{"product_id":"theratouch-sw1","title":"TheraTouch SW1 Portable Radial Shockwave Device","description":"\u003ch1\u003eTheraTouch® SW1 Portable Radial Pressure Wave Device\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eRichmar TheraTouch® SW1\u003c\/strong\u003e, model SW1000, is a professional radial pressure wave device designed for physical therapy, sports medicine, chiropractic, and rehabilitation clinics.\u003c\/p\u003e\n\u003cp\u003eThe compact system combines a touchscreen interface, ergonomic treatment handpiece, rechargeable battery, interchangeable applicators, and carrying case. Clinicians can begin with one of 11 body-region programs, adjust the preset parameters, build a treatment manually, or create a frequency-and-energy sweep program.\u003c\/p\u003e\n\u003cp\u003eThe SW1 is intended for the relief of minor muscle aches and pains, temporary increases in local circulation, and activation of connective tissue. It is a prescription medical device intended only for trained, qualified healthcare professionals. It is not a home-use shockwave machine.\u003c\/p\u003e\n\u003cp\u003eExplore additional professional systems in our \u003ca href=\"https:\/\/www.balego.com\/collections\/shockwave\"\u003eshockwave collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTheraTouch SW1 at a Glance\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTheraTouch SW1 specification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eProfessional radial pressure wave device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRichmar \/ TheraTouch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel and SKU\u003c\/td\u003e\n\u003ctd\u003eSW1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eLCD touchscreen, adjustment knob and shortcut buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e1–22 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy\u003c\/td\u003e\n\u003ctd\u003e60–185 mJ at the applicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate energy display\u003c\/td\u003e\n\u003ctd\u003e1–4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock-count setting\u003c\/td\u003e\n\u003ctd\u003e100–10,000 shocks in 100-shock increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment modes\u003c\/td\u003e\n\u003ctd\u003eBody-region Guide, Manual and Sweep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody-region presets\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom protocols\u003c\/td\u003e\n\u003ctd\u003eUp to 30 saved favorites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator sizes\u003c\/td\u003e\n\u003ctd\u003e15 mm, 20 mm and 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded applicators\u003c\/td\u003e\n\u003ctd\u003eSR 15 mm, CR 15 mm and CR 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional applicators\u003c\/td\u003e\n\u003ctd\u003eSR 20 mm, SR 35 mm and CR 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate maximum penetration\u003c\/td\u003e\n\u003ctd\u003eUp to 35 mm, according to the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable 22.2V, 2200 mAh lithium-ion module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery test performance\u003c\/td\u003e\n\u003ctd\u003eApproximately 20,000 shocks at 120 mJ and 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge time\u003c\/td\u003e\n\u003ctd\u003eNo more than approximately three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-unit weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.63 lb with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain-unit dimensions\u003c\/td\u003e\n\u003ctd\u003e11.46\" × 6.69\" × 4.78\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice warranty\u003c\/td\u003e\n\u003ctd\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory warranty\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended environment\u003c\/td\u003e\n\u003ctd\u003eProfessional clinic; room-to-room mobility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended user\u003c\/td\u003e\n\u003ctd\u003eTrained, qualified or licensed medical professional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe maximum available energy depends on the selected frequency. Energy can reach 185 mJ at lower frequencies, but the permitted maximum decreases as frequency rises above 10 Hz.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Choose the TheraTouch SW1?\u003c\/h2\u003e\n\u003ch3\u003eDedicated Radial Pressure Wave Platform\u003c\/h3\u003e\n\u003cp\u003eUnlike a multimodality device that adds stimulation or ultrasound, the SW1 is built specifically around radial pressure wave delivery.\u003c\/p\u003e\n\u003cp\u003eInside the handpiece, an electromagnetic coil accelerates a projectile toward the selected applicator. The impact creates a pressure pulse that enters the tissue through the applicator and coupling medium. The pressure energy is strongest near the applicator and spreads outward as it travels into the treatment area.\u003c\/p\u003e\n\u003cp\u003eThis dedicated design provides the clinician direct control over:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy or pressure level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal shock count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplicator type and diameter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNormal or Sweep output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment point and handpiece movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSaved custom protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTouchscreen with Physical Controls\u003c\/h3\u003e\n\u003cp\u003eThe SW1 combines an LCD touch display with an adjustment knob and dedicated shortcut buttons.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eInterface feature\u003c\/th\u003e\n\u003cth\u003ePractical benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen display\u003c\/td\u003e\n\u003ctd\u003eShows energy, frequency, shocks, applicator and handpiece status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment knob\u003c\/td\u003e\n\u003ctd\u003eAllows parameter changes without relying solely on touch controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual shortcut\u003c\/td\u003e\n\u003ctd\u003eOpens custom treatment setup directly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFavorites shortcut\u003c\/td\u003e\n\u003ctd\u003eOpens saved clinic protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettings shortcut\u003c\/td\u003e\n\u003ctd\u003eProvides access to language, energy units, brightness and volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock counters\u003c\/td\u003e\n\u003ctd\u003eSupports handpiece-use and maintenance tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy-unit selection\u003c\/td\u003e\n\u003ctd\u003eAllows the display to show mJ or bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe device supports multiple interface languages and lets the clinician adjust screen brightness and system volume.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e11 Body-Region Presets\u003c\/h2\u003e\n\u003cp\u003eThe SW1 includes preset starting parameters for 11 anatomical regions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePreset\u003c\/th\u003e\n\u003cth align=\"right\"\u003eManufacturer starting parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWrist\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 bar, 8 Hz, 1,500 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElbow\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.7 bar, 8 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnee\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShoulder\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.7 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeck\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 bar, 12 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThigh\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.2 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnkle\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpper back\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.5 bar, 12 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower back\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2.7 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower leg\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoot\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 bar, 10 Hz, 2,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese are body-region starting points—not diagnosis-specific prescriptions. The manual describes them as indicative parameters that may be adjusted according to the operator’s professional expertise and patient response. A preset name does not authorize treatment directly over the spinal column, lungs, large nerves, major vessels, or another contraindicated structure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eManual Mode\u003c\/h2\u003e\n\u003cp\u003eManual mode allows the clinician to build a treatment by selecting the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy in mJ or bar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency from 1–22 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock count from 100–10,000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplicator type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment technique\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCustom protocol name\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe resulting setup can be saved to the Favorites list for future use.\u003c\/p\u003e\n\u003ch3\u003eEnergy and Frequency Relationship\u003c\/h3\u003e\n\u003cp\u003eThe full 185 mJ output is not available at every frequency.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eFrequency\u003c\/th\u003e\n\u003cth align=\"right\"\u003eMaximum available energy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e1–10 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e185 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e11 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e180 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e12 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e170 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e13 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e160 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e14 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e150 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e15 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e140 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e16 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e130 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e17 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e120 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e18 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e110 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e19 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e100 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e20–22 Hz\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e90 mJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe device automatically limits the available energy according to the selected frequency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSweep Mode\u003c\/h2\u003e\n\u003cp\u003eSweep mode automatically cycles selected frequency and energy ranges from minimum to maximum and back again.\u003c\/p\u003e\n\u003cp\u003eThe clinician can define the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum energy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum energy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum frequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal number of shocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature provides a changing output pattern rather than holding energy and frequency at one fixed combination throughout the session.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSave Up to 30 Custom Protocols\u003c\/h2\u003e\n\u003cp\u003eThe SW1 can store up to 30 clinician-created programs in its Favorites menu.\u003c\/p\u003e\n\u003cp\u003eA saved protocol can retain the following selected items:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplicator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNormal or Sweep parameters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCustom protocol name\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese settings can help a clinic standardize recurring workflows while still requiring patient-specific screening and adjustment at each visit.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eIncluded SW1 Applicators\u003c\/h2\u003e\n\u003cp\u003eThree treatment applicators are supplied with the standard SW1 system.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplicator\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth align=\"right\"\u003eDiameter\u003c\/th\u003e\n\u003cth align=\"right\"\u003eIncluded?\u003c\/th\u003e\n\u003cth\u003eGeneral selection role\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR15-APP\u003c\/td\u003e\n\u003ctd\u003eSteel Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eSmaller standard steel contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCR15-APP\u003c\/td\u003e\n\u003ctd\u003eCompound Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e15 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eSmaller compound contact for sensitivity-focused treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCR20-APP\u003c\/td\u003e\n\u003ctd\u003eCompound Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd\u003eMedium compound contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR20-APP\u003c\/td\u003e\n\u003ctd\u003eSteel Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e20 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eMedium standard steel contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSR35-APP\u003c\/td\u003e\n\u003ctd\u003eSteel Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e35 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eBroad steel contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCR35-APP\u003c\/td\u003e\n\u003ctd\u003eCompound Round\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e35 mm\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eBroad compound contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCompound round applicators as options for patients who are more sensitive to treatment. The clinician should select the applicator based on the target area, treatment technique, tolerance,, and protocol—not simply use the largest tip available.\u003c\/p\u003e\n\u003ch3\u003e15 mm vs. 20 mm vs. 35 mm\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"right\"\u003eApplicator diameter\u003c\/th\u003e\n\u003cth\u003eGeneral consideration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e15 mm\u003c\/td\u003e\n\u003ctd\u003eSmaller contact surface for more localized treatment regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e20 mm\u003c\/td\u003e\n\u003ctd\u003eMedium contact surface for general-purpose clinical use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"right\"\u003e35 mm\u003c\/td\u003e\n\u003ctd\u003eLarger contact surface for broad muscle and soft-tissue regions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eApplicator diameter describes the contact surface. It does not by itself determine treatment depth or clinical effectiveness.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eWhat Comes with the TheraTouch SW1?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded component\u003c\/th\u003e\n\u003cth\u003eManufacturer part number\u003c\/th\u003e\n\u003cth align=\"right\"\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTheraTouch SW1 main unit\u003c\/td\u003e\n\u003ctd\u003eSW1000\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSW1 handpiece\u003c\/td\u003e\n\u003ctd\u003eSW1000-HP\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandpiece stand\u003c\/td\u003e\n\u003ctd\u003eSW1000-HPS\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 mm Steel Round applicator\u003c\/td\u003e\n\u003ctd\u003eSR15-APP\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 mm Compound Round applicator\u003c\/td\u003e\n\u003ctd\u003eCR15-APP\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 mm Compound Round applicator\u003c\/td\u003e\n\u003ctd\u003eCR20-APP\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator removal tool\u003c\/td\u003e\n\u003ctd\u003eSWAPP-RT\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShockwave O-ring service set\u003c\/td\u003e\n\u003ctd\u003eSWORINGS\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cord\u003c\/td\u003e\n\u003ctd\u003eDQ8000X\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable battery module\u003c\/td\u003e\n\u003ctd\u003eSW1BATT\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB user manual\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrying case\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eRechargeable Clinical Portability\u003c\/h2\u003e\n\u003cp\u003eThe removable lithium-ion battery supports movement between treatment rooms without keeping the unit connected continuously to a wall outlet.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePortability feature\u003c\/th\u003e\n\u003cth\u003eClinical value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.63 lb main unit\u003c\/td\u003e\n\u003ctd\u003eEasier room-to-room movement than a large floor-standing platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable battery\u003c\/td\u003e\n\u003ctd\u003eReduces dependence on an available wall outlet during treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. 20,000-shock test capacity\u003c\/td\u003e\n\u003ctd\u003eSupports multiple treatments under the specified 120 mJ\/10 Hz test condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaceable battery module\u003c\/td\u003e\n\u003ctd\u003eAllows the battery to be serviced independently from the main unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrying case\u003c\/td\u003e\n\u003ctd\u003eOrganizes the main unit, handpiece and accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact dimensions\u003c\/td\u003e\n\u003ctd\u003eFits smaller treatment rooms and clinic storage areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe SW1 is designed for clinical use and can be moved between rooms. It is \u003cstrong\u003enot intended for frequent transport between separate facilities and is not suitable for home use\u003c\/strong\u003e. The page should avoid describing it as a mobile home treatment or field-use device.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRadial Pressure Wave vs. Focused Shockwave\u003c\/h2\u003e\n\u003cp\u003eThe phrases “shockwave therapy” and “ESWT” are often used broadly, but radial and focused systems generate and distribute pressure differently.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eTheraTouch SW1 radial pressure wave\u003c\/th\u003e\n\u003cth\u003eFocused shockwave system\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy generation\u003c\/td\u003e\n\u003ctd\u003eA projectile impacts an applicator\u003c\/td\u003e\n\u003ctd\u003eElectrohydraulic, electromagnetic or piezoelectric source with focusing mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy pattern\u003c\/td\u003e\n\u003ctd\u003eStrongest near the applicator and spreads radially\u003c\/td\u003e\n\u003ctd\u003eConcentrated toward a defined focal region\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact method\u003c\/td\u003e\n\u003ctd\u003eHandpiece with interchangeable rigid applicator\u003c\/td\u003e\n\u003ctd\u003eTreatment head with acoustic coupling membrane or lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical depth behavior\u003c\/td\u003e\n\u003ctd\u003eEnergy diminishes as it travels from the applicator\u003c\/td\u003e\n\u003ctd\u003eEnergy converges toward a selected focal depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSW1 example\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon terminology\u003c\/td\u003e\n\u003ctd\u003eRPW, radial shockwave, rESWT\u003c\/td\u003e\n\u003ctd\u003eFocused ESWT, fESWT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe SW1 is properly described as a \u003cstrong\u003eradial pressure wave device\u003c\/strong\u003e. It should not be promoted as a focused shockwave system or as equivalent to one for every application. ISMST notes that “radial shockwave” is established clinical terminology even though radial systems technically generate unfocused pressure pulses.\u003c\/p\u003e\n\u003cp\u003eCurrent \u003ca href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/41651897\/\" target=\"_blank\" rel=\"noopener\"\u003ecomparative research\u003c\/a\u003e has not established one technology as universally superior across all tendon conditions; device choice should reflect the diagnosis, target depth, clinician training, and evidence for the intended application. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSW1 vs. Other Balego Clinical Modalities\u003c\/h2\u003e\n\u003cp\u003eThese systems deliver different forms of energy and should not be treated as interchangeable versions of the same therapy.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBalego device\u003c\/th\u003e\n\u003cth\u003eEnergy delivered\u003c\/th\u003e\n\u003cth\u003eMain workflow distinction\u003c\/th\u003e\n\u003cth\u003eConsider it when\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTheraTouch SW1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadial mechanical pressure pulses\u003c\/td\u003e\n\u003ctd\u003eHandheld impact-driven radial pressure wave treatment\u003c\/td\u003e\n\u003ctd\u003eA dedicated professional radial pressure wave system is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/theratouch-lx2-laser-therapy-device\"\u003eTheraTouch LX2 Laser\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eClass IIIb laser light\u003c\/td\u003e\n\u003ctd\u003eNon-impact photobiomodulation through laser applicators\u003c\/td\u003e\n\u003ctd\u003eA clinic wants low-level laser rather than mechanical pressure pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/theratouch%C2%AE-dx2-shortwave-diathermy\"\u003eTheraTouch DX2 Shortwave Diathermy\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eShortwave radiofrequency energy\u003c\/td\u003e\n\u003ctd\u003eControlled deep-tissue heating\u003c\/td\u003e\n\u003ctd\u003eThermal shortwave diathermy is the intended modality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/combocare-professional-e-stim-ultrasound-device\"\u003eComboCare E-Stim and Ultrasound\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eTherapeutic ultrasound and electrical stimulation\u003c\/td\u003e\n\u003ctd\u003eUltrasound, TENS, EMS, IFC, and Russian stimulation\u003c\/td\u003e\n\u003ctd\u003eA multimodality ultrasound\/e-stim platform is needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/theradot-deep-oscillation-therapy-device\"\u003eTHERADOT Deep Oscillation\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePulsed electrostatic field\u003c\/td\u003e\n\u003ctd\u003eGentle deep-oscillation or tissue-pumping workflow\u003c\/td\u003e\n\u003ctd\u003eA lower-impact oscillatory manual-treatment approach is preferred\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChoose the SW1 when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic specifically wants radial pressure wave capability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA dedicated rather than a combination device is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoom-to-room portability is important.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreset and custom programming are both needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple applicator materials and sizes are useful.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe practice is prepared to provide operator training, maintenance, and contraindication screening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic can support a professional shockwave service rather than an unsupervised home program.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConsider another modality when:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe intended treatment requires focused rather than radial energy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhotobiomodulation is the desired modality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeep heating is the treatment objective.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUltrasound or electrical stimulation is needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe patient cannot tolerate mechanical pressure pulses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic cannot provide trained professional operation and scheduled maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTreatment Workflow Overview\u003c\/h2\u003e\n\u003cp\u003eThis outline describes product operation rather than a diagnosis-specific treatment protocol.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eReview the patient’s history and confirm that radial pressure wave therapy is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScreen the patient for all contraindications and precautions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect and clean the intended treatment area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect the applicator and body-region preset or enter manual mode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a generous amount of legally marketed coupling gel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBegin at the minimum tolerable energy setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlace the applicator vertically against the treatment region.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncrease energy gradually while communicating with the patient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeliver the selected shock count using a stationary or moving technique.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor pain, skin response, and tolerance throughout treatment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStop or adjust treatment when the patient reports excessive pain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocument energy, frequency, shocks, applicator, and response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClean and inspect the applicator and handpiece after use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manual advises starting at the lowest energy, raising it gradually and using coupling gel to support energy transfer and reduce skin friction. Coupling gel is not included with the device.\u003c\/p\u003e\n\u003cp\u003eCompare compatible options in our \u003ca href=\"https:\/\/www.balego.com\/collections\/conductivity-gels-lotions\"\u003econductive gel and contact-media collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Treatment Documentation\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eField\u003c\/th\u003e\n\u003cth\u003eInformation to record\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice\u003c\/td\u003e\n\u003ctd\u003eTheraTouch SW1 \/ SW1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody region\u003c\/td\u003e\n\u003ctd\u003eExact location and side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMode\u003c\/td\u003e\n\u003ctd\u003eGuide, Manual or Sweep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreset\u003c\/td\u003e\n\u003ctd\u003eSelected body-region program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator\u003c\/td\u003e\n\u003ctd\u003eSR or CR and diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy\u003c\/td\u003e\n\u003ctd\u003emJ or bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003eHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock count\u003c\/td\u003e\n\u003ctd\u003eTotal delivered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnique\u003c\/td\u003e\n\u003ctd\u003eStationary, dynamic or combined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling medium\u003c\/td\u003e\n\u003ctd\u003eProduct used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient tolerance\u003c\/td\u003e\n\u003ctd\u003ePain level and need for adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin response\u003c\/td\u003e\n\u003ctd\u003eNone, redness, petechiae, bruising, swelling or irritation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmediate response\u003c\/td\u003e\n\u003ctd\u003eSymptoms, tenderness, motion or functional observation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePost-treatment instructions\u003c\/td\u003e\n\u003ctd\u003eActivity guidance and warning signs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandpiece counter\u003c\/td\u003e\n\u003ctd\u003eRecord when required by maintenance policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eMaintenance and Ownership Planning\u003c\/h2\u003e\n\u003cp\u003eShockwave systems contain mechanical consumable components. Clinics should consider long-term service requirements before purchasing.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eManufacturer guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHandpiece overhaul\u003c\/td\u003e\n\u003ctd\u003eApproximately every 1,000,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected handpiece life\u003c\/td\u003e\n\u003ctd\u003eApproximately 5,000,000 shocks with proper maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator service life\u003c\/td\u003e\n\u003ctd\u003eApproximately 1,000,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicator inspection\u003c\/td\u003e\n\u003ctd\u003eInspect at least weekly after approximately 300,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice expected service life\u003c\/td\u003e\n\u003ctd\u003eMinimum five years with normal use and proper maintenance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery performance decline\u003c\/td\u003e\n\u003ctd\u003eMay begin after approximately 200 full discharge cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous treatment block\u003c\/td\u003e\n\u003ctd\u003e6,000 shocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired break\u003c\/td\u003e\n\u003ctd\u003e15 minutes after a 6,000-shock treatment block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice warranty\u003c\/td\u003e\n\u003ctd\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessory warranty\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eApplicators, O-rings, projectiles, and guiding-tube components are consumable. The handpiece should be serviced only according to the manufacturer’s procedures or by authorized personnel.\u003c\/p\u003e\n\u003ch3\u003eWhy shock-count tracking matters\u003c\/h3\u003e\n\u003cp\u003eThe SW1 displays total shock counts for the main unit and handpiece. These counters can help the clinic:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSchedule handpiece overhauls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnticipate applicator replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlan maintenance expenses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrack device utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid unexpected downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocument preventive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIntended Use and Professional Restrictions\u003c\/h2\u003e\n\u003cp\u003eThe SW1 is intended for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRelief of minor muscle aches and pains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemporary increase in local blood circulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActivation of connective tissue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFederal law restricts the device to sale only by or on the order of a properly licensed practitioner. The SW1 is intended exclusively for trained, qualified medical professionals working in a clinical environment.\u003c\/p\u003e\n\u003cp\u003eThe presence of an anatomical preset does not establish that every diagnosis in that body region is appropriate for treatment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eContraindications and Safety\u003c\/h2\u003e\n\u003cp\u003eDo not use the SW1.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhere vascular disease is present in or near the treatment area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver or near a local infection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAround malignant or benign tumors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirectly on cartilage surfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNear the small facet joints of the spinal column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirectly over a pacemaker, analgesic pump or other electronic implant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhere mechanical vibration could damage tissue around certain metal implants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver or near an open wound\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAfter a fracture, torn muscle fiber or muscle tear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWith a local thrombosis or significant blood-clotting disorder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen anticoagulant or antiplatelet treatment creates unacceptable bleeding risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWithin six weeks after a local cortisone injection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDuring pregnancy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNear the head, large nerves, major vessels or spinal column\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOver the lungs, intercostal spaces, gastrointestinal area or other air-filled cavities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOn pediatric patients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOn an unconscious person or anyone unable to report pain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhere sensation or vasomotor function is impaired\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe operator must review the complete user manual rather than relying on this summary.\u003c\/p\u003e\n\u003ch3\u003ePossible Side Effects\u003c\/h3\u003e\n\u003cp\u003eTemporary effects can include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRedness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscomfort\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwelling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncreased pain or soreness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBruising or hematoma\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetechiae\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSkin irritation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSome effects can appear one or two days after treatment. The manufacturer instructs users not to repeat treatment until prior side effects have diminished.\u003c\/p\u003e\n\u003cp\u003eThe manual also recommends suitable hearing protection for the operator and patient because of treatment noise.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the TheraTouch SW1?\u003c\/h3\u003e\n\u003cp\u003eThe TheraTouch SW1 is Richmar’s professional radial pressure wave device, model SW1000. It uses a handheld applicator to transmit mechanically generated pressure pulses into the treatment area.\u003c\/p\u003e\n\u003ch3\u003eIs the SW1 a focused shockwave machine?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a radial pressure wave system. Its energy is generated at the handpiece applicator and spreads outward rather than being concentrated at a selected internal focal point.\u003c\/p\u003e\n\u003ch3\u003eIs radial pressure wave therapy still called shockwave therapy?\u003c\/h3\u003e\n\u003cp\u003eYes. “Radial shockwave therapy,” “radial ESWT,\" and “radial pressure wave therapy” are all used in clinical and commercial literature. \"Radial pressure wave\" is the most technically precise term.\u003c\/p\u003e\n\u003ch3\u003eHow deep does the SW1 reach?\u003c\/h3\u003e\n\u003cp\u003eRichmar lists an approximate maximum penetration depth of 35 mm. This is a manufacturer specification, not a guarantee that the same energy reaches every target at exactly that depth. Tissue composition, coupling, applicators, and technique can affect transmission. \u003c\/p\u003e\n\u003ch3\u003eHow many presets does it have?\u003c\/h3\u003e\n\u003cp\u003eThe SW1 has 11 body-region presets: wrist, elbow, knee, shoulder, neck, thigh, ankle, upper back, lower back, lower leg, and foot. Manual is a separate operating option.\u003c\/p\u003e\n\u003ch3\u003eCan the preset settings be changed?\u003c\/h3\u003e\n\u003cp\u003eYes. The clinician can modify the preset energy, frequency, and shock count according to professional judgment and patient tolerance.\u003c\/p\u003e\n\u003ch3\u003eHow many custom programs can be stored?\u003c\/h3\u003e\n\u003cp\u003eThe SW1 can save up to 30 custom protocols in Favorites.\u003c\/p\u003e\n\u003ch3\u003eWhat is sweep mode?\u003c\/h3\u003e\n\u003cp\u003eSweep mode cycles the selected energy and frequency from minimum to maximum and back again rather than maintaining one fixed combination.\u003c\/p\u003e\n\u003ch3\u003eWhat is the frequency range?\u003c\/h3\u003e\n\u003cp\u003eThe adjustable frequency range is 1–22 Hz.\u003c\/p\u003e\n\u003ch3\u003eWhat is the energy range?\u003c\/h3\u003e\n\u003cp\u003eThe range is 60–185 mJ, displayed alternatively as 1–4 bar. The highest available energy decreases at higher frequencies.\u003c\/p\u003e\n\u003ch3\u003eHow many shocks can be selected?\u003c\/h3\u003e\n\u003cp\u003eThe treatment control can be adjusted from 100 to 10,000 shocks in increments of 100. The manual requires a 15-minute break after a treatment block reaching 6,000 shocks.\u003c\/p\u003e\n\u003ch3\u003eWhich applicators are included?\u003c\/h3\u003e\n\u003cp\u003eThe standard package includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSR 15 mm Steel Round\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCR 15 mm Compound Round\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCR 20 mm Compound Round\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhich applicators are optional?\u003c\/h3\u003e\n\u003cp\u003eOptional choices include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSR 20 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSR 35 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCR 35 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat is the difference between SR and CR?\u003c\/h3\u003e\n\u003cp\u003eSR means Steel Round. CR means Compound Round. Richmar positions the compound applicators as options for patients who are more sensitive to treatment.\u003c\/p\u003e\n\u003ch3\u003eDoes the SW1 include gel?\u003c\/h3\u003e\n\u003cp\u003eNo. The manual states that coupling gel must be supplied separately.\u003c\/p\u003e\n\u003ch3\u003eIs the SW1 battery powered?\u003c\/h3\u003e\n\u003cp\u003eYes. It has a rechargeable and replaceable lithium-ion battery module.\u003c\/p\u003e\n\u003ch3\u003eHow long does the battery last?\u003c\/h3\u003e\n\u003cp\u003eRichmar markets approximately three hours of battery operation. The technical manual provides a more reproducible specification of approximately 20,000 shocks per full charge when operating at 120 mJ and 10 Hz. Actual performance varies with settings and battery condition. \u003c\/p\u003e\n\u003ch3\u003eHow long does charging take?\u003c\/h3\u003e\n\u003cp\u003eThe manual lists a charge time of no more than approximately three hours.\u003c\/p\u003e\n\u003ch3\u003eIs the SW1 suitable for mobile providers?\u003c\/h3\u003e\n\u003cp\u003eIt is designed to move between rooms within a clinical facility. The manual says it is not intended for frequent transport between separate facilities.\u003c\/p\u003e\n\u003ch3\u003eCan patients use it at home?\u003c\/h3\u003e\n\u003cp\u003eNo. It is a professional prescription device that is not suitable for home use.\u003c\/p\u003e\n\u003ch3\u003eHow often does the handpiece need service?\u003c\/h3\u003e\n\u003cp\u003eRichmar advises an overhaul after approximately every one million shocks. The listed expected handpiece service life is approximately five million shocks when maintenance intervals are observed.\u003c\/p\u003e\n\u003ch3\u003eHow long do the applicators last?\u003c\/h3\u003e\n\u003cp\u003eEach applicator is designed for approximately one million radial pressure waves. Richmar recommends weekly inspection after an applicator passes approximately 300,000 shocks.\u003c\/p\u003e\n\u003ch3\u003eWhat is the warranty?\u003c\/h3\u003e\n\u003cp\u003eThe main device carries a three-year limited warranty. Accessories carry a 12-month limited warranty.\u003c\/p\u003e\n\u003ch3\u003eDoes the SW1 replace ultrasound or laser?\u003c\/h3\u003e\n\u003cp\u003eNo. Radial pressure wave, ultrasound, laser, and shortwave diathermy deliver different forms of energy and have different clinical workflows, precautions, and treatment objectives.\u003c\/p\u003e\n\u003ch3\u003eDoes a preset guarantee that treatment is appropriate?\u003c\/h3\u003e\n\u003cp\u003eNo. The anatomical programs are starting parameters. The clinician must still establish the diagnosis, screen contraindications, and choose appropriate treatment parameters and placement.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eBest Buyer Fit\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinic or buyer\u003c\/th\u003e\n\u003cth\u003eWhy the SW1 may fit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical therapy clinic\u003c\/td\u003e\n\u003ctd\u003eAdds a dedicated radial pressure wave modality\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSports medicine practice\u003c\/td\u003e\n\u003ctd\u003eSupports professional soft-tissue and musculoskeletal workflows\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiropractic clinic\u003c\/td\u003e\n\u003ctd\u003eProvides a compact mechanical-pressure treatment platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAthletic training facility\u003c\/td\u003e\n\u003ctd\u003eBattery operation supports movement between treatment areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultidisciplinary rehabilitation clinic\u003c\/td\u003e\n\u003ctd\u003eComplements existing e-stim, ultrasound, laser or diathermy devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCash-pay specialty service\u003c\/td\u003e\n\u003ctd\u003eSupports development of a professionally delivered radial pressure wave service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-room clinic\u003c\/td\u003e\n\u003ctd\u003eCompact size and battery operation reduce dependence on one treatment room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClinic replacing a basic mechanical system\u003c\/td\u003e\n\u003ctd\u003eAdds touchscreen presets, sweep mode, and saved protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eWhy Buy the TheraTouch SW1 from Balego?\u003c\/h2\u003e\n\u003cp\u003eBalego supplies professional rehabilitation devices, treatment accessories, and contact media for clinics across the United States.\u003c\/p\u003e\n\u003cp\u003eOrdering the SW1 through Balego provides access to the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe complete SW1000 standard system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFree shipping across the USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBalego’s \u003ca href=\"https:\/\/www.balego.com\/price-guarantee\"\u003eBest Price Guarantee\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/shockwave\"\u003eShockwave equipment\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/conductivity-gels-lotions\"\u003eConductive gels and contact media\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/laser-therapy\"\u003eProfessional laser equipment\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/clinical-electrotherapy\"\u003eClinical electrotherapy systems\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/collections\/ultrasound-therapy-and-deep-oscillation\"\u003eUltrasound and deep-oscillation devices\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBalego product support through the \u003ca href=\"https:\/\/www.balego.com\/contact\"\u003econtact page\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe SW1 is a high-value professional device. Confirm practitioner requirements, clinical fit, training, maintenance, and accessory needs before ordering. \u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e","brand":"Richmar","offers":[{"title":"Default Title","offer_id":48760364761343,"sku":"SW1000","price":7695.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/TheraTouchSW1PortableShockwave.webp?v=1782936107","url":"https:\/\/balego-stores.myshopify.com\/products\/theratouch-sw1","provider":"Balego","version":"1.0","type":"link"}