{"product_id":"vitalstim-plus","title":"VitalStim® Plus Electrotherapy \u0026 sEMG Biofeedback System","description":"\u003ch1\u003eChattanooga VitalStim® Plus Electrotherapy \u0026amp; sEMG Biofeedback System\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eChattanooga VitalStim Plus Electrotherapy System\u003c\/strong\u003e combines four-channel neuromuscular electrical stimulation with two-channel surface electromyography, or sEMG, for clinician-directed treatment of oral-pharyngeal dysfunction and dysphagia. It gives qualified healthcare professionals a single platform for electrical stimulation, muscle-activity biofeedback, triggered stimulation, patient education, and treatment documentation.\u003c\/p\u003e\n\u003cp\u003eVitalStim Plus is designed specifically for swallowing rehabilitation rather than general-purpose TENS or portable muscle stimulation. Its treatment options include the dedicated VitalStim waveform, customizable VMS stimulation, standalone sEMG biofeedback, and sEMG-triggered stimulation. Bluetooth screen mirroring, an anatomical image library, instructional content, and exportable patient data help clinicians create an interactive therapy experience while tracking treatment performance. \u003c\/p\u003e\n\u003cp\u003eFor additional information about integrating NMES into rehabilitation settings, read our guide to \u003ca href=\"https:\/\/www.balego.com\/blogs\/which-modalities-to-use-guide\/long-term-care-rehab-modalities-electrotherapy-ultrasound-nmes-laser-diathermy-amp-safe-patient-handling\"\u003elong-term care rehabilitation modalities\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus at a Glance\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct detail\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eVitalStim® Plus Electrotherapy and sEMG Biofeedback System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eChattanooga \/ Enovis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer SKU\u003c\/td\u003e\n\u003ctd\u003e5923-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary application\u003c\/td\u003e\n\u003ctd\u003eClinician-directed dysphagia and swallowing-muscle rehabilitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStimulation channels\u003c\/td\u003e\n\u003ctd\u003eUp to 4 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esEMG channels\u003c\/td\u003e\n\u003ctd\u003eUp to 2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment options\u003c\/td\u003e\n\u003ctd\u003eVitalStim, VMS, sEMG and sEMG-triggered stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVitalStim output\u003c\/td\u003e\n\u003ctd\u003eConstant-current stimulation, 0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eBluetooth connection and screen mirroring to a compatible computer or tablet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData management\u003c\/td\u003e\n\u003ctd\u003eStore, display and export treatment information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eFour 1.5-volt AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.75 lb.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 in. wide × 1.4 in. deep × 6.2 in. high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntended user\u003c\/td\u003e\n\u003ctd\u003eQualified healthcare professional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory status\u003c\/td\u003e\n\u003ctd\u003ePrescription professional device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eA Specialized System for Dysphagia Rehabilitation\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus is designed to support muscle re-education of the swallowing musculature. The system brings several complementary tools into one portable clinical device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour-channel stimulation\u003c\/strong\u003e allows clinicians to apply stimulation through as many as four channels during a treatment session.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-channel sEMG biofeedback\u003c\/strong\u003e measures voluntary muscle activity and converts it into visual and audible feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThreshold-triggered stimulation\u003c\/strong\u003e can begin stimulation after the patient reaches a clinician-selected sEMG target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCustom VMS protocols\u003c\/strong\u003e allow adjustment of frequency, pulse duration, work time, rest time, ramping, and channel sequencing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePatient education resources\u003c\/strong\u003e include an anatomical library and videos demonstrating selected swallowing exercises and electrode-placement options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTreatment documentation\u003c\/strong\u003e allows patient-session data to be stored, reviewed, and exported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth screen mirroring\u003c\/strong\u003e can display treatment progress on a compatible computer or tablet, making biofeedback easier for both clinician and patient to view. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVitalStim Plus Treatment Modes\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTreatment mode\u003c\/th\u003e\n\u003cth\u003eHow it works\u003c\/th\u003e\n\u003cth\u003eClinical purpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVitalStim\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDelivers the dedicated VitalStim waveform through as many as four channels in co-contraction mode\u003c\/td\u003e\n\u003ctd\u003eMuscle re-education of swallowing musculature under qualified clinical supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides customizable symmetrical biphasic stimulation with adjustable treatment parameters and channel sequencing\u003c\/td\u003e\n\u003ctd\u003eAllows the clinician to build individualized stimulation protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003esEMG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeasures voluntary muscle activity and displays visual and audible biofeedback\u003c\/td\u003e\n\u003ctd\u003eHelps patients recognize, practice, and repeat targeted muscle activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003esEMG + Triggered Stimulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMonitors sEMG activity and initiates stimulation after a preset threshold is reached\u003c\/td\u003e\n\u003ctd\u003eAdds stimulation after the patient actively begins the exercise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStores stimulation and sEMG treatment information\u003c\/td\u003e\n\u003ctd\u003eSupports progress review and clinical documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnatomical Library\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDisplays dysphagia-related anatomy, pathology, and treatment images\u003c\/td\u003e\n\u003ctd\u003eSupports patient education and explanation of the therapy plan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe system’s interface provides direct access to VitalStim, VMS, sEMG, sEMG plus stimulation, patient data, an anatomical library, and device utilities.\u003c\/p\u003e\n\u003ch2\u003eHow sEMG Biofeedback Supports an Interactive Session\u003c\/h2\u003e\n\u003cp\u003eSurface electromyography measures the electrical activity produced during voluntary muscle contraction and relaxation. VitalStim Plus can display that activity on the device or a mirrored screen and convert it into audible feedback.\u003c\/p\u003e\n\u003cp\u003eInstead of asking the patient to perform an exercise without objective feedback, the clinician can establish a target and show the patient how much activity is being generated. This can help structure repetitions, encourage active participation, and provide measurable treatment information.\u003c\/p\u003e\n\u003cp\u003eDuring \u003cstrong\u003esEMG-triggered stimulation\u003c\/strong\u003e, the patient first attempts the prescribed swallowing exercise. When muscle activity reaches the selected threshold, the system changes to stimulation mode. The patient therefore initiates the activity rather than receiving stimulation without first attempting the movement.\u003c\/p\u003e\n\u003ch2\u003eVitalStim and VMS Waveform Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth align=\"right\"\u003eVitalStim waveform\u003c\/th\u003e\n\u003cth align=\"right\"\u003eVMS waveform\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform type\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSymmetrical square biphasic\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eSymmetrical biphasic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eConstant current\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eConstant current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntensity range\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0–25 mA\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase duration\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e300 microseconds\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eAdjustable from 60 to 300 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e80 pulses per second\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eAdjustable from 1–80 pulses per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel mode\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eCo-contraction\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eContinuous, reciprocal or co-contraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle time\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e57 seconds on, 1 second off\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eUser-defined on and off times from 1–99 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e2 seconds\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eAdjustable from 0 to 3 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTreatment time\u003c\/td\u003e\n\u003ctd align=\"right\"\u003e60 minutes\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eAdjustable from 1 to 240 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable channels\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChannels 1, 2, 3, and\/or 4\u003c\/td\u003e\n\u003ctd align=\"right\"\u003eChannels 1, 2, 3, and\/or 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTreatment parameters, electrode selection, electrode placement, patient screening, and treatment duration must be determined by a qualified practitioner following the manufacturer’s instructions and applicable professional requirements.\u003c\/p\u003e\n\u003ch2\u003eBuilt-In Patient Education and Treatment Tools\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus includes resources that can help clinicians explain the treatment process and keep patients engaged. Depending on the installed software and configuration, these resources include:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTool\u003c\/th\u003e\n\u003cth\u003ePractical benefit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwallowing-exercise videos\u003c\/td\u003e\n\u003ctd\u003eDemonstrate exercises such as the Masako exercise, Mendelsohn maneuver, and supraglottic maneuver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode-placement resources\u003c\/td\u003e\n\u003ctd\u003eProvide quick access to manufacturer-provided placement information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDysphagia anatomical library\u003c\/td\u003e\n\u003ctd\u003eHelps explain swallowing anatomy, pathology, and treatment concepts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen mirroring\u003c\/td\u003e\n\u003ctd\u003eDisplays live activity on a larger computer or tablet screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual and audible feedback\u003c\/td\u003e\n\u003ctd\u003eGives the patient immediate information about muscle effort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom protocols\u003c\/td\u003e\n\u003ctd\u003eLets the clinician save frequently used treatment configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient-data storage\u003c\/td\u003e\n\u003ctd\u003eSupports session review, progress tracking, and reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWho Is VitalStim Plus Designed For?\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus may be appropriate for professional environments that provide medically directed dysphagia evaluation and rehabilitation, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSpeech-language pathology departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDysphagia and swallowing clinics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHospitals and outpatient rehabilitation centers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSkilled nursing and long-term care facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeurological rehabilitation programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHead-and-neck rehabilitation programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcademic and clinical training environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVitalStim Plus is a professional healthcare product. VitalStim Therapy should be administered by appropriately trained clinicians who have completed the applicable certification process and who are working within their licensure, scope of practice, prescription requirements, and facility protocols. \u003c\/p\u003e\n\u003ch2\u003eVitalStim Plus vs. Other NMES Devices\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus should not be confused with a conventional portable NMES unit. General muscle stimulators may be appropriate for extremity muscle activation or other clinician-directed musculoskeletal programs, but they do not provide VitalStim’s dedicated dysphagia waveform, swallowing-focused interface, two-channel sEMG, threshold-triggered stimulation, anatomical library, or patient-data system.\u003c\/p\u003e\n\u003cp\u003eBrowse additional professional systems in our \u003ca href=\"https:\/\/www.balego.com\/collections\/clinical-electrotherapy\"\u003eclinical electrotherapy collection\u003c\/a\u003e, or compare portable options in the \u003ca href=\"https:\/\/www.balego.com\/collections\/neuromuscular-stimulation\"\u003eneuromuscular stimulation collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eStandard VitalStim Plus Accessories\u003c\/h2\u003e\n\u003cp\u003eThe manufacturer’s standard accessory list identifies the following components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFour color-coded snap lead wires for stimulation channels 1–4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhite sEMG reference lead wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator hand switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-wire clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDevice stand\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStylus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective rubber sleeve\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery door\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eElectrode style, size, placement, and compatibility are especially important for anterior-neck applications. Use only VitalStim electrodes and accessories specifically approved by the manufacturer and selected according to the prescribed clinical protocol. Contact \u003ca href=\"https:\/\/www.balego.com\/contact\"\u003eBalego product support\u003c\/a\u003e before ordering when compatibility is uncertain. \u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eVitalStim Plus\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e3.8 in. \/ 9.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e1.4 in. \/ 3.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e6.2 in. \/ 16 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 lb. \/ 0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input\u003c\/td\u003e\n\u003ctd\u003e6 volts from four 1.5-volt AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum patient output voltage\u003c\/td\u003e\n\u003ctd\u003e70 volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum VitalStim intensity\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esEMG measurement range\u003c\/td\u003e\n\u003ctd\u003e0.2–2,000 microvolts RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esEMG sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.1 microvolt RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStimulation channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esEMG channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical classification\u003c\/td\u003e\n\u003ctd\u003eType BF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e41°F–104°F \/ 5°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer number\u003c\/td\u003e\n\u003ctd\u003e5923-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalego reference\u003c\/td\u003e\n\u003ctd\u003eVITALSTIM-PLUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eImportant Safety and Professional-Use Information\u003c\/h2\u003e\n\u003cp\u003eVitalStim Plus is a prescription professional device and is not intended as a consumer self-treatment unit. The practitioner must review the complete operator manual, indications, contraindications, warnings, precautions, electrode requirements, and treatment instructions before use.\u003c\/p\u003e\n\u003cp\u003eStimulation should not be applied over the carotid sinus, cancerous lesions in the treatment area, or swollen, infected, inflamed, or eruptive skin areas. Particular caution is required for patients with pacemakers or other implanted electronic devices, suspected cardiac conditions, epilepsy, impaired sensation, or other listed risk factors. Patient selection is especially important in the management of dysphagia.\u003c\/p\u003e\n\u003cp\u003eOnly manufacturer-recommended lead wires, electrodes, and accessories should be used. This summary does not replace the complete VitalStim Plus instructions for use, professional training, medical evaluation, or clinician judgment.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the VitalStim Plus Electrotherapy System used for?\u003c\/h3\u003e\n\u003cp\u003eVitalStim Plus is a professional electrotherapy and sEMG biofeedback system designed for muscle re-education of the swallowing musculature in clinician-directed dysphagia rehabilitation. It combines a dedicated VitalStim waveform, customizable VMS stimulation, sEMG biofeedback, and sEMG-triggered stimulation.\u003c\/p\u003e\n\u003ch3\u003eHow many channels does VitalStim Plus have?\u003c\/h3\u003e\n\u003cp\u003eThe system provides up to four channels of electrical stimulation. Channels 1 and 2 may also be used for surface EMG measurement, giving the system two-channel sEMG capability.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between sEMG and electrical stimulation?\u003c\/h3\u003e\n\u003cp\u003esEMG measures electrical activity created by voluntary muscle contraction. Electrical stimulation delivers current through electrodes to activate targeted nerves and muscles. VitalStim Plus can use these separately or combine them so that stimulation begins when the patient reaches a selected sEMG threshold.\u003c\/p\u003e\n\u003ch3\u003eCan VitalStim Plus display treatment activity on a larger screen?\u003c\/h3\u003e\n\u003cp\u003eYes. Bluetooth screen-mirroring technology can project live treatment activity to a compatible computer or tablet. This can make visual biofeedback easier to see and can support patient participation during prescribed exercises. \u003c\/p\u003e\n\u003ch3\u003eCan VitalStim Plus save patient treatment data?\u003c\/h3\u003e\n\u003cp\u003eYes. Stimulation and sEMG treatment data can be stored, displayed, and exported to a computer for progress tracking and report generation. Clinicians must follow applicable patient-privacy and facility data-handling policies. \u003c\/p\u003e\n\u003ch3\u003eIs VitalStim Plus a TENS unit?\u003c\/h3\u003e\n\u003cp\u003eNo. VitalStim Plus is a specialized NMES and sEMG biofeedback system for dysphagia rehabilitation. It does not provide conventional TENS, interferential, or Russian stimulation modes.\u003c\/p\u003e\n\u003ch3\u003eCan a patient purchase VitalStim Plus for unsupervised home treatment?\u003c\/h3\u003e\n\u003cp\u003eVitalStim Plus is a prescription professional device intended for use under the prescription and supervision of a licensed healthcare practitioner. It should not be positioned as a general consumer or unsupervised home-use stimulator.\u003c\/p\u003e\n\u003ch3\u003eAre VitalStim electrodes included?\u003c\/h3\u003e\n\u003cp\u003eThe standard accessory list identifies the lead wires, sEMG reference lead, hand switch, stand, stylus, rubber sleeve, and battery door but does not identify treatment electrodes. Confirm the exact package contents and order approved VitalStim electrodes separately when required. \u003c\/p\u003e\n\u003ch3\u003eCan standard TENS electrodes be used with VitalStim Plus?\u003c\/h3\u003e\n\u003cp\u003eOnly electrodes and accessories specifically recommended for VitalStim Plus should be used. Standard general-purpose TENS or NMES electrodes should not be assumed to be suitable for anterior-neck or dysphagia applications.\u003c\/p\u003e\n\u003ch2\u003eOrder the VitalStim Plus System from Balego\u003c\/h2\u003e\n\u003cp\u003eThe Chattanooga VitalStim Plus gives qualified dysphagia professionals a portable system for four-channel stimulation, two-channel sEMG biofeedback, triggered stimulation, patient engagement, and treatment documentation.\u003c\/p\u003e\n\u003cp\u003eOrder the \u003cstrong\u003eVitalStim Plus Electrotherapy and sEMG Biofeedback System, SKU 5923-3\u003c\/strong\u003e, or \u003ca href=\"https:\/\/www.balego.com\/contact\"\u003econtact Balego\u003c\/a\u003e for assistance with product information, approved accessories, clinic purchasing, or compatibility questions. \u003ccode\u003e\u003c\/code\u003e\u003c\/p\u003e","brand":"DJO, LLC \/ Enovis","offers":[{"title":"Default Title","offer_id":48888656789759,"sku":"5923-3","price":3339.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0752\/0570\/5983\/files\/VITALSTIM-PLUS-ELECTROTHERAPY-SYSTEM.webp?v=1784926609","url":"https:\/\/balego-stores.myshopify.com\/products\/vitalstim-plus","provider":"Balego","version":"1.0","type":"link"}