{"product_id":"uni-tab-stimulating-electrodes","title":"Uni-Patch Uni-Tab Electrodes | Tab-Style TENS, NMES \u0026 FES Pads, 48 Pack","description":"\u003cdiv class=\"markdown markdown-main-panel tutor-markdown-rendering stronger enable-updated-hr-color\" id=\"model-response-message-contentr_edb7d55928734d17\" dir=\"ltr\"\u003e\n\u003ch2\u003eUni-Patch™ Uni-Tab® Tab-Style Stimulating Electrodes\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/uni-tab-stimulating-electrodes\"\u003eUni-Tab Stimulating Electrodes\u003c\/a\u003e are thin, self-adhering electrotherapy pads designed for compatible TENS, NMES, and FES systems that use a flat tab connection or an appropriate tab-electrode adapter.\u003c\/p\u003e\n\u003cp\u003eTheir low-profile, flexible construction conforms to ordinary body contours and makes the electrodes practical for physical therapy clinics, rehabilitation departments, chiropractic offices, sports-medicine programs, athletic-training rooms, teaching laboratories, and other settings that use electrotherapy electrodes frequently.\u003c\/p\u003e\n\u003cp\u003eEach package contains \u003cstrong\u003e48 electrodes\u003c\/strong\u003e, providing an economical alternative to individually packaged four-pad sets. Three sizes are available for compact, general-purpose, and broader-area placements.\u003c\/p\u003e\n\u003cp\u003eUnlike conventional pigtail electrodes, Uni-Tab pads do not contain a molded socket or attached lead. A compatible clip grips the electrode’s flat tab. Customers using standard pin-style TENS or NMES lead wires will generally need a compatible pin-to-clip adapter.\u003c\/p\u003e\n\u003cp\u003eThe Uni-Tab family is economical, thin, flexible, conformable, and suitable for trimming into other shapes and sizes when appropriate. Current product specifications list a carbon-film conductor, self-adhering gel, printed tape, tab connector, and release liner. \u003c\/p\u003e\n\u003ch3\u003eProduct highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eUni-Patch™ tab-style stimulating electrodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for compatible TENS, NMES, and FES systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree electrode sizes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e48 electrodes per package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlat tab connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThin, flexible, low-profile construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelf-adhering conductive gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCarbon-film conductive layer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHighly conformable design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for many clinical placement sites\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEconomical bulk packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick connection and disconnection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent distributor specifications classify them as reusable by one patient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNot made with natural rubber latex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMay be trimmed when permitted by current labeling and clinical protocol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdapter required for many conventional pin-lead systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUni-Tab electrodes are reusable for a single patient and not made with natural rubber latex. Follow the instructions printed on the package received, particularly if its reuse guidance differs. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eQuick product specifications\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eProduct detail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eUni-Patch™ Uni-Tab®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent portfolio\u003c\/td\u003e\n\u003ctd\u003eCardinal Health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eTab-style stimulating electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary modalities\u003c\/td\u003e\n\u003ctd\u003eCompatible TENS, NMES, and FES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFlat electrode tab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdhesive\u003c\/td\u003e\n\u003ctd\u003eSelf-adhering conductive gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive material\u003c\/td\u003e\n\u003ctd\u003eCarbon film\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther construction elements\u003c\/td\u003e\n\u003ctd\u003ePrinted tape and release liner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfile\u003c\/td\u003e\n\u003ctd\u003eThin, flexible, and low profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack quantity\u003c\/td\u003e\n\u003ctd\u003e48 electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable models\u003c\/td\u003e\n\u003ctd\u003e7020, 7022, and 7024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable sizes\u003c\/td\u003e\n\u003ctd\u003e1.25\" × 1.5\", 2\" × 2.25\", and 4\" × 2.25\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReuse\u003c\/td\u003e\n\u003ctd\u003eCurrent specifications classify as single-patient reusable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSharing between patients\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNatural rubber latex\u003c\/td\u003e\n\u003ctd\u003eCurrent distributor information states not made with natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional conductive gel\u003c\/td\u003e\n\u003ctd\u003eNormally unnecessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003eUsually required when the stimulator has conventional pin leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego bulk discount\u003c\/td\u003e\n\u003ctd\u003e10% off qualifying purchases of 10 or more units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eAvailable sizes\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eManufacturer number\u003c\/th\u003e\n\u003cth align=\"right\"\u003eSize\u003c\/th\u003e\n\u003cth align=\"right\"\u003eApproximate metric size\u003c\/th\u003e\n\u003cth\u003eShape description\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7020\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eET88045\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e1.25\" × 1.5\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e3.2 × 3.8 cm\u003c\/td\u003e\n\u003ctd\u003eSmall near-square pad\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7022\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eET88025\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2\" × 2.25\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e5.1 × 5.7 cm\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose near-square pad\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e7024\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eET88020\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e4\" × 2.25\"\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e10.2 × 5.7 cm\u003c\/td\u003e\n\u003ctd\u003eLarge rectangle\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWhich Uni-Tab size should you choose?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTreatment or purchasing need\u003c\/th\u003e\n\u003cth\u003eSuggested model\u003c\/th\u003e\n\u003cth\u003eWhy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact treatment site\u003c\/td\u003e\n\u003ctd\u003e7020\u003c\/td\u003e\n\u003ctd\u003eSmallest footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClosely spaced electrodes\u003c\/td\u003e\n\u003ctd\u003e7020\u003c\/td\u003e\n\u003ctd\u003eLeaves more room between pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral clinic inventory\u003c\/td\u003e\n\u003ctd\u003e7022\u003c\/td\u003e\n\u003ctd\u003eBalanced size for many standard placements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst Uni-Tab size to stock\u003c\/td\u003e\n\u003ctd\u003e7022\u003c\/td\u003e\n\u003ctd\u003eMost versatile of the three\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLarger muscle group\u003c\/td\u003e\n\u003ctd\u003e7024\u003c\/td\u003e\n\u003ctd\u003eCovers more skin surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBroad back, hip, or thigh placement\u003c\/td\u003e\n\u003ctd\u003e7024\u003c\/td\u003e\n\u003ctd\u003eLong rectangular footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeaching laboratory\u003c\/td\u003e\n\u003ctd\u003e7022\u003c\/td\u003e\n\u003ctd\u003eRepresentative general-purpose electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFacility wanting several placement options\u003c\/td\u003e\n\u003ctd\u003eAll three\u003c\/td\u003e\n\u003ctd\u003eCovers small, standard, and broad-area needs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChoose Model 7020 when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe available placement area is small.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA standard 2-inch pad is too large.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrodes must be positioned close together.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment instructions call for a compact electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou are replacing ET88045.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Model 7022 when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYou want the most versatile Uni-Tab size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinic needs a general-purpose tab electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou are replacing ET88025.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA 2\" × 2.25\" footprint fits the prescribed placement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou want a practical default size for clinic inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eChoose Model 7024 when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBroader electrode coverage is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment area is a larger muscle group.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA long rectangular electrode fits the placement better.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eYou are replacing ET88020.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe treatment instructions permit the larger surface area.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectrode size affects current density. At the same device setting, a smaller pad concentrates the output over less skin, while a larger pad distributes it across a broader surface. Return the device intensity to zero and increase it gradually whenever changing electrode size, brand, or placement.\u003c\/p\u003e\n\u003cp\u003eFor broader guidance, read our \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/buy-tens-electrodes-guide\"\u003eTENS Electrode Buying Guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhat is a tab-style electrode?\u003c\/h1\u003e\n\u003cp\u003eA tab electrode has a flat extension that provides the electrical connection. A compatible clip or alligator-style adapter grips the tab.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eHow it attaches\u003c\/th\u003e\n\u003cth\u003eCommon electrode type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlat tab\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe clip grips the extended tab\u003c\/td\u003e\n\u003ctd\u003eUni-Tab stimulating electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePigtail socket\u003c\/td\u003e\n\u003ctd\u003eA metal pin inserts into a short molded socket\u003c\/td\u003e\n\u003ctd\u003eMany reusable TENS and NMES pads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd\u003eThe lead snaps onto a metal stud\u003c\/td\u003e\n\u003ctd\u003eSelected stimulation and monitoring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic ECG tab\u003c\/td\u003e\n\u003ctd\u003eECG grabber grips a diagnostic tab\u003c\/td\u003e\n\u003ctd\u003eResting ECG electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProprietary connector\u003c\/td\u003e\n\u003ctd\u003eBrand-specific cable or pad\u003c\/td\u003e\n\u003ctd\u003eCertain wireless and legacy systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA stimulation tab electrode should not be confused with a diagnostic ECG tab. They may look similar, but their construction, connectors, equipment, electrical purpose, and labeling differ.\u003c\/p\u003e\n\u003cp\u003eOur \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/tens-nmes-electrode-connectors-pigtail-vs-tab\"\u003ePigtail vs. Tab Electrode Connector Guide\u003c\/a\u003e provides additional connector guidance. The most important purchasing step is confirming the electrode-end connection before ordering. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eDo Uni-Tab electrodes require an adapter?\u003c\/h1\u003e\n\u003cp\u003eUni-Tab electrodes require either the following or\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eA lead wire already equipped with a compatible tab clip, or\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA compatible \u003ca href=\"https:\/\/www.balego.com\/products\/uni-patch%E2%84%A2-adaptors-mw72147-model-770-080-in-pin-to-clip-red-bag-of-10\"\u003epin-to-clip adapter\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAn adapter is required to connect the Uni-Tab electrode to a conventional stimulator setup.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eExisting lead-wire end\u003c\/th\u003e\n\u003cth align=\"right\"\u003eDirect connection?\u003c\/th\u003e\n\u003cth\u003eLikely requirement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTab or alligator-style clip\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUsually\u003c\/td\u003e\n\u003ctd\u003eConfirm clip dimensions and device instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard 2 mm electrode pin\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eCompatible \u003ca href=\"https:\/\/www.balego.com\/products\/uni-patch%E2%84%A2-adaptors-mw72147-model-770-080-in-pin-to-clip-red-bag-of-10\"\u003epin-to-clip adapter\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePigtail socket\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDifferent lead wire or adapter system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnap\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDifferent lead wire or approved adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG grabber lead\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDo not assume compatibility\u003c\/td\u003e\n\u003ctd\u003eDiagnostic ECG leads are not automatically suitable for stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProprietary device lead\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eDevice-dependent\u003c\/td\u003e\n\u003ctd\u003eContact Balego or the device manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOur \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eelectrotherapy electrode collection\u003c\/a\u003e currently includes a red pin-to-clip option among its accessories. \u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy clinics choose Uni-Tab electrodes\u003c\/h1\u003e\n\u003ch2\u003eEconomical 48-electrode packaging\u003c\/h2\u003e\n\u003cp\u003eA 48-count package can be useful in high-volume clinical environments where small four-electrode retail packs create excess handling and packaging.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eClinical setting\u003c\/th\u003e\n\u003cth\u003ePotential advantage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical therapy clinic\u003c\/td\u003e\n\u003ctd\u003eEasier bulk stocking across treatment rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRehabilitation department\u003c\/td\u003e\n\u003ctd\u003eMultiple size choices for different placements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAthletic-training room\u003c\/td\u003e\n\u003ctd\u003eEconomical supply for frequent electrotherapy sessions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChiropractic office\u003c\/td\u003e\n\u003ctd\u003eTab-style option for compatible clinical stimulators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeaching laboratory\u003c\/td\u003e\n\u003ctd\u003eUseful for demonstrating electrode selection and connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHospital rehabilitation unit\u003c\/td\u003e\n\u003ctd\u003eSupports patient-specific electrode allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobile therapy service\u003c\/td\u003e\n\u003ctd\u003eCompact bulk supply when the lead system is compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eThin and conformable design\u003c\/h2\u003e\n\u003cp\u003eThe low-profile construction can follow curved or uneven body contours more easily than a thick foam pad. Tab-style electrodes are thin and flexible, and notes that they are popular for clinical applications. \u003c\/p\u003e\n\u003ch2\u003eQuick tab connection\u003c\/h2\u003e\n\u003cp\u003eThe flat tab permits quick attachment and removal when the correct clip is already connected to the stimulator lead wire. This can be convenient in treatment rooms where setup time and simple disconnection matter.\u003c\/p\u003e\n\u003ch2\u003eThree coverage choices\u003c\/h2\u003e\n\u003cp\u003eThe three sizes let a facility maintain one product family while covering compact, standard, and larger treatment regions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eCan Uni-Tab electrodes be trimmed?\u003c\/h1\u003e\n\u003cp\u003eThe thin, flexible design can be trimmed into other sizes and shapes. \u003c\/p\u003e\n\u003cp\u003eHowever, trimming changes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrode surface area\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent density\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShape and edge geometry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlacement options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe distance between the conductive area and tab\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow the electrode feels at a given intensity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse an unmodified factory size whenever possible. Trim an electrode only when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe current product labeling permits it.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe clinician or facility protocol allows it.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe tab and conductive pathway remain intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe resulting electrode is still large enough for the prescribed output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe device intensity is returned to zero and readjusted gradually.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDo not cut through the tab, create sharp corners, or use a trimmed electrode when its conductive layer, gel, or connection has been compromised.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eReuse and hygiene\u003c\/h1\u003e\n\u003cp\u003eWhen reuse is permitted:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAssign each electrode or set to one patient.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not share electrodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReturn electrodes to the supplied release liner.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlace them inside the resealable package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKeep the gel away from hair, lint, oil, and lotion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplace the electrode when adhesion or stimulation comfort declines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow facility infection-control procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\"Reusable\" does not mean \"indefinitely reusable.\" Electrode life depends on skin preparation, handling, treatment frequency, gel condition, environment, and storage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eHow to apply Uni-Tab electrodes\u003c\/h1\u003e\n\u003cp\u003eAlways follow the electrotherapy device instructions and clinician’s placement directions.\u003c\/p\u003e\n\u003ch2\u003e1. Confirm compatibility\u003c\/h2\u003e\n\u003cp\u003eBefore opening the package, verify:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe device supports the intended modality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe lead wire or adapter accepts a flat tab electrode.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe selected electrode size is appropriate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe lead wire and adapter are not damaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe electrode package and gel are in usable condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e2. Turn the device off\u003c\/h2\u003e\n\u003cp\u003eSet every channel to zero before connecting, applying, repositioning, or removing an electrode.\u003c\/p\u003e\n\u003ch2\u003e3. Prepare the skin\u003c\/h2\u003e\n\u003cp\u003eApply only to clean, dry, intact skin.\u003c\/p\u003e\n\u003cp\u003eRemove:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLotion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBody oil\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerspiration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMakeup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTopical pain products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoose debris\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e4. Connect the tab\u003c\/h2\u003e\n\u003cp\u003eSecure the approved clip to the electrode tab. The clip should grip the conductive tab area without touching the patient’s skin.\u003c\/p\u003e\n\u003ch2\u003e5. Remove the electrode from its liner\u003c\/h2\u003e\n\u003cp\u003eHandle it by the backing or non-gel edge. Avoid touching the conductive gel unnecessarily.\u003c\/p\u003e\n\u003ch2\u003e6. Apply the full surface\u003c\/h2\u003e\n\u003cp\u003eSmooth the pad onto the prescribed site so that the entire gel area contacts the skin.\u003c\/p\u003e\n\u003cp\u003eCheck for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLifted edges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFolded corners\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir pockets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHair beneath the gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcessive tension from the lead wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA clip positioned against the skin\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e7. Increase intensity gradually\u003c\/h2\u003e\n\u003cp\u003eBegin at zero and increase according to the device instructions and treatment plan.\u003c\/p\u003e\n\u003cp\u003eStop and inspect the electrode if stimulation feels\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSharp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBurning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePainful\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcentrated beneath one edge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntermittent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSubstantially different from the other pad\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e8. Remove and store\u003c\/h2\u003e\n\u003cp\u003eTurn the device off. Disconnect the clip and peel the electrode slowly from an edge.\u003c\/p\u003e\n\u003cp\u003eWhen reuse is permitted, return it to the release liner and reseal the package. Never pull the electrode from the skin by its tab or lead-wire clip.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhen should Uni-Tab electrodes be replaced?\u003c\/h1\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacement sign\u003c\/th\u003e\n\u003cth\u003eWhy it matters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel no longer adheres completely\u003c\/td\u003e\n\u003ctd\u003eIncomplete contact may concentrate stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEdges curl or repeatedly lift\u003c\/td\u003e\n\u003ctd\u003eEffective conductive area becomes smaller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel is dry, dirty, or contaminated\u003c\/td\u003e\n\u003ctd\u003eAdhesion and conductivity may decline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe tab is torn\u003c\/td\u003e\n\u003ctd\u003eThe connection may become unreliable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe carbon layer is exposed or damaged\u003c\/td\u003e\n\u003ctd\u003eCurrent distribution may be altered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe pad feels sharper at the same setting\u003c\/td\u003e\n\u003ctd\u003eContact may be uneven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput is intermittent\u003c\/td\u003e\n\u003ctd\u003eAn electrode, adapter, or lead may be damaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSkin irritation develops\u003c\/td\u003e\n\u003ctd\u003eStop use and assess the skin and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnother patient used the pad\u003c\/td\u003e\n\u003ctd\u003eDo not share patient-assigned electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThe modified pad no longer lies flat\u003c\/td\u003e\n\u003ctd\u003eReplace it with an intact factory-size electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eA stronger intensity setting should not be used to compensate for a worn or poorly adhering electrode.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eProduct comparison\u003c\/h1\u003e\n\u003ch2\u003eUni-Tab vs. other Balego electrotherapy electrodes\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/uni-tab-stimulating-electrodes\"\u003eUni-Tab Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/tens-electrodes\"\u003eBalego TENS\/NMES\/FES Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/intensity-2-inch-square-tens-electrodes\"\u003eInTENSity White Cloth Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.balego.com\/products\/classic-tens-electrodes\"\u003eUni-Patch Classic Electrodes\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFlat tab\u003c\/td\u003e\n\u003ctd\u003eSoft-molded pigtail socket\u003c\/td\u003e\n\u003ctd\u003ePigtail socket\u003c\/td\u003e\n\u003ctd\u003eSoft-molded pigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead requirement\u003c\/td\u003e\n\u003ctd\u003eTab clip or adapter\u003c\/td\u003e\n\u003ctd\u003eStandard compatible electrode pin\u003c\/td\u003e\n\u003ctd\u003eStandard compatible 2 mm pin\u003c\/td\u003e\n\u003ctd\u003eStandard compatible electrode pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage quantity\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable sizes\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eMultiple\u003c\/td\u003e\n\u003ctd\u003e2\" × 2\" only\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacking profile\u003c\/td\u003e\n\u003ctd\u003eThin printed tape\u003c\/td\u003e\n\u003ctd\u003eFlexible spun-lace\u003c\/td\u003e\n\u003ctd\u003eWhite cloth\u003c\/td\u003e\n\u003ctd\u003eSoft foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductive layer\u003c\/td\u003e\n\u003ctd\u003eCarbon film\u003c\/td\u003e\n\u003ctd\u003eConductive carbon film\u003c\/td\u003e\n\u003ctd\u003eFlexible carbon layer\u003c\/td\u003e\n\u003ctd\u003eSilver ink\/carbon film\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel\u003c\/td\u003e\n\u003ctd\u003eSelf-adhering conductive gel\u003c\/td\u003e\n\u003ctd\u003e0.040\" reusable hydrogel\u003c\/td\u003e\n\u003ctd\u003eSelf-adhering hydrogel\u003c\/td\u003e\n\u003ctd\u003eAloe hydrogel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrimmable\u003c\/td\u003e\n\u003ctd\u003eThe manufacturer describes as trimmable\u003c\/td\u003e\n\u003ctd\u003eNot recommended\u003c\/td\u003e\n\u003ctd\u003eNot recommended\u003c\/td\u003e\n\u003ctd\u003eNot recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest fit\u003c\/td\u003e\n\u003ctd\u003eHigh-volume tab-compatible clinics\u003c\/td\u003e\n\u003ctd\u003eEveryday pin-lead replacement use\u003c\/td\u003e\n\u003ctd\u003eForty-pad pin-lead bulk supply\u003c\/td\u003e\n\u003ctd\u003eComfort-focused premium four-pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMade-in-USA positioning\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eNot stated\u003c\/td\u003e\n\u003ctd\u003eCheck current packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eChoose Uni-Tab when:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eYour lead system accepts a flat tab or compatible clip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA clinic needs 48 electrodes per package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThin, conformable construction is a priority.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall, general-purpose, and larger rectangular sizes are needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControlled trimming is permitted by the product labeling and protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick tab connection is preferred.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch1\u003eUni-Tab vs. diagnostic ECG tab electrodes\u003c\/h1\u003e\n\u003cp\u003eThe word “tab” appears in both product categories, but they are not interchangeable.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eUni-Tab stimulating electrode\u003c\/th\u003e\n\u003cth\u003eDiagnostic ECG tab electrode\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd\u003eDeliver electrotherapy stimulation\u003c\/td\u003e\n\u003ctd\u003eRecord cardiac electrical activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical equipment\u003c\/td\u003e\n\u003ctd\u003eTENS, NMES, or FES unit\u003c\/td\u003e\n\u003ctd\u003eResting ECG\/EKG machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical direction\u003c\/td\u003e\n\u003ctd\u003eCurrent is delivered to the patient\u003c\/td\u003e\n\u003ctd\u003eA cardiac signal is received from the patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eCompatible stimulation clip or adapter\u003c\/td\u003e\n\u003ctd\u003eDiagnostic ECG grabber lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReusable\u003c\/td\u003e\n\u003ctd\u003eProduct-label dependent, single patient\u003c\/td\u003e\n\u003ctd\u003eNormally disposable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable substitute\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCustomers looking for cardiac diagnostic products should browse our \u003ca href=\"https:\/\/www.balego.com\/collections\/monitoring-ekg-ecg-electrodes\"\u003eECG and EKG electrode collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eFrequently asked questions\u003c\/h1\u003e\n\u003ch2\u003eWhat are Uni-Tab stimulating electrodes?\u003c\/h2\u003e\n\u003cp\u003eThey are thin, self-adhering electrotherapy electrodes with flat tab connections. They are intended for compatible TENS, NMES, and FES systems. \u003c\/p\u003e\n\u003ch2\u003eHow many electrodes are included?\u003c\/h2\u003e\n\u003cp\u003eEvery size contains 48 electrodes per package.\u003c\/p\u003e\n\u003ch2\u003eWhat sizes are available?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel 7020: 1.25\" × 1.5\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel 7022: 2\" × 2.25\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel 7024: 4\" × 2.25\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat is the most versatile size?\u003c\/h2\u003e\n\u003cp\u003eModel 7022, measuring 2\" × 2.25\", is the most practical general-purpose starting point for many clinical workflows.\u003c\/p\u003e\n\u003ch2\u003eWhat connector do they use?\u003c\/h2\u003e\n\u003cp\u003eThey use a flat tab connector. A compatible clip grips the tab.\u003c\/p\u003e\n\u003ch2\u003eWill they connect to standard TENS lead wires?\u003c\/h2\u003e\n\u003cp\u003eNot directly when those wires end in conventional electrode pins. An appropriate pin-to-clip adapter is generally required.\u003c\/p\u003e\n\u003ch2\u003eDo they fit every TENS unit?\u003c\/h2\u003e\n\u003cp\u003eNo. The device, lead wire, adapter, waveform, electrode size, and product instructions must all be compatible.\u003c\/p\u003e\n\u003ch2\u003eAre Uni-Tab electrodes reusable?\u003c\/h2\u003e\n\u003cp\u003eCurrent distributor specifications classify them as reusable for a single patient. Because some legacy wording is inconsistent, follow the current package instructions supplied with the electrodes. \u003c\/p\u003e\n\u003ch2\u003eCan several patients use the same electrodes?\u003c\/h2\u003e\n\u003cp\u003eNo. Keep reusable electrodes assigned to one person.\u003c\/p\u003e\n\u003ch2\u003eAre these disposable ECG tabs?\u003c\/h2\u003e\n\u003cp\u003eNo. They are stimulating electrodes for compatible electrotherapy systems.\u003c\/p\u003e\n\u003ch2\u003eCan the electrodes be trimmed?\u003c\/h2\u003e\n\u003cp\u003eThe thin, flexible design can be trimmed to other sizes and shapes. Do so only when allowed by the current labeling and clinical protocol, because reducing surface area increases current concentration.\u003c\/p\u003e\n\u003ch2\u003eCan I cut off the tab?\u003c\/h2\u003e\n\u003cp\u003eNo. The tab provides the electrical connection.\u003c\/p\u003e\n\u003ch2\u003eDo they require separate electrode gel?\u003c\/h2\u003e\n\u003cp\u003eNormally no. They are supplied with self-adhering conductive gel.\u003c\/p\u003e\n\u003ch2\u003eCan gel be added when they stop sticking?\u003c\/h2\u003e\n\u003cp\u003eDo not automatically add gel to a self-adhering electrode. Added gel can interfere with adhesion and alter contact. Replace an electrode that no longer provides complete, comfortable contact.\u003c\/p\u003e\n\u003ch2\u003eAre they made with natural rubber latex?\u003c\/h2\u003e\n\u003cp\u003eUni-Tab electrodes are not made with natural rubber latex.\u003c\/p\u003e\n\u003ch2\u003eCan Uni-Tab electrodes be used for TENS?\u003c\/h2\u003e\n\u003cp\u003eYes, when the TENS device and lead system are compatible.\u003c\/p\u003e\n\u003ch2\u003eCan they be used for NMES?\u003c\/h2\u003e\n\u003cp\u003eYes. NMES is a documented application. \u003c\/p\u003e\n\u003ch2\u003eCan they be used for FES?\u003c\/h2\u003e\n\u003cp\u003eYes, when the FES system permits this electrode type and connection. \u003c\/p\u003e\n\u003ch2\u003eCan they be used for interferential stimulation?\u003c\/h2\u003e\n\u003cp\u003eOnly when the interferential device’s instructions permit tab-style electrodes of the selected size. IFC is not the primary application listed on the specifications.\u003c\/p\u003e\n\u003ch2\u003eWhy does a smaller electrode feel stronger?\u003c\/h2\u003e\n\u003cp\u003eA smaller pad delivers the output over less skin area. At the same device setting, this can create greater current density and a more concentrated sensation.\u003c\/p\u003e\n\u003ch2\u003eWhy does stimulation feel sharp?\u003c\/h2\u003e\n\u003cp\u003ePossible causes include the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eLifted electrode edges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDry or contaminated gel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncorrect placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA damaged tab or adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcessive intensity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA pad that is too small\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncomplete skin contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTurn the device off before inspecting the setup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch1\u003eWhy purchase Uni-Tab electrodes from Balego?\u003c\/h1\u003e\n\u003cp\u003eWe offer all three Uni-Tab sizes on one consolidated page, allowing clinics to compare compact, general-purpose, and larger rectangular options before ordering.\u003c\/p\u003e\n\u003cp\u003eCustomers can also:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBrowse all \u003ca href=\"https:\/\/www.balego.com\/collections\/electrotherapy-electrodes\"\u003eElectrotherapy Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/tens-electrodes\"\u003eBalego TENS\/NMES\/FES Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/intensity-2-inch-square-tens-electrodes\"\u003eInTENSity 2\" Square Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompare \u003ca href=\"https:\/\/www.balego.com\/products\/classic-tens-electrodes\"\u003eUni-Patch Classic Electrodes\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead the \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/buy-tens-electrodes-guide\"\u003eTENS Electrode Buying Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead the \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\/tens-nmes-electrode-connectors-pigtail-vs-tab\"\u003ePigtail vs. Tab Connector Guide\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrowse Balego’s complete \u003ca href=\"https:\/\/www.balego.com\/blogs\/tens-electrode-guides\"\u003eTENS Electrode Guide library\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eContact Balego\u003c\/a\u003e for adapter and connector assistance\u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Cardinal Health","offers":[{"title":"1.25\" x 1.5\" Square (Model 7020)","offer_id":48791908188415,"sku":"ET88045","price":14.95,"currency_code":"USD","in_stock":true},{"title":"2\" x 2.25\" Square (Model 7022)","offer_id":48791908155647,"sku":"ET88025","price":17.95,"currency_code":"USD","in_stock":true},{"title":"4\" x 2.25\" Rectangle (Model 7024)","offer_id":48791908221183,"sku":"ET88020","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/Uni-Patch_Uni-Tab_stimulating_electrodes_48_pack.jpg?v=1784640779","url":"https:\/\/balego-stores.myshopify.com\/products\/uni-tab-stimulating-electrodes","provider":"Balego","version":"1.0","type":"link"}