{"product_id":"vitalstim-plus-parts","title":"VitalStim® Plus Accessories \u0026 Replacement Parts","description":"\u003ch1\u003eVitalStim® Plus Accessories \u0026amp; Replacement Parts\u003c\/h1\u003e\n\u003cp\u003eMaintain your VitalStim Plus system with genuine replacement accessories designed for the Chattanooga® VitalStim Plus electrotherapy and sEMG biofeedback system. Choose from snap lead wires, an sEMG reference lead wire, an operator hand switch, a protective rubber sleeve, a stylus, a tabletop stand, a battery door, or a reference EMG electrode.\u003c\/p\u003e\n\u003cp\u003eEach selection on this page is an \u003cstrong\u003eindividual VitalStim Plus accessory\u003c\/strong\u003e. The complete electrotherapy device is not included unless specifically identified as the system. To purchase the complete unit, visit the \u003ca href=\"https:\/\/www.balego.com\/products\/vitalstim-plus\"\u003eVitalStim Plus Electrotherapy and sEMG Biofeedback System\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eVitalStim Plus is a professional four-channel electrotherapy and two-channel surface electromyography system used in clinician-directed dysphagia rehabilitation. Because its stimulation, sEMG, reference electrode, and remote-control connections are system-specific, replacement parts should be selected by manufacturer number rather than appearance alone.\u003c\/p\u003e\n\u003ch2\u003eChoose the Correct VitalStim Plus Accessory\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth align=\"right\"\u003eManufacturer number\u003c\/th\u003e\n\u003cth\u003ePrimary function\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Snap Lead Wires\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e25-8080\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnect the device’s stimulation channels to compatible snap-style VitalStim electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Reference EMG Lead Wire\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8083\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects the reference EMG electrode to the device for sEMG measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Hand Switch\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8085\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides clinician-operated manual control of stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Stand\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8088\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports the device in an upright position during treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Stylus\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8089\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement stylus for navigating the device interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Rubber Sleeve\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8090\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtective replacement sleeve fitted around the handheld device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Battery Door\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8075\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReplacement cover for the AA battery compartment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim Plus Reference EMG Electrode\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e\u003cstrong\u003e13-8082\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePatient-contact reference electrode used during sEMG biofeedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eVitalStim Plus Snap Lead Wires — 25-8080\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Snap Lead Wires\u003c\/strong\u003e are replacement stimulation leads made specifically for the VitalStim Plus system. They connect the unit’s output channels to compatible VitalStim treatment electrodes.\u003c\/p\u003e\n\u003cp\u003eThe device uses color-coded channel connections to help clinicians organize the four stimulation channels:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel\u003c\/th\u003e\n\u003cth\u003eLead-wire color\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 1\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 2\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 3\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel 4\u003c\/td\u003e\n\u003ctd\u003eCranberry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSelect replacement snap lead wires when the original leads become damaged, intermittent, visibly worn, or unable to maintain a dependable connection. \u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Reference EMG Lead Wire — 13-8083\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eReference EMG Lead Wire\u003c\/strong\u003e connects the VitalStim Plus reference electrode to the device’s dedicated REF input. It is required when using the system’s surface EMG biofeedback functions.\u003c\/p\u003e\n\u003cp\u003eClinicians use the reference wire with a reference electrode attached to the patient for precise sEMG measurements. The reference lead is separate from the four color-coded stimulation-channel leads and should not be confused with a standard electrode cable. \u003c\/p\u003e\n\u003ch3\u003eReference lead wire vs. snap stimulation leads\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eReference EMG lead wire\u003c\/th\u003e\n\u003cth\u003eSnap lead wires\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e13-8083\u003c\/td\u003e\n\u003ctd\u003e25-8080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eDedicated REF input\u003c\/td\u003e\n\u003ctd\u003eStimulation channels 1–4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed for\u003c\/td\u003e\n\u003ctd\u003esEMG reference measurement\u003c\/td\u003e\n\u003ctd\u003eDelivery of electrical stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnects to\u003c\/td\u003e\n\u003ctd\u003eReference EMG electrode\u003c\/td\u003e\n\u003ctd\u003eVitalStim treatment electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterchangeable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eVitalStim Plus Reference EMG Electrode — 13-8082\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Reference EMG Electrode\u003c\/strong\u003e is the patient-contact reference electrode used with the reference EMG lead wire during surface electromyography and biofeedback treatment.\u003c\/p\u003e\n\u003cp\u003eThe reference electrode and reference lead work together:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eThe reference electrode is placed according to the clinician’s trained protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe electrode connects to the white reference EMG lead wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe lead wire connects to the VitalStim Plus REF port.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe system uses the reference connection to support accurate sEMG measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis electrode is not the same as the treatment electrodes used to deliver VitalStim or VMS stimulation. Part 13-8082 specifically acts as the replacement electrode that connects to the patient and permits sEMG functionality. \u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Hand Switch — 13-8085\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Hand Switch\u003c\/strong\u003e, also described in the manual as the operator remote switch, connects to the remote switch jack on the device. It gives the trained clinician direct manual control over stimulation during selected VitalStim or VMS treatment workflows.\u003c\/p\u003e\n\u003cp\u003eAfter manual mode is activated, stimulation begins while the clinician holds the remote button and stops when the button is released. The operator can also hold the switch while adjusting the selected channel intensity. The manufacturer states that the remote switch should be used only under the supervision of a physician or certified VitalStim user.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHand-switch action\u003c\/th\u003e\n\u003cth\u003eDevice response\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnect the switch\u003c\/td\u003e\n\u003ctd\u003eThe switch icon indicates that the accessory is connected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePress and release\u003c\/td\u003e\n\u003ctd\u003eActivates manual mode and returns intensity to 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePress and hold\u003c\/td\u003e\n\u003ctd\u003eBegins stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelease\u003c\/td\u003e\n\u003ctd\u003eStops stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold while adjusting channel control\u003c\/td\u003e\n\u003ctd\u003eAllows intensity adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eVitalStim Plus Stand — 13-8088\u003c\/h2\u003e\n\u003cp\u003eThe replacement \u003cstrong\u003eVitalStim Plus Stand\u003c\/strong\u003e supports the device in an upright viewing position during a clinical session. It can be useful when the clinician needs to monitor the display, operate the touchscreen, or position the unit where both clinician and patient can see treatment feedback.\u003c\/p\u003e\n\u003cp\u003eThis part is intended specifically for use with the VitalStim Plus device.\u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Stylus — 13-8089\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Stylus\u003c\/strong\u003e is a direct replacement for the stylus supplied for navigating the device’s color display and treatment interface.\u003c\/p\u003e\n\u003cp\u003eA dedicated stylus can help clinicians select treatment modes, enter information, adjust settings, and access patient-data or resource-library functions without relying on a finger for every screen selection. Part 13-8089 is identified by Chattanooga as the replacement stylus for the VitalStim Plus device. \u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Rubber Sleeve — 13-8090\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Rubber Sleeve\u003c\/strong\u003e fits around the handheld device as a replacement for the original protective sleeve. Replace it when the existing sleeve becomes damaged, loose, torn, or difficult to clean.\u003c\/p\u003e\n\u003cp\u003eThe rubber sleeve is shaped specifically for the VitalStim Plus housing and should not be replaced with a generic handheld-device cover.\u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Battery Door — 13-8075\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eVitalStim Plus Battery Door\u003c\/strong\u003e is the replacement cover for the device’s battery compartment. VitalStim Plus operates from four 1.5-volt AA batteries, and the operator manual instructs users to close the battery cover before turning on the unit.\u003c\/p\u003e\n\u003cp\u003eReplace the battery door if the original cover is lost, cracked, no longer closes securely, or cannot reliably protect the battery compartment. Part 13-8075 is identified as the dedicated VitalStim Plus battery-door replacement. \u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus Accessory Comparison\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth align=\"right\"\u003eCarries stimulation current\u003c\/th\u003e\n\u003cth align=\"right\"\u003eUsed for sEMG\u003c\/th\u003e\n\u003cth align=\"right\"\u003ePhysical support or protection\u003c\/th\u003e\n\u003cth align=\"right\"\u003eUsed directly by clinician\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnap lead wires\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChannels 1–2 may support sEMG depending on configuration\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference EMG lead wire\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo treatment stimulation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference EMG electrode\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo treatment stimulation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eApplied to patient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHand switch\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eControls stimulation\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStand\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSupports device\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStylus\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRubber sleeve\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eProtects device exterior\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery door\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eProtects battery compartment\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eReplacement Accessory or Complete VitalStim Plus System?\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eAccessories on this page\u003c\/th\u003e\n\u003cth\u003eComplete VitalStim Plus system\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd\u003eReplace a missing, worn, or damaged component\u003c\/td\u003e\n\u003ctd\u003eProvides the complete treatment platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice included\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer system number\u003c\/td\u003e\n\u003ctd\u003eIndividual numbers vary\u003c\/td\u003e\n\u003ctd\u003e5923-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFour-channel stimulation\u003c\/td\u003e\n\u003ctd\u003eNo, accessories only support the system\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTwo-channel sEMG\u003c\/td\u003e\n\u003ctd\u003eNo, reference accessories support this function\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim and VMS treatment modes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBluetooth screen mirroring\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient-data storage\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest choice when\u003c\/td\u003e\n\u003ctd\u003eThe clinic already owns a VitalStim Plus unit\u003c\/td\u003e\n\u003ctd\u003eA complete new system is required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003ePurchase the \u003ca href=\"https:\/\/www.balego.com\/products\/vitalstim-plus\"\u003ecomplete VitalStim Plus system\u003c\/a\u003e when you need the electrotherapy unit itself. Explore our broader \u003ca href=\"https:\/\/www.balego.com\/collections\/neuromuscular-stimulation\"\u003eNMES and EMS muscle-stimulator collection\u003c\/a\u003e for other neuromuscular stimulation systems and accessories.\u003c\/p\u003e\n\u003ch2\u003eCompatibility and Ordering Guidance\u003c\/h2\u003e\n\u003cp\u003eThese replacement parts are designed specifically for the \u003cstrong\u003eVitalStim Plus Electrotherapy System\u003c\/strong\u003e. Do not assume that a standard TENS lead wire, generic snap cable, general-purpose electrode, or accessory from an older VitalStim model will be compatible.\u003c\/p\u003e\n\u003cp\u003eThe VitalStim Plus operator manual states that powered muscle stimulators should be used only with the leads and electrodes recommended by the manufacturer. It also specifically warns against using accessories or techniques that were not designed for the system or approved through VitalStim certification training.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, confirm:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe manufacturer number printed on the original component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhether you need a stimulation lead or the separate reference EMG lead\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhether the electrode is a treatment electrode or an sEMG reference electrode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThat your device is the VitalStim \u003cstrong\u003ePlus\u003c\/strong\u003e system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhether the selected accessory is already included with a new system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe quantity and package configuration shown for the selected variant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor help confirming a part, \u003ca href=\"https:\/\/www.balego.com\/contact\"\u003econtact Balego\u003c\/a\u003e with the model number, accessory number, and a photograph of the connection when possible.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eDoes this product page include the VitalStim Plus device?\u003c\/h3\u003e\n\u003cp\u003eNo. This page is for selectable VitalStim Plus accessories and replacement parts. The complete device is sold separately on the \u003ca href=\"https:\/\/www.balego.com\/products\/vitalstim-plus\"\u003eVitalStim Plus Electrotherapy System page\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between the snap lead wires and the reference EMG lead wire?\u003c\/h3\u003e\n\u003cp\u003eThe snap lead wires connect the stimulation channels to VitalStim treatment electrodes. The reference EMG lead wire connects the dedicated reference electrode to the REF input for sEMG biofeedback. They perform different functions and are not interchangeable.\u003c\/p\u003e\n\u003ch3\u003eDo I need the reference EMG electrode to use sEMG?\u003c\/h3\u003e\n\u003cp\u003eThe operator manual instructs users to connect the reference wire with its electrode attached to the patient for precise sEMG measurements. The reference electrode and reference lead wire are separate components and should be ordered by their respective manufacturer numbers.\u003c\/p\u003e\n\u003ch3\u003eCan I use ordinary TENS lead wires with VitalStim Plus?\u003c\/h3\u003e\n\u003cp\u003eThey should not be assumed to be compatible or appropriate. VitalStim Plus uses device-specific connections and accessories, and the manufacturer directs users to use approved leads and electrodes designed for the system.\u003c\/p\u003e\n\u003ch3\u003eWhat does the VitalStim Plus hand switch do?\u003c\/h3\u003e\n\u003cp\u003eThe hand switch gives the trained clinician manual control over stimulation. In manual mode, holding the button begins stimulation, and releasing it stops stimulation.\u003c\/p\u003e\n\u003ch3\u003eAre VitalStim treatment electrodes included on this accessory page?\u003c\/h3\u003e\n\u003cp\u003eThis page currently lists the snap lead wires and reference EMG electrode but does not list the standard adult or small VitalStim treatment electrode packages shown in the manufacturer’s broader accessory catalog. Confirm the exact selected variant before ordering. \u003c\/p\u003e\n\u003ch3\u003eAre these accessories appropriate for home treatment?\u003c\/h3\u003e\n\u003cp\u003eVitalStim Plus is a prescription professional system intended for use by or under the order and supervision of a licensed healthcare professional. Accessories should be installed and used according to the operator manual, clinician training, and facility procedures.\u003c\/p\u003e\n\u003ch3\u003eWhere can I learn more about sEMG and dysphagia rehabilitation?\u003c\/h3\u003e\n\u003cp\u003eVisit our \u003ca href=\"https:\/\/www.balego.com\/blogs\/emg-electromyography\"\u003eEMG and muscle-biofeedback education center\u003c\/a\u003e or review Balego’s guide to \u003ca href=\"https:\/\/www.balego.com\/blogs\/which-modalities-to-use\/long-term-care-rehab-modalities-electrotherapy-ultrasound-nmes-laser-diathermy-amp-safe-patient-handling\"\u003eelectrotherapy and NMES in long-term care rehabilitation\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eProfessional-Use Notice\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus is a prescription professional electrotherapy and sEMG biofeedback system. Replacement accessories do not change the system’s intended use, indications, contraindications, warnings, or training requirements.\u003c\/p\u003e\n\u003cp\u003eInspect cables, connections, electrodes, housing components, and controls before each treatment. Discontinue use of accessories that are damaged, contaminated, excessively worn, intermittent, or unable to connect securely. Follow the complete VitalStim Plus operator manual and applicable clinical protocols.\u003c\/p\u003e","brand":"DJO, LLC \/ Enovis","offers":[{"title":"VitalStim Plus Snap Lead Wires — 25-8080","offer_id":48888736874751,"sku":"25-8080","price":59.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Reference sEMG Lead Wire — 13-8083","offer_id":48888736907519,"sku":"13-8083","price":16.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Operator Hand Switch — 13-8085","offer_id":48888736940287,"sku":"13-8085","price":49.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Protective Rubber Sleeve — 13-8090","offer_id":48888736973055,"sku":"13-8090","price":29.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Replacement Stylus — 13-8089","offer_id":48888737005823,"sku":"13-8089","price":16.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Device Stand — 13-8088","offer_id":48888737038591,"sku":"13-8088","price":29.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Battery Door — 13-8075","offer_id":48888737071359,"sku":"13-8075","price":16.95,"currency_code":"USD","in_stock":true},{"title":"VitalStim Plus Reference sEMG Electrode — 13-8082","offer_id":48888737104127,"sku":"13-8082","price":16.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/25-8080-VITALSTIM-PLUS-SNAP-LEAD-WIRES.webp?v=1784929153","url":"https:\/\/balego-stores.myshopify.com\/products\/vitalstim-plus-parts","provider":"Balego","version":"1.0","type":"link"}