long-duration procedures are scheduled regularly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe facility has reliable dispensing and contamination-control procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTypical Professional Application Workflow\u003c\/h2\u003e\n\u003cp\u003eAlways follow the current Ten20 instructions, electrode instructions, facility infection-control policy, and equipment requirements.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrepare the site.\u003c\/strong\u003e Gently prepare intact skin using an approved method. The manufacturer identifies an abrasive preparation product such as \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e as one option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDispense the paste.\u003c\/strong\u003e Place only the amount needed on a clean working surface, such as an appropriate strip of surgical tape, rather than repeatedly contacting the bulk jar during placement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFill the cup.\u003c\/strong\u003e Fill the compatible bell-shaped cup electrode until it is slightly overfilled.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePosition the electrode.\u003c\/strong\u003e Place the electrode onto the prepared site and apply moderate pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure when necessary.\u003c\/strong\u003e Tape or a small piece of gauze may be used when additional fixation is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerify the contact.\u003c\/strong\u003e Confirm acceptable electrode impedance and signal quality according to the recording system and facility protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemove and clean.\u003c\/strong\u003e After the examination, remove the electrode and wash the remaining Ten20 from the skin or hair with warm water.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis workflow summarizes the manufacturer’s application instructions without replacing the current IFU or the connected equipment instructions.\u003c\/p\u003e\n\u003ch2\u003eImportant Use and Safety Information\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTopic\u003c\/th\u003e\n\u003cth\u003eGuidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin condition\u003c\/td\u003e\n\u003ctd\u003eApply only to intact skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen wounds\u003c\/td\u003e\n\u003ctd\u003eDo not use on or near open wounds or compromised skin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEye contact\u003c\/td\u003e\n\u003ctd\u003eAvoid contact with the eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccidental eye exposure\u003c\/td\u003e\n\u003ctd\u003eRinse with warm water for 10–15 minutes and do not rub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin sensitivity\u003c\/td\u003e\n\u003ctd\u003eUse additional caution in patients with sensitivity to cosmetics, lotions, adhesives, abrasives, conductive media or salts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnexpected skin response\u003c\/td\u003e\n\u003ctd\u003eRemove promptly if rash, redness, itching, swelling or another abnormal reaction develops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong-term placement\u003c\/td\u003e\n\u003ctd\u003eRemove the electrode and inspect the skin at least daily\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent-inducing electrodes\u003c\/td\u003e\n\u003ctd\u003eDo not use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eKeep the container tightly closed at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold exposure\u003c\/td\u003e\n\u003ctd\u003eAvoid prolonged cold and freezing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisposal\u003c\/td\u003e\n\u003ctd\u003eThe manufacturer does not require special disposal handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe patient should be instructed to report persistent redness, soreness, or swelling at an electrode site. The IFU notes that individual tolerance to topical products varies and that an adverse skin complaint should be addressed promptly.\u003c\/p\u003e\n\u003ch2\u003eStorage and Inventory Management\u003c\/h2\u003e\n\u003cp\u003eTen20 should be kept tightly closed when it is not being dispensed. Store it at room temperature and protect it from prolonged cold or freezing temperatures.\u003c\/p\u003e\n\u003cp\u003eEach manufacturer package and individual container carries an expiration date. The manufacturer describes a three-year shelf life when the product is stored appropriately. \u003c\/p\u003e\n\u003cp\u003ePractical inventory considerations include the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRotate stock by expiration date\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid leaving the jar open during electrode setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse a clean dispensing method\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow facility infection-prevention procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid returning dispensed paste to the jar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the container and paste before use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not use product that has been improperly stored or appears abnormal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNuPrep and Ten20's Storage, Cleanup, and Shelf Life address detailed storage and cleanup questions.\u003c\/p\u003e\n\u003ch2\u003eWho Commonly Purchases Ten20?\u003c\/h2\u003e\n\u003cp\u003eTen20 Conductive Paste is a practical supply for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHospital EEG departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent neurodiagnostic laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSleep laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeurology clinics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEpilepsy-monitoring units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMobile EEG providers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntraoperative or clinical neuromonitoring departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedical and allied-health teaching programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUniversity and clinical research laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities using reusable non-gelled cup electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitability depends on the procedure, electrode, recording equipment, and facility protocol rather than the department name alone.\u003c\/p\u003e\n\u003ch2\u003eProduct Highlights\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdhesive conductive paste\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntended for compatible non-gelled neurodiagnostic electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eListed for EEG, evoked potential, PSG, and MSLT procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHelps hold cup electrodes at the prepared site\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductive interface for signal acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWashable, non-drying formula\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoves with warm water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo harsh adhesive remover normally required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable from Balego in 4 oz and 8 oz jars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree jars per package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree-year labeled shelf life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpiration date and ingredient list on the packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufactured without natural rubber latex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot recommended for current-inducing electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is Ten20 Conductive Paste used for?\u003c\/h3\u003e\n\u003cp\u003eTen20 is used with compatible, non-gelled neurodiagnostic electrodes during EEG exams, evoked potential tests, PSG, and MSLT. It helps provide conductivity while holding the electrode in place.\u003c\/p\u003e\n\u003ch3\u003eIs Ten20 an EEG gel?\u003c\/h3\u003e\n\u003cp\u003eTen20 is more accurately described as an \u003cstrong\u003eadhesive conductive paste\u003c\/strong\u003e. It is thicker and provides more electrode hold than a basic non-adhesive electrode gel.\u003c\/p\u003e\n\u003ch3\u003eDoes Ten20 reduce electrode impedance?\u003c\/h3\u003e\n\u003cp\u003eTen20 provides the conductive connection between the prepared skin and electrode, but it is not the primary skin-abrasion product. When additional skin preparation is needed, use an approved method such as \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e according to professional instructions.\u003c\/p\u003e\n\u003ch3\u003eIs Ten20 the same as NuPrep?\u003c\/h3\u003e\n\u003cp\u003eNo. NuPrep is a mildly abrasive skin-preparation gel used before electrode placement. Ten20 is the conductive adhesive paste used with the electrode. See \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/ten20-vs-nuprep-when-to-use-each-product\"\u003eTen20 vs. NuPrep\u003c\/a\u003e for a complete comparison.\u003c\/p\u003e\n\u003ch3\u003eCan Ten20 be used for sleep studies?\u003c\/h3\u003e\n\u003cp\u003eYes. PSG and MSLT are included in the manufacturer’s listed neurodiagnostic applications.\u003c\/p\u003e\n\u003ch3\u003eCan Ten20 be used with reusable cup electrodes?\u003c\/h3\u003e\n\u003cp\u003eTen20 is intended for compatible non-gelled neurodiagnostic electrodes. The manufacturer’s application instructions specifically describe filling a bell-shaped cup electrode with a central opening.\u003c\/p\u003e\n\u003ch3\u003eDoes Ten20 dry out during an examination?\u003c\/h3\u003e\n\u003cp\u003eTen20 is a non-drying paste. Correct container handling and application remain important. \u003c\/p\u003e\n\u003ch3\u003eHow is Ten20 removed from hair?\u003c\/h3\u003e\n\u003cp\u003eRemove the electrodes and any larger clumps gently, then wash the area with warm water. For more detailed patient and facility cleanup recommendations, see our \u003ca href=\"https:\/\/www.balego.com\/blogs\/eeg-ecg-diagnostic-guides\/nuprep-ten20-storage-cleanup\"\u003eTen20 cleanup guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eCan Ten20 be used with TENS or NMES electrodes?\u003c\/h3\u003e\n\u003cp\u003eNo. The Ten20 instructions state that the product should not be used with current-inducing electrodes. Use electrodes and conductive media specifically authorized for the stimulation device.\u003c\/p\u003e\n\u003ch3\u003eCan Ten20 be used for defibrillation?\u003c\/h3\u003e\n\u003cp\u003eTen20 is not a defibrillation gel. When a compatible procedure requires a conductive gel, consider a product such as \u003ca href=\"https:\/\/www.balego.com\/products\/signagel-electrode-gel\"\u003eSignaGel Electrode Gel\u003c\/a\u003e only as permitted by the defibrillator and accessory instructions.\u003c\/p\u003e\n\u003ch3\u003eDoes Ten20 contain natural rubber latex?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer states that Ten20 is manufactured without the use of natural rubber latex.\u003c\/p\u003e\n\u003ch3\u003eWhat sizes?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTen20 10-20-4: three 4 oz \/ 113 g jars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTen20 10-20-8: three 8 oz \/ 228 g jars\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow long is Ten20 good for?\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer lists a three-year shelf life, with the expiration date printed on the box and individual containers. Always follow the expiration date on the product received. \u003c\/p\u003e\n\u003ch2\u003eCondensed Shopify Product Description\u003c\/h2\u003e\n\u003cp\u003eTen20® Conductive Paste is a washable, non-drying adhesive electrode paste that works with compatible non-gelled neurodiagnostic electrodes. It helps hold cup electrodes securely in position while providing the conductive interface needed during EEG, evoked potential, PSG, MSLT, and related neuromonitoring procedures.\u003c\/p\u003e\n\u003cp\u003eBalego offers Ten20 in three-packs of \u003cstrong\u003e4 oz \/ 113 g jars\u003c\/strong\u003e and \u003cstrong\u003e8 oz \/ 228 g jars\u003c\/strong\u003e. The paste is removed with warm water, is manufactured without natural rubber latex, and has a manufacturer-labeled three-year shelf life.\u003c\/p\u003e\n\u003cp\u003ePrepare the skin according to professional protocol—often using \u003ca href=\"https:\/\/www.balego.com\/products\/nuprep%C2%AE-skin-prep-gel-4oz-tube-pack-of-3-each\"\u003eNuPrep Skin Prep Gel\u003c\/a\u003e—then use Ten20 with the compatible electrode. Ten20 is not a skin-preparation gel and is not recommended for current-inducing electrodes.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Ten20","offers":[{"title":"4 oz \/ 113g  (Pack of 3 Jars)","offer_id":48796679307519,"sku":"10-20-4","price":34.95,"currency_code":"USD","in_stock":true},{"title":"8 oz \/ 228g (Pack of 3 Jars)","offer_id":48796679274751,"sku":"10-20-8","price":57.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Ten20_conductive_paste.jpg?v=1783337853","url":"https:\/\/balego-stores.myshopify.com\/products\/ten20-conductive-paste","provider":"Balego","version":"1.0","type":"link"}